On this episode of the Pipeliners Podcast, host Russel Treat is joined by Chris Carville of SCS Technologies to discuss various approaches to CO2 measurement, particularly in light of emerging federal initiatives and tax credits related to carbon dioxide.
Approaches to CO2 Measurement Show Notes, Links, and Insider Terms
- Chris Carville is the Senior Business Development Manager at SCS Technologies. Connect with Chris on LinkedIn.
- SCS Technologies is a leading provider of measurement equipment, environmental solutions, controls and automation solutions for hydrocarbon, water and refined products in the oilfield.
- API (American Petroleum Institute) represents all segments of America’s natural gas and oil industry. API has developed more than 800 standards to enhance operational and environmental safety, efficiency, and sustainability.
- API 6.X – Metering Systems for Mass Measurement of Supercritical Fluids- In 2022 the Committee on Liquid Measurement’s Emerging Issues meeting identified the need for industry guidance for the custody transfer of liquids transported in the supercritical state. The subsequent SR3 process scoped the need and approved resource allocation for work expected to lead to development of a new standard. The numbering placeholder for the expected document is API MPMS 6.X, which became the name of the workgroup formed to address this need.
- API 22.2 Standard (American Petroleum Institute – Manual of Petroleum Measurement Standards, Chapter 22 Section 2) defines testing and reporting protocol for the evaluation of differential pressure flow measurement devices.
- AGA (American Gas Association) represents companies delivering natural gas safely, reliably, and in an environmentally responsible way to help improve the quality of life for their customers every day. AGA’s mission is to provide clear value to its membership and serve as the indispensable, leading voice and facilitator on its behalf in promoting the safe, reliable, and efficient delivery of natural gas to homes and businesses across the nation.
- GPA or GPA Midstream Association is a voluntary industry organization composed of member companies that operate in the midstream sector of our industry. GPA Midstream sets standards for natural gas liquids; develops simple and reproducible test methods to define the industry’s raw materials and products; manages a worldwide cooperative research program; provides a voice for our industry on Capitol Hill; and is the go-to resource for technical reports and publications.
- Orifice Plate is a restrictive device installed in a pipeline for measuring the flow rate of liquids or gases by measuring the differential pressure created by across the restriction.
- Dense Phase Fluid Exists between above the critical point temperature and Cricondenbar pressure, but below the Cricondentherm temperature.
- Supercritical Fluid The fluid no longer exists in distinct gaseous and liquid phase. The viscosity is similar to a gas, but the density is similar to a liquid. It exists above a critical point pressure and temperature where no separate liquid and gas phases exist. However, the pressure is below what is required to compress it into a solid.
- PHMSA (Pipeline and Hazardous Materials Safety Administration) is responsible for providing pipeline safety oversight through regulatory rulemaking, NTSB recommendations, and other important functions to protect people and the environment through the safe transportation of energy and other hazardous materials.
- Upstream is the operation stage in the oil and gas industry that involves exploration and production.
- Midstream is the processing, storing, transporting and marketing of oil, natural gas, and natural gas liquids.
- Downstream is the process involved in converting oil and gas into the finished product, including refining crude oil into gasoline, natural gas liquids, diesel, and a variety of other energy sources. The closer an oil and gas company is to the process of providing consumers with petroleum products, the further downstream the company is said to be.
- CO2 Volume Calculator
- The Coriolis Effect describes the pattern of deflection taken by objects not firmly connected to the ground as they travel long distances around the Earth.
- Coriolis Meter is a mass flow meter that measures the mass flow rate of liquids and gases based on the Coriolis effect.
- Densitometer is an instrument used to measure the density of a fluid.
Approaches to CO2 Measurement Full Episode Transcript
Russel Treat: Welcome to the “Pipeliners Podcast,” “Episode 355,” sponsored by EnerSys Corporation, providers of POEMS, the Pipeline Operations Excellence Management System, operations and compliance software for the pipeline operator to address safety program management, control room management, and field operations. Find out more about POEMS at enersyscorp.com.
[background music]
Announcer: The Pipeliners Podcast, where professionals, Bubba geeks, and industry insiders share their knowledge and experience about technology, projects, and pipeline operations. Now, your host, Russel Treat.
Russel: Thanks for listening to the Pipeliners Podcast. We appreciate you taking the time, and to show that appreciation, we give away a customized Yeti tumbler to one listener every episode. This week, our winner is James Waymire with Energy Transfer. Congratulations, James. Your Yeti is on its way. To learn how you can win this signature prize, stick around till the end of the episode.
This week, Chris Carville with SCS Technologies is going to join us to talk about approaches to CO2 measurement. Chris, welcome to the Pipeliners Podcast.
Chris Carville: Thanks for having me, Russel.
Russel: If you would tell the listeners a little bit about yourself, your background, what you do, and how you got into CO2 measurement because that’s a fairly specific measurement.
Chris: As you said, I’m with SCS Technologies as a business development manager, and we specialize in measurement skids and vapor cover units and other packages in the energy space.
Before that, I was with Emerson, where I helped a lot with their SCADA and RTU development flow computers. Before that, I was with a major operator where I was a manager of measurement engineering. I’ve been working in this space for longer than I care to admit now.
Russel: You and me both, buddy. [laughs] What I’d like to do is dive in and talk about historically, how we’ve done CO2 measurement. I did a fair amount of that probably 10 or 15 years ago.
All the measurement that we came across was all worth its plates, and there was a lot of conversation about getting the right equation of state. Talk to us a little bit about what’s the historical approach to CO2 measurement been.
Chris: As you alluded to earlier, getting into this was fairly accidental, but looking at existing customers and the re-emergence or attention being paid to carbon dioxide with the tax credits and federal initiatives going out, it was real eye-opening to see what was going on. There were new customers there trying to figure out the best way to do things.
What was going on was classically orifice measurement with different equations of states, different assumptions on composition. As you probably well know, there’s no carbon dioxide standard like there’s for natural gas or crude. Everybody pretty much has their own secret sauce on how they handle carbon dioxide, measure it, and account it.
It’s been a real learning experience to see the different ways people are doing it. As with the invigoration of carbon dioxide sites, people are looking for what is the way we need to do it now and going forward.
Russel: I want to unpack a couple of things with you. First thing you talked about, and I use the word too, equation of state. For the listeners that aren’t aware, what is an equation of state and why is it important?
Chris: It’s been a while since high school chemistry. The equation of state is a equation or algorithm that will predict physical properties of a fluid based on the temperature, pressure, and composition.
Russel: Exactly. CO2 is rather a weird fluid, in that it exists, not just as a vapor and a gas as a solid, but it also exists in this supercritical state where it’s a hybrid of the three things and it has weird behaviors.
Chris: Yes. Technically, all fluids have a supercritical region. The issue with carbon dioxide is that supercritical region starts right where we like to put things in pipes.
Russel: That region is larger in CO2 than other fluids.
Chris: Right. The definition of a supercritical fluid is a fluid that is above the critical temperature and critical pressure of that fluid. For CO2, that’s, and this is not exact, about 1,100 PSI and 84 degrees, 85 degrees, so right in a sweet spot that anybody who’s been on a pipeline…
Russel: Where most of our gas transmission lives, is in that area. That means that all of the gas standards…I’ll put a little history in this. I should tell the listeners about this. My first job out of the military was as a CO2 applications engineer. 15 years or so later, we did a lot of work with CO2 pipelines and around CO2 for enhanced oil recovery.
It’s a difficult fluid to measure well and balance out because of what you’re talking about. The equation of state is basically the math you use to calculate all that. The problem, when you’re in that supercritical state, is a very small change in temperature or a very small change in pressure can make a very big change in the mass of the fluid you’re moving.
Chris: Exactly right, especially right at the critical point. The further you get away from the critical point, the more stable the fluid behaves. Pipelines being proposed today are talking about operating at 2,200-pound injection pressure, which is more than 1,000 pounds above the critical point. Carbon dioxide behaves fairly reasonably…
[crosstalk]
Russel: Reasonably well.
Chris: Similarly, ethylene also has a similar critical point in the sweet spot for pipelines and similar…
Russel: Very, very similar behaviors.
Chris: The old ethane standard…Was it API 11, I think, 321?
Russel: Sounds right.
Chris: Actually had a no-fly zone, where it said, “Between this pressure and this pressure and this temperature and this temperature…”
Russel: You can’t measure it.
Chris: “You’ll get a number, but who knows.”
Russel: Again, I want to unpack this a little bit. You talked about different people doing different things with CO2. What I found when I…Again it’s been a while. What I found is pretty much all the measurement was orifice.
You might find some other kinds of DP, like wedge or something like that, particularly close to the wellhead, if they’re worried about sand and such, but it was all DP measurement.
There was a pretty active conversation going on about what’s the right equation of state, there being two primary, one being NIST 14, which is a standard built specifically for EOR because it’s for hydrocarbon-rich CO2, like CO2 that’s 80 percent CO2 and the rest is hydrocarbons.
Then there’s NIST 23, which a lot of people preferred and would argue that it’s more accurate. You have to be a PhD geek that lives in a lab to be able to make that argument. NIST 23 dealt with not just CO2 but a number of other fluids that had unique behaviors. It was a more diverse equation of state, handled more things.
Chris: Talking with the guys at NIST, who, hopefully, we’ll see again next week at GPA — it’s always good to run into Eric and that team — they’re recommending moving forward to the NIST 23 in current equations and using REFPROP and tools that are publicly available. I guess you have to pay. You’ll have to license it, but it’s out there.
You can test the equations of state and everything. The one thing there though is these modern equations are CPU-intensive. When you get into your field automation, flow computers, it’s not a trivial add.
Russel: I can speak specifically to that because we built a CO2 flow computer using NIST 14. One of the things we found was, when we first started the algorithm up, we had to tell the algorithm how many components it was using. If not, you would run all…It was large. It was like 27 components that could be considered in NIST 14.
If you ran all 27, the cycle rate to run the math was just extremely long. You had to actually optimize the algorithm to be able to run it. That was actually one of the secret sauces about how we were able to run it and make it perform well and get good numbers versus what some other people had tried. We had a startup process that optimized the algorithm.
Consequently, we didn’t have to…There’s a lot of if logic in that algorithm. If it’s this, use this math. If it’s this other composition, use this math over here. Field automation chips don’t like logic. They like math.
Chris: It’s always interesting when you’re looking at controllers. Sometimes they’ll say, “23 components in this thing.” You go down to the fine print. They’re like, “You can select up to five.”
There’s another equation of state, the GERG 2008, also known as AGA 8, Part 2, which can handle carbon dioxide up to 100 percent purity. In my investigation testing, it appears to track very closely to NIST 23. We are seeing customers using that. That’s something that’s in flow computers today off the shelf, in its entirety. There are a few different options there.
Russel: We ought to unpack a little bit for the listeners. The reason that these equations of state are so important is I get a calculation from a DP. I get a flow coefficient. Then I have to apply that flow coefficient to an algorithm in order to determine a volume.
Chris: I call it the three points of orifice. When it comes to, really, any measurement, but especially when we’re talking carbon dioxide, I’ve got uncertainty in my composition. Is it from a GC? Are we just assuming a fixed rate? Are we going to sample it once a month and update it? Either way, real-time, it’s probably not exactly what you’ve configured or put in there.
I’ve got uncertainty from my equation of state that’s predicting the physical properties, that I’m now putting into a calculation for flow through a orifice with its own uncertainty. I’ve got these three pools. Each one have different options and different effects on your flow measurement. It’s just a lot to consider sometimes.
Russel: You can get to a pretty accurate volume pretty easily. You can manage those things pretty easily. Where it gets tough is when I take that volume and convert it to a mass.
Particularly because of what we’re talking about, we tend to operate around the critical point. Particularly in situations where you don’t have control of pressure and temperature, like where I’m injecting or I’m capturing, that gets a lot more complicated.
The uncertainties get so high because of the equation of state, particularly around the critical point, that my measurement can be off 10 or 20 percent for a very small change in one of those factors around the instruments or something like that
Chris: I ran a little REFPROP run, just out of curiosity. I took a tenth of a degree Fahrenheit at the critical pressure from zero to 150F and just ran the data. Then I took the difference between the density at each calculation. I did the same thing for pressure from zero to 3,000 pounds at the critical temperature.
In the vapor phase, there’s a little change, which you’d expect. As you approach the critical point — I’m pulling these numbers out of the deep memory banks here — I believe, at the critical point, the step…A tenth of a degree Fahrenheit is a pretty reasonable uncertainty in a transmitter. I believe it was nine percent change in density.
Russel: What happens is, if you have that in the temperature and then you say, “Well, I’ve got a half PSI in the pressure,” it’s actually a little more, depending on if you’re on the liquid or depending on where you are in the curve.
You can actually take that nine percent. You add to it another 9 to 12 percent. All of a sudden, I’m at a 20 percent error, just within the error of the transmitters that are extremely accurate.
Chris: That’s reason number 7,432 to not operate near the critical point. I’m actually working on the API work group working on a standard for carbon dioxide measurement now, API 6.X. They haven’t given us a…
Russel: It’s new enough it doesn’t have a proper name yet.
Chris: They’re not giving us numbers until we publish, these days. One of the early things we talked about was how do we figure out what the no-fly zone should be.
Russel: That’s a really interesting question. The other thing, if I’m going to try and do accurate measurement with an orifice and it’s around the critical point, then I actually need to do density measurement. There’s all kinds of complexities and costs and challenges of trying to do that…
[crosstalk]
Chris: Yes, but even there, you’re in such a dynamic system that, at some point, computers are grabbing data and making calculations. It’s not a 100-percent continuous operation. You’re sampling and calculating, even if it’s a million times a second. You’re in such a dynamic portion of the flow that, even with great instruments, you’re going to be chasing your tail around some mean.
Russel: I’m going to try and put this in non-geek speak. I don’t know if I’ll be successful.
When you’re looking at the processor and you’re actually running the math on the processor, it’s not just how quick you can sample and how many samples you can take, but am I sampling pressure, temperature, and, if I had live density, density all at the same instant of time and performing that calculation for that instant in time.
What you get into is the latency on the density is different than the latency on the temperature and the pressure, just because of the way the instruments work. That latency introduces a whole bunch of error.
This is a great tee-up for what I wanted to ask you next. We’re talking about, classically, how we’ve done measurement, which was we did it with orifice plates. We got equations of states that were appropriate for CO2. Then we tried to stay away from the critical point. That’s been the historical approach. What’s the approach going forward and why?
Chris: My personal, humble opinion, with all the new tax credits, people are looking at mass.
Russel: Because all the rules with the EPA are written in pounds of CO2.
Chris: Correct. Depending on what state you’re in, there are reporting requirements on volume, and we can’t totally neglect volume. If you’re concerned about mass, a mass meter makes a lot of sense.
I personally like going towards the Coriolis meters, especially at the high-pressure supercritical phase because I have direct mass-measured flow. The compositions and equations, the state, are unnecessary to calculate a mass in a Coriolis meter or to determine a mass.
Russel: Likewise, the equations to calculate volume from a mass are cleaner. They’re way more simplistic.
Chris: They’re cleaner. Conveniently, the Coriolis meter measures density, too. That’s your relationship between mass and volume. Now, I have mass, and density, and volume, regardless of composition, regardless of equation of state. Regardless may not be the best word there. Without needing the composition or equation of state, I’ll have an accurate measurement.
We may need the composition for reporting in quality-type assurances to claim credits or to report to the government agencies. Knowing that that meter is operating and producing a correct mass 24/7, without the need to feed it the information of composition or other things that may change, seems to be a simple, straightforward approach that makes a lot of sense to me.
Russel: Theoretically, I agree with you. Absolutely, it makes a lot of sense. If you’re going to be trading in mass, pounds of CO2, then it makes a lot of sense to measure in mass. The thing that comes up for me, and I’m certainly not current with Coriolis metering, and there’s been a lot of development going on with Coriolis. They’ve been improving that technology.
I’m curious as to, what are the operational realities of using Coriolis meters? Over the life of a Coriolis, what are the things you’re going to struggle with for a fluid like CO2?
Chris: There’s a few considerations. Coriolis meters, the big compensations or the considerations in your physical setup that come to mind are tube stiffness correction and speed of sound correction for carbon dioxide specifically. All fluids should have a tube stiffness correction implemented or at least evaluated to see if you need…
Russel: We should unpack for people that don’t know [laughs] what we’re talking about. What is a tube stiffness correction? I’ll talk first a little bit about the theory of operation of a Coriolis meter.
What goes on with a Coriolis meter is I flow a fluid through two tubes that are side by side, and as the fluid moves through those tubes that are in a U-shape, oversimplification, but in a U-shape, they move. They have a certain frequency, and I can determine what the mass of the fluid is by the frequency of the movement of those tubes.
Chris: Kind of.
Russel: Kind of. I’m trying to give a simple answer that listeners will understand. Please, get geeky on me, Chris. [laughs]
Chris: The Coriolis effect, which the meters are from, the best way I’ve seen it illustrated is holding a garden hose. You can hold the garden hose and swing it back and forth, and if you turn on the water, it starts to wiggle because of the force of the fluid going straight down, and then the hose not necessarily being straight down, depending on where it’s swung.
You put two tubes together, and the way they wiggle is very predictable in a way that you can watch the difference in peaks. This is hard to explain.
Russel: The garden hose illustration is good, because most people can visualize that. The bottom line is that the way that the shape of the hose is, is correlated to the mass of the fluid moving to the hose.
Chris: Ultimately, there’s sensors on both sides. Those sensors feedback, basically, a sine wave of the two moving further apart and closer together. You end up with a sine wave signal. At no flow, those sine waves are right on top of each other. They look like one line.
As you increase mass flow, they start to shift apart. You can see the peaks moving apart. The spacing there, as the peaks move apart, correlates to your mass flow.
Russel: Exactly. Then the other thing, again, to illustrate this is that the reason stube tiffness, tube stiffness — goodness gracious — is important is that…Again, you can visualize it with a garden hose example.
If I were to do that in a large garden hose versus a narrow garden hose or I were to do that in a fire hose versus a garden hose, the stiffness of that tube will change how those peaks behave.
Chris: Just like with your garden hose, if you turn on the water and the thing’s closed, it gets pretty stiff. If you don’t have the water on or you don’t have a valve on the end, you can squeeze it. It’s soft. The same thing happens in steel. It’s just not as easy to squeeze.
Russel: [laughs] Right.
Chris: Compensating for that is this tube stiffness…Now you’ve got me nervous about saying it.
Russel: [laughs] Sorry about that.
Chris: The tube stiffness compensation. It’s common across…This is a Coriolis…
Russel: It’s a common correction factor…
[crosstalk]
Chris: This is about the physics of Coriolis meters. There’s not, one, the “Brand A doesn’t have it, versus Brand B.” They all have this, to some layer or another. It does also vary with size. It’s a bigger compensation in bigger tubes versus smaller tubes.
That’s one part, especially when you’re operating at high pressures or, more importantly, where you’re operating at different pressures regularly. If you’re swinging from 1,500 to 2,200 pounds, the effect will change with that change in pressure. Constantly compensating for it can be really beneficial to your measurement accuracy.
Russel: What are some of the other considerations in terms of using a Coriolis meter?
Chris: Speed of sound. For, say, ethylene-carbon dioxide in the supercritical fluids, the speed of sound can have an effect on the calculations. As the speed of sound changes for these supercritical fluids, it can affect the output.
I talked to some folks at one specific manufacturer. They say, for carbon dioxide, they can see up to a four percent effect in measurement due to the speed of sound in carbon dioxide.
Russel: That makes sense because there is a correlation between speed of sound and the density of the fluid.
Chris: Correct. The good news there is individual manufacturers have built-in compensations and corrections for these fluids that will allow the meter to correct for the speed of sound changes and reduce your uncertainty throughout the range of measurement for carbon dioxide and ethylene and other…
[crosstalk]
Russel: I’m always amazed when you start talking about what we’re doing these days with measurement technologies, with ultrasonics and Coriolis and such, just the level of that technology and what we’re doing. Yet we’re able to do that in a very, very reliable way. That makes sense.
As we’re recording this, Chris and I are at the last day of the American School of Gas Measurement Technology in Houston. I had a conversation yesterday with a gentleman who is a purveyor of differential pressure metering. His opinion would be that differential pressure is the better way to measure CO2.
The point he was making — I’d like to hear your response to this — is that particularly on the capture side, where that CO2 can be dirty, I can have build-up or issues with scaling and such on the inside of the meter tube in the Coriolis. That can cause issues. What would be your response to that opinion?
Chris: Any measurement site is subject to impurities and special [indecipherable 27:50] that show up in the pipe. It would have to depend on what you were dealing with.
The good thing about what we do today is we can figure out what to expect in a pipeline through sampling analysis testing. We’ve got good friends downstairs at plenty of laboratories that would be more than happy to help us identify everything.
Russel: For me, when I think about this and having a lot of experience putting in orifice metering around CO2 and throughout the value chain, from capture to injection and transmission, the whole thing, what I would say is that you have to…
We’re talking about accuracy of the meter and quality of the measurement and the reliability and robustness. When I say robust, meaning it can measure accurately through a very big part of the phase curve and the critical phase.
That issue around the maintenance of the meters, I don’t know that we understand that fully yet. How much Coriolis meter is currently being done in CO2?
Chris: That’s one I can’t answer. I just don’t know.
Russel: Me neither. If I were to speculate, I’d say there’s probably a fair number of places where people are implementing it and testing it. In terms of the legacy measurement on the existing…I think we’ve got something like 5,000 miles of CO2 pipeline currently in the US.
Unless they’re changing that measurement, which I doubt they are, the lion’s share of all that legacy measurement, 95 percent or more, is all orifice.
Chris: This gets to the changing times. The legacy measurement, much of it is based on natural carbon dioxide sources and enhanced oil recovery and really no…I’m not aware of a lot of people worried about the over/short on their carbon dioxide for EOR measurement systems.
Russel: That’s actually an interesting conversation. They are, but it’s not about lost CO2. It’s about understanding what’s going on with their formation. The reservoir engineers want a good number.
Chris: Just as far as the midstream section of it, this new awareness, now that we’re talking multi-customer transportation systems and all these…All your incentives are based on what gets sequestered. Now I have to reasonably, potentially, allocate…
Russel: I’ve got to follow…
Chris: …a number back to inlet injectors. It really, to me, feels more like a Y-grade system, where I’ve got various compositions coming in and a value at the end that’s going to turn into purities.
Russel: I hadn’t even thought about that, Chris. It’s a really interesting point. The way these rules are written and the way these incentives, these credits, are written is you have to inject what you capture. If what you capture is greater than what you inject, there’s penalties associated with that. Is there not? Do you know?
Chris: Don’t make me lie about the penalties. From an incentive point, I know you don’t get paid unless it goes down the hole, in essence.
Russel: I don’t know. It’s a really interesting question. What it does allude to is, certainly, if the EPA is inspecting what you’re doing with your measurement and they’re looking at your balance, they’re going to be concerned about it. I have no knowledge at all what that looks like from a regulatory framework or any of that stuff, but it’s a really interesting question.
Now we’re operating a CO2 system much more like a gathering system or a transmission system. They’ve always done that. That’s not new, but the scrutiny that’s going to be placed on the measurement is going to be higher.
Chris: Even if the scrutiny is just at the wellhead, you still have customers that you have to have a fair and equitable redistribution of the sequestered numbers back to, based on their inputs and compositions. What are they going to accept? It gets commercial real quick when you start talking about these discussions.
Russel: It does. I don’t want to talk about that because I don’t know anything about it. [laughs] I won’t expose my ignorance. What I would say is I do know that most of the companies that are out trying to develop these CO2 capture, transmission, and sequester systems, for the new infrastructure, they’re all looking at Coriolis.
One of the things about Coriolis I would assert is it’s going to be a lot more forgiving through a range of measurement conditions. You’re going to have a broader range of measurement conditions, particularly at the receipt of wherever I’m capturing from.
Chris: The classic arguments for Coriolis meters, turndown, direct mass, all apply here. Even with something like carbon dioxide, you could get a three-to-one turndown just because the temperature changed.
Russel: Again, for the listeners that don’t know, turndown is…Typically, a meter will have accuracy within a certain flow range, like one to five, a volume of one to a volume of five. The larger the turndown, so instead of 1 to 5, 1 to 10 or 1 to 20…The turndown is I can get accurate measurement from 20 down to 1. That’s what we’re talking about here.
Particularly with an injector where they don’t have control — I say an injector, but a capture point — where I don’t necessarily have control because the process is driving how much CO2 is coming through, then that turndown becomes really important.
Chris: Any pipeline injection becomes that, even production and traditional measurement. Coriolis really shine there, with larger turndowns than orifice. From the operational standpoint there, back to pros and cons, fewer plate changes, more…
Russel: Less complexity in the operating of the measurement.
Chris: The end-all, be-all, if something happens to your GC, your measurement is still going to be accurate without the input of a real composition.
Russel: I guess what I would say is a takeaway from this conversation is that the future is probably Coriolis. There’s a lot of work going on to create standards and such for that kind of measurement.
Chris: Yeah, unless we come up with something better in the near future and newer.
Russel: Somebody somewhere is working on that, I’m sure.
Chris: I hope so. It’s exciting to see advancements, not only in existing technology but as new stuff comes to the market. The people that are bringing new stuff to market and trying out there, I really have a lot of respect for those guys that are doing it.
Russel: Me too. Me too. I’ve been doing this a long time and one of the things I know is, as you work a long career, and I’m sure this is true for you, is you touch a lot of different things, and at a point in your career, you have a really deep understanding of a particular issue and the problem and the technology around all that, and then five years later, you still have that recollection.
One of the things I’ve learned is that, even though I did CO2 and I did CO2 pretty deeply for a fairly long period of time at a couple of different points in my career, that really has very little bearing on my knowledge of what’s currently going on. I appreciate you coming by and sharing all this. It’s really interesting.
Chris: It’s always great to talk with you, Russel.
Russel: Thank you, man. I hope you enjoyed this week’s episode of the Pipeliners Podcast and our conversation with Chris. Just a reminder, before you go, you should register to win our customized Pipeliners Podcast Yeti tumbler. Simply visit pipelinepodcastnetwork.com/win and enter yourself in the drawing.
[background music]
Russel: If you have ideas, questions, or topics you’d be interested in, please let me know either on the Contact Us page at pipelinepodcastnetwork.com or reach out to me on LinkedIn. Thanks for listening. I’ll talk to you next week.
[music]