On this episode of the Oil & Gas Measurement Podcast, Dean Minehart of Emerson Midstream joins to discuss the complexities of natural gas liquids measurement.
The episode explores the differences between direct and inferred mass measurement, industry practices, and the challenges tied to sampling and accuracy. The discussion provides listeners with insight into how these methods impact contracts, operations, and overall measurement reliability.
Direct vs Indirect Mass Measurement of NGLs Show Notes, Links, and Insider Terms
- Dean Minehart is a Business Development Manager with Emerson. Connect with Dean on LinkedIn.
- Direct Mass Measurement — Measurement of fluid mass using a Coriolis meter that outputs pulses per unit of weight (e.g., pulses per pound). Defined in API Petroleum Measurement Standards.
- Inferred Mass Measurement — Mass flow calculation derived from a volumetric flow meter combined with an online density measurement, rather than directly measured by a Coriolis meter.
- Volumetric Measurement — Measuring liquid or gas flow by volume, often requiring additional density calculations to determine mass.
- Coriolis Meter — A flow meter that directly measures mass flow by detecting fluid inertia within vibrating tubes. Widely used in NGL service.
- Density Loop — A system that places a density meter either upstream or downstream of a volumetric meter to provide continuous density input for inferred mass measurement.
- Pycnometer — A precise vessel of known volume used to field-prove density measurements by weighing a pressurized NGL sample.
- Density Meter (Densitometer) — A device that measures fluid density, often used in inferred mass measurement systems and subject to field proving.
- Prover — A calibration device used to verify flow meter accuracy. In mass measurement, provers are equipped with density measurements to enable inferred mass proving.
- Mass Meter Factor — A calibration constant applied to mass meters (like Coriolis) during proving to ensure accuracy in custody transfer.
- Meter Proving — The process of verifying meter accuracy against a known standard volume or mass, critical for custody transfer.
- Online Chromatograph (GC) — An analyzer that continuously measures fluid composition by taking periodic (e.g., every 5–8 minutes) samples and feeding data to a flow computer.
- Flow Computer — A device that calculates quantities like flow rate, mass, and component volumes using meter signals and composition data.
- Custody Transfer — The point at which ownership of a hydrocarbon product changes hands, requiring precise, auditable measurement.
- Composite Sampling — Collecting proportional samples of fluid over a measurement period, stored in a vessel for later laboratory analysis.
- Shrinkage — Reduction in total measured volume when different-sized hydrocarbon molecules (e.g., ethane vs. pentane) combine, due to molecular packing effects.
- Component Barrels — The calculated volume of individual hydrocarbons (e.g., propane, butane) within an NGL stream, determined by mass measurement and composition analysis.
- API Petroleum Measurement Standards (API MPMS) — Industry standards published by the American Petroleum Institute governing measurement practices; Chapter 14, Section 7 defines direct and inferred mass measurement.
- Tariffs — Commercial agreements on pipelines that may specify measurement methods for transported hydrocarbons.
- Upstream / Midstream / Downstream — Segments of the oil and gas industry; upstream refers to exploration/production, midstream to transportation/storage, and downstream to refining/marketing.
- Produced Water — Water that comes to the surface along with oil and gas production, sometimes measured with specialized meters.
Direct vs Indirect Mass Measurement of NGLs Full Episode Transcript
Weldon Wright:
Welcome to episode 48 of the “Oil and Gas Measurement Podcast,” sponsored by EnerSys Corporation, provider of Muddy Boots field operations software, assisting oil and gas operators to implement accurate and repeatable measurement activities across their entire operation, while also simplifying data collection from the field.
Find out more about Muddy Boots at enersyscorp.com/software/muddyboots.
[background music]
Announcer: Welcome to the Oil & Gas Measurement Podcast, where measurement professionals, bubba geeks, and gurus share their knowledge, experience, and likely a tall tale or two on measurement topics for the oil and gas industry. And now your host, Weldon Wright.
Weldon:
Hello, I’m Weldon Wright with FpvPrime Measurement Consulting. I have with me today Dean Minehart, Business Development Manager at Emerson Midstream. We’re going to talk a little bit today about the differences between direct mass measurement and inferred mass measurement, primarily on natural gas liquids.
Dean, how are you today?
Dean Minehart: I’m doing just fine, Weldon. Thank you so much for having me.
Weldon: Tell us a little bit about yourself, Dean, how you got to where you are at Emerson, and what y’all do over there.
Dean:
It’s an interesting story, of course. I was raised in a place called Plato Center, Illinois. There, there is no oil and gas. We have more corn and soybeans kind of thing. After that, I attended DeVry University in Chicago, where I studied electronics technology.
When I graduated, there was a company that came to campus and actually did some recruiting, called Dresser Atlas. Dresser, at that time, was a wireline company. They recruited me to come to Houston and work in their research and development department.
I did that work. That’s way upstream, of course, being very close to the wellhead. Did that for about six years. What happened was we hit eight-dollar-a-barrel oil in the later 1980s, so I realized I wanted to migrate a little further downstream or [indecipherable] .
I had a wonderful opportunity then come around to go to work for a company called Solartron Transducers. Solartron was the market leader in online density measurement at that time. Our primary customer base is every midstream company that existed at that time. I made some really good relationships there. That led to how I got to where I am now.
In the meantime, I went off and chased some large automation projects, working for a couple of different companies, where we were bundling hundreds and sometimes thousands of field devices with automation.
In 2011, I had an opportunity to come to Emerson, where I am now in my current role as a business development manager. That was due to the fact that I had some experience working with these Solartron products that Emerson had acquired during the period of time when I was off doing other things. Good natural fit. I was fortunate to get the opportunity to come on with Emerson.
In my current role, what I do is I support our midstream customers, primarily working with Coriolis and density devices, but also a little bit of clamp-on ultrasonics and some mag meters in produced water and pressure and temperature devices are prevalent all over. That’s basically how I got to where I am and what I’m doing now.
Weldon: That’s a great path to get there. I don’t want to derail this podcast, but if you look back 20 years ago, would you have ever dreamed we would be spending the money we are today on water measurement?
Dean: [laughs]
Dean: No. Absolutely not. I understand the concerns. I agree that we need to improve measurement and be more aware of what we’re doing environmentally. I’m a proponent, but no, I never could have seen this coming.
Weldon:
It’s just crazy where it’s gone so fast. What we’re really here about though, Dean, is we’re going to visit today about direct mass measurement, again, of NGLs, liquids, as opposed to inferred mass measurement or volumetric measurement of those liquids. They both have their places. A lot of people have strong opinions on which is better.
Let’s launch into that part of the discussion. You want to start off by telling us a little bit…Let’s review for our users, what are the differences in these two technologies? Why does that difference exist?
Dean:
Coriolis meters are capable of doing direct mass measurement. Where we define these terms in the API Petroleum Measurement Standards is actually in Chapter 14, Section 7. That’s where these definitions exist. They say that direct mass measurement is when you have a Coriolis meter and its pulse output is configured to output pulses per pound. That’s direct mass measurement.
Then they also define inferred mass measurement. Inferred mass measurement is any time that you’re using a volumetric flow meter in conjunction with a discrete density loop to calculate mass flow online. That’s the primary difference. We’re either using a Coriolis meter, or we’re using some sort of volumetric meter in conjunction with a density meter to determine the mass flow rate.
Weldon:
As we talk about those two standards…Of course, API tells us we can do either one. API doesn’t give us a preference for one of the two, but I know it’s a pretty polarized discussion. It gets polarized because the devil is always in the details.
How do we get there? We’ll talk later on in the conversation. What we’re always doing with hydrocarbon measurement is we are measuring to what the contract says because there’s very few laws or real regulations around how we do measurement on a commercial basis. It’s really based upon contracts, agreements with companies, or maybe tariffs on the pipeline side.
Those documents will spell out how we’re supposed to do our measurement. The people writing those documents sometimes have some strong opinions.
As we talk about that volume and mass measurement, talk just a little bit more about what…You mentioned volumetric measurement with an online densitometer. Talk a little bit about how we put those two pieces together, if you would.
Dean:
With an inferred mass measurement system, what you’ll see is a density loop, which is either located upstream of a volumetric meter or downstream. Preference would be downstream because most of these installations on NGL service turn out to be turbine meters. Of course, turbine meters need some flow conditioning upstream or straight run at a bare minimum.
To get the density meter as close as possible to the same operating conditions that the volumetric meter is measuring at, typically these density loops are downstream. In order to implement this measurement, first off, we need to volumetrically prove the meter, just like any other meter and volume service, do it the same way, but we also have to prove the density meter.
In that density meter loop, there has to be connections for a pycnometer. That pycnometer is actually used to field-prove the density measurement. We’ve got two meter factors there that both have to be right.
Contrasting that to direct mass measurement, in the case of direct mass measurement, there’s only one meter factor. It’s a mass meter factor. During the measurement interval, with direct mass measurement, there’s less uncertainty because you’ve just got the meter proving that you’ve done, the meter factor, in mass meter factor. That’s it.
In the case of the inferred mass measurement system, during the entire measurement interval, it’s quite important that there’s a representative sample going through that density meter loop during the entire measurement interval while you’re measuring your mass during that period.
In my view, the contrast here is that there are more things that can go wrong during the measurement interval with an inferred mass measurement system. Not that I’m biased or anything, but obviously I have a preference for direct mass measurement, for that reason.
Weldon:
I think what you hit on there is my view on mass versus volumetric with a densitometer. When we go with that inferred mass measurement, there are so many other devices.
When I started in this industry and started working on the NGL skids for the first time, which would have been back when, maybe ’95-ish or something like that, there was no Coriolis meter being used wide-scale out there. They were around. They weren’t in wide-scale use.
There’s so many pieces to that puzzle. The first time, I thought I was a smart guy. Been to college. Got that engineering stuff in my back pocket. Been in the industry a few years already. I’ve seen a lot of stuff.
Then one day I watched them do a pick to prove the densitometer. I’m like going, “What in the world are we doing in this industry?” Done properly, it’s very precise. It can be repeatable, but the entire process of that…
For especially our younger folks out there that have never seen that because their company is all Coriolis measurement or possibly the folks on the gas side — we have a lot of gas-only users out there — when we do a pick, when we prove that online densitometer, we have a little sphere. We actually fill that sphere with pressurized NGL.
We go through a lengthy process to make sure there’s no bubbles in that. We get the temperature stabilized. We weigh that little vessel and then do our calculations from that. It’s a touchy thing to do. It takes a skilled guy to do it right, doesn’t it?
Dean: Yeah. Your definition of density is mass per unit volume. That sphere is a very accurately known volume. Applying pressure and temperature corrections to that volume and then literally weighing it, that’s how we come up with what the pycnometer density is actually indicating. It’s a very visual process.
Weldon: The first time I saw it done, the guy had the scale sitting on the toolbox on the back of his pickup. The pickup was idling. [laughs]
Dean: Not exactly the best workflow process.
Weldon:
Back to what you said though, five minutes ago, there’s much more complexity. That’s not to say we can’t go wrong with direct mass measurement, but there’s more pieces there. There’s more arguments to that also, more potential for discrepancies. I shouldn’t say, “Argument” or “Disagreement.”
The other thing we do is we have another device there. We have that densitometer device on there. We’re worried, did it work all month? We’re always going to have one, maybe two composite sampling vessels there.
We’ve also got a pump injecting the sample into a vessel. We let it sit there all week or, maybe worse, all month. Then we’re going to claim that we mixed it up perfectly, took a sample out of that, took it to a lab, had a lab analyze it.
Based upon the analysis the lab takes, we’re going to get a density for that and say, “Maybe I believe my online densitometer.” Of course, that whole story — we’ll talk about this some more later — the sampling and the analysis of your product, also falls into that same category.
Dean: For sure.
Weldon: How do you believe that densitometer was right all month long?
Dean:
That’s right. We didn’t maybe describe the fact that we’re measuring these natural gas mixtures by mass because the mixtures themselves are made up of a lot of different hydrocarbons, everything from ethane to C5-plus.
What happens is you can make a direct analogy to dealing with particulate. If I had one barrel of rocks and one barrel of marbles and I dumped both of those barrels into a two-barrel container, I would end up with a volume resulting something less than two barrels. The reason being that the smaller particulate is going to move itself and position itself around the crevices of the larger particulate.
You can imagine, if we’re talking about all of these hydrocarbons with different size molecules, ethane being the smallest and pentanes being the larger, depending on that composition and how it’s changing over time, we’re going to have very different results in terms of trying to predict what the volume might actually be.
This is not to mention the fact that we also have pressure and temperature, when we’re dealing with the hydrocarbons, changing flowing in the line. Trying to predict volume of these hydrocarbon mixes has proven to be extremely difficult because they, one, have shrinkage and two, some of the components, especially the ethane, are very compressible.
It’s a real challenge to measure by volume. The fact of the matter is — you were talking about contracts earlier — hydrocarbon contracts for the various components in the mixture, like propane, an example…Propane’s sold by volume. Somehow, we need to measure in mass and then get back to, what is the volume of each of the components in that mixture?
The sampling conversation that you were having is actually required in order for us to compute what the actual component barrels of the mixture is. I hope that that further elaborates on why the sampling is so important.
Weldon:
That’s something I think gets overlooked in our industry a lot, Dean, and how you’re doing that sampling. Our industry, for years, was resistant to the use of an online chromatograph in the measurement of NGLs.
The industry was resistant to having a device that, every five minutes or eight minutes, was getting a new sample and updating that directly to the flow computer. We were resistant to doing that.
We stuck with that concept of…We’re going to pump a sample into a big pressure vessel. We’re going to hope that…No. We’re going to believe, blindly, that that pressure vessel didn’t leak anything out during the course of the week or course of the month. Then we’re going to mix it up. Then we’re going to analyze what’s in that pressure vessel.
The truth of the matter is, if we’re talking about a pure liquid or pure gas and we leak a little bit, the analysis of what’s in the vessel is still the same. That doesn’t happen with NGLs. The seal that’s leaking just the tiniest amount, the big components are not going to go out that leak. It’s going to be the smaller components, that ethane.
Dean: We’re going to bias that measurement.
Weldon:
Any methane that was in the NGLs, that ethane, it’s going to leak out of there. It’s going to bias that, as you said. We’ll be richer, if you will, in the heavy hydrocarbons. We’ll get a higher density when we do the calculation. We’ll get a different GPM value for each of the components. It messes up our whole calculation.
Let’s switch this around a little bit. Talk to us a little bit about what it looks like when we’re doing measurement, strictly mass. We’ve got a Coriolis meter out there. We’re getting a pulse that is a pulse per pound or 100,000 pounds. What’s happening with our measurement? How do we get to the right answers doing that path?
Dean:
That’s direct mass measurement as API have defined it. The challenge there is it was the first time ever in the manual where we talked about mass proving. Prior to that, everything in chapter four that related to meter proving had to do with volumetric meter proving.
How do we get to mass measurement and a mass meter factor? What we have to do is we have to convert that accurately known volume at the prover from the prover water draw to mass. The way that that is done is that we actually fit the prover with an online density measurement at the prover.
Again, any time we have a density measurement that’s applied to custody transfer, that density meter has to be proven in the field, again, using a pycnometer in the case of natural gas liquids. One of the keys is actually getting a good density meter proving before we start making prover runs to do our inferred mass proving, is what it’s called, inferred mass proving.
From a workflow process, it’s really important that that density meter factor from one proof to the next actually reproduces. If that density meter factor isn’t reproducing, the mass meter factor that results isn’t going to reproduce either.
That’s an important thing that I stress any time that I’m talking about natural gas liquids and inferred mass meter proving. This process of proving the prover density measurement is quite critical.
Weldon: Even when we get, though, to direct mass measurement, that doesn’t relieve us of the requirement that we have a true representative sample, does it?
Dean:
No. That’s right. We need a flow-proportional composite sample in that sample chamber. You alluded earlier there are people in industry with strong opinions.
There are some folks that say that, “For safety reasons, I don’t want my people handling a sample, so I will place an online GC and have it feed the compositional information to a flow computer and calculate component barrels in real time.”
On the other hand, there are other people in industry that say, “I’ve read the standards. The standard doesn’t say that I can do that. It says, ‘Thou shall sample.'” Then there are some customers that’ll do both. I’ve seen that too.
Anyway, one way or the other, we need to have a sample of that flowing fluid during the measurement interval that is proportional to the composition that we’re measuring as we’re totalizing that mass.
At the end of the day, we need to calculate the component barrels based on that mass times the composition of each of the components to come up with the mass of each of the components, dividing that mass of that component mass by density at standard conditions, like I was talking about earlier, to actually calculate what the component barrels are from that process.
We measure by mass, but we sell by volume. It takes a number of steps to get all the way through the process that all have to be done correctly.
Weldon:
Absolutely. There’s a number of steps, but the steps you take between mass and inferred are geared to get you to the same end result. We do the steps in a different order. Just when you start looking at the data and start beating it up over time, it’s pretty easy to see that mass measurement is a simpler and more reliable way to get to that measurement, at least in my humble opinion.
Getting back to that component barrels to sell for, for the folks on the gas side that think that gas is complicated, on the liquid side, when we start talking about NGLs, when we start talking about volumes, there’s a couple of different volumes we talk about there. We talk about net. We talk about gross volumes. What are we getting to?
That shrinkage, that ability for those smaller molecules to hide in between the larger molecules, that can make a big difference on volume. We’re not talking something out at three or four decimal places, are we?
Dean: No. This is definitely one percent to three percent-type shrinkage levels. It’s a big deal. It’s not optimization, by any means.
Weldon:
If you get the wrong mixture, the wrong pressure, and hot temperatures on there, I’ve seen those differences five and six percent even, at times.
Understanding how to put those pieces back together and when we start with direct mass measurement and we have a true representative sample, then we have the pieces to get to that component volume with a step or two less than if we went the other direction.
If we measure by volume, we’re going to have to do those conversions to get from that mixed liquid down to the component basis. I lost where my train of thought was going. Talked myself out of something there. Regardless whether we’re doing inferred mass or direct mass measurement, we still rely on that analysis…
Dean: That’s right.
Weldon: being representative and correct.
Dean: One way or another, we need to have an accurate composition, whether it’s done online or whether we take a sample and send it to a lab, either way.
Weldon:
I said, before we got started, that some people feel very strongly about composite sampling of NGLs. Some people feel very strongly about online chromatograph sampling. I feel strongly about both. I really hate them. Both have room for problems. Historically, both have had a lot of problems.
I just know that I’ve seen too much data that tells us that if we inject a flow composite sample into a sample pot and mix it up and analyze it a week or a month later, when we do that as opposed to running an online chromatograph that’s feeding data on a continuous basis, you get slightly different numbers.
Is there anything else you’d like to mention before we go, or do you think we’ve landed this ship?
Dean:
I think we’ve done a pretty good job talking through how the process works. What I would say is, if careful attention is paid to all of the various steps in the process that we’ve outlined here, that pipeline balance can actually be very good.
It takes a lot of attention to detail. Nevertheless, just because it’s a hydrocarbon mixture doesn’t mean that it can’t be measured with a fairly low uncertainty.
Weldon: Fair enough. I’ll agree with you 100 percent on that. Attention to detail, attention to detail, attention to detail though.
Dean: For sure.
Weldon: Thanks a lot for being on, Dean. I hope this helps our listeners get a little better idea of some of the complexities and the pros and cons about the two. Thanks again, sir.
Dean:
Thank you for having me.
[background music]
Weldon:
I just realized that this may be our first natural gas liquids-focused episode. Maybe we gave some of our gas measurement-focused folks a glimpse into the other world.
If you enjoyed the podcast, please spread the word by telling your boss, your coworkers, and industry peers about our little podcast. We’ll have Dean’s contact information, along with a full transcript of this episode and a few definitions, in the show notes on our website, pipelinepodcastnetwork.com.
If you have comments or questions about this episode, suggestions for future topics, or if you’d like to offer yourself up to the podcast microphone as a guest, send me a message on LinkedIn, or shoot me an email at weldon.wright@fpvprime.com.