In episode 29 of the Oil and Gas Measurement Podcast, host Weldon Wright is joined by Andy Hartman, lab director at SPL, to discuss various aspects of hydrocarbon lab work, focusing on liquid analysis.
Andy shares insights from his 10 years of experience, detailing sample collection challenges, lab procedures, and the importance of accuracy in analyzing liquid samples. They delve into topics such as sample stratification, flash and shrink factors, gas chromatography, and the significance of standardized procedures in ensuring reliable results.
Throughout the conversation, they emphasize the critical role of meticulous sample collection and adherence to established protocols in maintaining data accuracy and integrity.
Hydrocarbon Lab – Behind the Scenes Show Notes, Links, and Insider Terms:
- Andy Hartman is the Lab Director at SPL. Connect with Andy on LinkedIn.
- SPL is a leading provider of compliance and testing services for Environmental, Energy, and other end markets. Through their ISO and NELAP certified labs, verifiable test methods, and nationally recognized scientists, SPL is dedicated to ensuring accurate and defensible data to its clients and communities.
- Sulfur Speciation – A wide variety of sulfur-based chemical compounds are found in produced crude oil and natural gas. These range from simple to complex molecules that are commonly grouped into “Species” that share similar traits. Some of which are useful, such as the mercaptans, used to odorize natural gas. Some are reactive and must be removed or neutralized to prevent corrosion and/or biological toxicity.
- Sulfur Speciation, or Sulfur Species Analysis, is the process of identifying and quantifying sulfur species with a hydrocarbon sample. Sulfur Speciation does not refer to a specific laboratory test or process; instead, it is a general term referencing to a wide array of ASTM, ISO, API, and GPA test standards.
- A Piston Cylinder is a specialized sample collection and transport container designed to maintain a hydrocarbon sample in a pressurized state throughout the collection and transport process. The cylinder is has valves at both end and a piston is free to travel inside the cylinder, separating the sample gas/liquid from an inert fill media. As sample is collected, the piston moves, displacing the fill media, allowing the sample to be maintained at the pipeline pressure.
- Heavy Ends refer to the larger hydrocarbon molecules (typically C5-pentanes and larger) that will condense and remain a liquid at normal atmospheric conditions. Also referred to as “natural gasoline” and “condensate”, these larger hydrocarbon molecules have higher monetary value than the light hydrocarbons.
- GC (Gas Chromatography) is an analytical technique used to separate the chemical components of a gas mixture and then qualify the individual components. GCs are frequently used in natural gas measurement to determine the quality and heating value of natural gas for process control and custody transfer purposes. Hydrocarbon samples in a liquid state (crude, condensate, NGLs) are analyzed in a gas chromatograph by vaporizing the sample at high temperatures as the sample is introduced by the sample valve. The heated chamber of the chromatograph is maintained at a temperature that assures the sample stays in gaseous phase as it is processed. Varius industry standards defined how the samples are collected, handled, and how the analytical process is conducted.
- GPA 2103 – Method for the Analysis of Natural Gas Condensate Mixtures Containing Nitrogen and Carbon Dioxide by Gas Chromatograph
- GPA 2177 – Analysis of Natural Gas Liquids by Gas Chromatography
Hydrocarbon Lab – Behind the Scenes Full Episode Transcript:
Weldon Wright: Welcome to “Episode 29” of the “Oil & Gas Measurement Podcast,” sponsored by GCI, the Gas Certification Institute. For more than 20 years, GCI has been providing measurement, fundamentals, training, and measurement standard operating procedures to the oil and gas industry.
Now, they proudly offer Muddy Boots Online, the field operations platform. Let GCI show you how Muddy Boots can streamline your field measurement operations.
Announcer: Welcome to the Oil & Gas Measurement Podcast, where measurement professionals, bubba geeks, and gurus share their knowledge, experience, and likely a tall tale or two on measurement topics for the oil and gas industry. Now, your host, Weldon Wright.
Weldon: Hello and welcome to episode 29 of the oil and gas measurement podcast. I’m here with Andy Hartman today, the lab director over SPL. Andy’s here to talk to us a little bit about the wide breadth of things that go on in the hydrocarbon lab, but we’re going to focus primarily on the liquid side of that.
Andy, thanks for being here. Tell us a little bit about yourself and what you do over there at SPL.
Andy Hartman: Hey Weldon, thanks for having me. It’s an honor to be here. I’m happy to share my perspective and the knowledge that I’ve gained over the 10 years I’ve been working here at SPL, at least from mainly a laboratory guy perspective.
As I just said, I’ve been with SPL for 10 years. I started with them basically right out of college. My degree is in microbiology, but I did a fair amount of research for my OCHEM professor, which helped get my foot in the door as a lab technician at SPL. I started there in February 2014, working for their lab in Pleasanton as a technician.
A year and a half later, I got lucky. They saw something in me that made them inquire if I wanted to help them open a lab up in Colorado. The company was expanding and I jumped at the opportunity to go to the mountains, and fell in love with the state.
Also it was a great opportunity career wise. It gave me the opportunity to learn a whole lot about what it means to be a lab manager at a petroleum lab.
I also got my hands dirty out in the field. I collected a lot of samples. I was training on how to collect a proper gas sample, a proper liquid sample. I got to see both sides of it which I think is perhaps somewhat unique. A lot of people get stuck doing one or the other.
I’ve gotten to see both. How collecting a sample in the field affects the lab analysis. I did that for three years out in Colorado, the lab was in Windsor, and it’s now in Greeley. I didn’t think I’d leave Colorado but opportunity came again. The company was growing some more and wanted my help out in Midland.
I moved down there to that operation, stayed in Midland for a year, saw some growth and helped them get that operation up and running, and then did the same thing in New Mexico. I’ve done three startups for SPL.
Weldon: You’ve got the new lab thing down pretty well then I assume.
Andy: I think the younger guy with the freedom to be able to move around like that and it seemed like a fun adventure to me at the time. Yeah, so I got to bounce around.
Weldon: I know SPL is a company that’s been around the industry quite a while. They’ve developed quite a good reputation. I’ve used SPL labs. I’ve used SPL consultants for audits over the years. They’ve built quite a reputation. They built that reputation around doing things well and understanding the industry.
What we’d like to talk about today, as I mentioned I know that y’all do a lot of stuff at SPL. Gas lab, liquids lab, I think y’all do some environmental stuff also. Today’s conversation, I’d like to focus around on the liquids side, more specifically crude and condensate analysis.
Talk to us a little bit about the testing that y’all routinely do. What’s the majority of y’all’s work along those lines? What are the problems with that? Most specifically, what we’re looking for here is how do we equip the guy in the field to do a better job getting you samples that y’all can analyze properly? What are y’all doing in the lab once you get those samples?
Andy: Sure. That’s a great question. Then that’s a lot to unpack.
You mentioned, what does it mean to take a good sample in the field and how does that affect us in the lab? An overall theme that I would broadcast if I was in the field and wanted some info from the lab, is that we want a single phase sample.
All of the basis of what we do in the lab, that’s the guiding principle, that’s the foundation, is that we assume that this sample and we have means to check it but our assumption is that a gas sample comes in, it’s a representative gas sample from the stream that it’s collected from.
A liquid sample is going to be 100 percent liquid. Liquid hydrocarbon, hopefully. Not a mix of water and hydrocarbon.
Weldon: Well…
Andy: That’s a big assumption, right? Of course, those separators out there in the field don’t work 100 percent perfectly, and there’s little things that can make the difference there when collecting that sample.
If you want to focus on liquids, let’s focus on liquids. The hardest thing about collecting a liquid sample probably is maintaining pressure and going slow enough when collecting that sample that you’re not allowing that sample to flash and turn two phase. Turn into a gas, form a gas pocket there. Does that make sense?
Weldon: Yeah, absolutely.
Andy: I’m sure that’s something that’s been taught perhaps to the sample collectors, but what we see on the lab when that happens or what’s going to trickle farther and farther down to cause, I would say, not inaccurate data necessarily of what’s coming out of the GC.
Whatever you put into that GC is going to come out, but something that’s going to trip up allocations or farther down the chain as this data gets used, and they look at it and go, “Now why is there either too much methane? Why is there a big gas pocket there that shouldn’t be there?”
Or the opposite. “Why is there none? Why was it allowed to seep out?” Going slow, allowing a liquid to slowly fill up a container, a piston cylinder, or a water displacement cylinder is key.
Weldon: I think one of the things that happens to us, Andy, is I know in the field we train, train, train, and we emphasize sample collection very heavily. We do that in classes where we’re teaching measurement to new technicians.
We’re reviewing practices, standard operating procedures are going to dictate that, our on the job training dictates it, but in reality, those guys don’t–guys and gals, sorry–they don’t normally see what’s going on inside of that cylinder.
We think we’re doing right, we know what that procedure is, but all too often, we’ve got eight more samples to collect today and it’s five minutes to quitting time. We already know we’re going to be there late. All too often we hurry a little bit. We take a little shortcut.
I think what we miss in the training that we do with folks in the field is we miss teaching them the why is it a problem. The why is it a problem if you don’t do it correctly. Hearing from you that you see problems, what percentage of the time?
If you took back a 30,000 foot level and you looked at all the light hydrocarbon samples y’all have come in in the course of a month, what percentage of those would you say likely weren’t collected perfectly?
Andy: It’s a great question. Under five percent. Under five percent. On a lab like this, we’re seeing thousands of samples a week, and so that number becomes somewhat significant. Usually, it’s something that we can nail down as if it came from the same guy, there’s something procedural missing here that we need to talk to him about.”
There’s also stuff out of control of the guy collecting it. How good is the equipment he’s using? The bottle itself needs maintenance. DOT recommends tearing apart a piston cylinder every year. Does that always happen? No . Even if it does, there’s a lot of mechanical pieces there that can fail.
Getting blow across that piston, those o rings wearing out, getting tired. Either liquid getting in on the pressurized, on the pre charge side, or vice versa, some of that back pressure gas getting into the liquid sample. Those are obviously going to cause issues.
Valves themselves, a lot of times, everything’s done right, and when it shows up here in the lab, one of those dang valves got kicked open and a plug wasn’t tightened down. Or maybe it even was tightened down, but little things [laughs] like that, of course, will affect that sample.
Weldon: I’ve been on several different sides of this. I have been beating on technicians because I didn’t think they sampled properly. I’ve been beating on the labs who were charged with doing the maintenance on the cylinders for us.
I’ve been from the, I want a piston cylinder tore down every use, clean the new o-rings in it, to realizing that every time we tear a cylinder down and rebuild it, there’s a chance we don’t quite get the rebuild right, so maybe we shouldn’t do it. I’ve been on all pieces of that.
You said earlier maybe five percent or a little less than five percent of samples that y’all can look at and say, “Hey, we see there’s a problem.” It doesn’t sound like a lot, but that’s, five percent, 1 out of 20. Something like that. When we’re talking about the dollars that we’re involved in in the hydrocarbon industry, that can add up in a big hurry, you know?
Andy: Oh, God, yes.
Weldon: Let’s talk a little bit about the type of analysis, the type of tests y’all are doing there in the lab. What’s involved in those and what does that look like in the lab itself? Because most of the folks listening to this podcast will never have seen what goes on behind the magic doors where they drop the samples off.
Andy: Let’s peel back the curtain that is the lab, right? Number one, I’ll give a quick plug. We love giving lab tours. If anybody’s interested, reach out on our website.
That is sometimes the best thing that can happen, is to get a team of guys from the field or people in the back office that are looking at this data and reviewing it, get them in there so we can show them what’s going on in the lab.
The first thing, the most common thing we do with these liquids, is give a compositional analysis. Most people have seen these reports. It breaks down each of the components in a liquid sample. Nitrogen, methane, CO2, ethane, propane, butanes, pentanes, hexanes. Breaks down the mole percent, the weight percent, the liquid volume percent.
The way we do that is with a gas chromatograph. A full half of our lab is dedicated to that piece of equipment. We call it the GC lab. All of these samples, they need to be logged in so we can keep track of it. We log them into our limb system, and then they, more often than not, enter that GC lab.
On liquids, we need to initially determine what it is. There’s two main different tests that we’re going to initially divide them into. Is this a heavy condensate or crude oil that’s going get a GPA 2103 analysis, or is this something lighter, like a Y grade or an NGL, that is going to get GPA 2177?
The main difference with those is one of them is designed for a crude. That can have super heavy hydrocarbons out to C80 and larger, that if we allowed to tear up our instrument, it would in a hurry.
More than that, those heavy hydrocarbons aren’t going to make it through the GC properly, and it’s going to overstate your light ends because all those heavy ends aren’t going to come out. They’re not going to reach the finish line.
I’m talking about some stuff before I explained it, but does that make sense? We need to first divide them into two camps there. One of the things we love to show guys, and usually people are surprised about, because number one, it’s not a whole lot of sample…
Let’s say a company asks you to go collect a liquid sample. You look at that bottle that we give you, and you’re going, “Man, all I’m collecting is 400ml of liquid, and they want me to do this once a month.
This one little 400ml sample is going to be representative of this well side for the entire month.” It gets even smaller than that, guys, because all we’re injecting into this GC, if you looked at your pinky fingernail and the little white part of the top of it, basically the volume of that nail is what gets injected onto the GC. That’s all we’re analyzing. It’s a tiny amount, half a microliter.
When a bottle opens–let’s backtrack a little bit–whenever that sample bottle…Let’s say you do a perfect job and you have a completely representative sample in that bottle from the field. Right when you set it in the back of your truck and starts to sit there, that liquid is going to start stratifying.
And we see it. We see it all the time. Literally, you can see lines in that liquid start to form of the different components. The heavier stuff’s going to start to fall out towards the bottom of that bottle, and the lighter’s going to be at the top.
If your valve opens there in the back of your truck and some of it leaks out and you see it and go, “Oh, shit, I’ll close it,” and you twist that valve shut, you’ve already changed the composition of that sample.
Because let’s say it’s stratified–let’s talk about it in layman’s terms–and it’s stratified, and right in front of that valve is now mostly butanes. It’s not a perfect mixture of what you collected in it, but now you’ve altered that composition. Does that make sense?
Weldon: Yeah, absolutely.
Andy: We have to take special care to, before we inject that tiny amount of liquid in our GC, we have to apply extra back pressure so as we open it, it has enough pressure to maintain itself in a liquid state on the backside of that piston, but also shake it.
You can hear those balls inside of those cylinders shake if you were to mix it around in your hand. Those are all key pieces of the process here that would dramatically affect results if they get overlooked here in the lab.
Weldon: Thanks. That’s some great information. That’s some great knowledge for folks in the field. I do want to loop back to something you said earlier. I wrote it down and flagged this. Take just a moment to explain why we use a gas chromatograph to analyze liquid samples.
Andy: [laughs]
Weldon: I know that’s going to cause flags for folks, right?
Andy: Another great question. It’s a question that you’d think I’ve spent a whole lot of time thinking about, but it’s quick. It’s reliable. It’s something that’s been done in the industry for many decades. There’s been developments in GC technology through the years and, and we’re moving towards smaller and quicker means of doing it, right. Micro GCs. It’s the best technology we have right now to analyze hydrocarbons.
Weldon: The answer I was shopping for there, I think that’s why are we using a chromatograph? Which still is the quickest, most cost effective means in many cases. What I was shopping about was that answer about all of our chromatographs really process gas. They don’t process liquids.
You have to flash, you have to vaporize that liquid sample, but vaporize it very carefully. We want to make sure we’ve captured the right volume of liquid and then completely vaporize that liquid within the chromatograph.
Andy: You’re absolutely right. As the name implies, even though we’re injecting a liquid, it is immediately vaporized as it enters and travels through the GC.
Weldon: What else besides running stuff through the gas chromatograph do y’all do?
Andy: We have over 200 different analyses that we offer on liquid hydrocarbons. Some of the routine ones that we see a lot look at sulfur analysis. That’s a great one. We have different means of quantifying sulfur and its different components speciated. A method that’ll speciate all of them are captains.
Weldon: That’s a big word.
Andy: All the different sulfur components, right? UOP 163 is a tried and true on crude oil for breaking out H2s and quantifying that. 6667 on some of the lighter liquids, that’s a total sulfur.
We do total sulfur on crudes by x Ray D4294 and trace metals, so 5708, looking at trace metals and liquid. Density is a common one, D86 distillation. There’s a lot that we can do with liquid hydrocarbons. When you first reached out to me, we wanted to mention gasses too, and it’s not as easy to play around with.
As soon as it leaves that bottle, we can’t do much with it, but with the liquid, we can do different tests on a pressurized liquid sample and then after we dispense it to atmospheric conditions, there’s a lot of different methods we can do with that as well.
Weldon: I know for the folks in the back office, our balance analysts, our measurement analysts handling the data after we get it from the field, as we go into the settlement accounting and the allocations flash factor become such a big thing.
That flashback, a lot of dollars rolls around based upon that every month for every company out there. Talk to us a little about how you get that number. Where does that magic percentage come from?
Andy: I love talking about the flash factor because you can visualize it. I love that it’s one of those tests that we do both physically and theoretically with software. It’s simulating what’s going on out there in the field. In simplest terms, as somebody starts collecting oil coming out of the ground, an operator has drilled a new well, they install a separator. The simplest setup is to set a tank battery out there and start collecting that liquid.
As we’ve already discussed there’s the same hydrocarbons in the gas as here is the liquid. Depending on the temperature and pressure that that hydrocarbon is at, is going to determine if it’s in a gas or liquid phase. As it reaches that tank battery and starts to cool and depressurize, it’s going to turn into a gas.
Your meter, maybe you have a meter counting volumes of liquid coming out of that well, and then your truck driver comes up to haul off and empty the tank battery and you’ve only got 80 percent of what your meter said, that’s your shrink factor.
That’s what we do in the lab. We simulate that. Collecting a pressurized oil sample there off the separator upstream of the dump valve, we bring it into the lab and simulate that exact process.
Let’s say we have a burette that we started with 200ml of liquid. We dispense it into that burette at atmosphere conditions, and it goes up to 160. That’s your shrink factor, 0.8. 80 percent of it’s state of liquid. Then what goes hand in hand with it is a flash factor, which quantifies how much gas came off. We can do that here in the lab.
Weldon: Not only how much gas came off, but what did that gas look like, is also important.
Andy: Sure.
Weldon: A lot of pieces to that puzzle, right?
Andy: Absolutely. It’s amazing to me that when we compare it, because we run, depending on the company, they decide if they want the physical way of doing it or maybe they want us to run it through simulation software. It’s amazing how close that they come in, which is a testament both to both methods.
Weldon: Right. That’s what with GPA midstream or just the Gas Processers Association until 10 years back. That was their focus for many years, was around the analytical, around the procedures. I think a lot of folks out there don’t realize how those procedures are developed.
It’s not a case where we just said, here’s a theoretical process we do in the lab. Once the smart folks got through with that part of it and decided, “Here’s a procedure,” with GPA, AGI, API, regardless of which group you’re looking at, they’re going to take the procedures out there and they’re going to do large scale testing to determine, what’s the acceptable accuracy? How much difference?
When we talk about these tests, it’s not just we developed a test for putting amount of liquid in a piece of lab where, and raises the temperature and letting it vapor it off and right down the line. The procedures are very, very detailed.
Not only that, GPA would go out and select a group of labs that wanted to participate. They would do round robin testing. They would have the labs repeat the same test with their equipment multiple times, different labs, put those comparisons together to come up with, “Here’s the accuracy, here’s what we expect.”
That’s both on the physical test procedures themselves, the analytical, the calculations, like 2172. A lot goes into all that stuff. A recurring theme of mine is that one of the best ways to learn more about our industry is to get involved in our standard organizations, whether that’s GPA Midstream, API, AGA.
Get involved with those groups. You don’t have to be an expert to be involved in them, but I guarantee you, once you get involved, you’re going to learn something.
Andy: Absolutely. I had the opportunity to go to my first ASTM conference in New Orleans a couple of weeks ago. It’s amazing that it could stay that organized with so much going on, but the coolest thing I saw was actual work being done.
They want input from folks like me at the lab. They want input from folks receiving the data, and these things are constantly being reviewed and updated and it’s based on studies like you’re talking about.
From a laboratory perspective, there’s perhaps no greater means of us to verify that our results are accurate than being involved in a round robin. We readily volunteer to be part of any and all.
Weldon: Great. We may be getting towards a good place to stop there. Is there anything else you’ve got on your list you wanted to talk about or anything else you want to say?
Andy: One of the things that we talked about was, and shrink and flash has a field method, and you and I had talked about grindouts and the difference between perhaps the field method and the lab method and gave it a little thought to it.
I think the overall difference is we’re in a controlled environment here. It allows us to take our time to control just the parameters in the lab, temperature wise, of heating these samples up, and the [indecipherable 28:55] used to mix it. I’m talking about S&Ws in particular right now, but the methods are written to be a field test or a lab. One way or the other.
There’s more stringent things that we’re adhering to here, but is one better than the other? Is one more accurate than the other? I think there’s an argument to be made.
Weldon: Probably the key thing there though is that when we’re doing a grindout or a shakeout, as I’ve heard it called also. It took me a while to understand why they call it shakeout till I saw the first one of those misbalanced centrifuge just shaking an entire truck.
The key thing to remember there is, as you mentioned, many of these procedures are designed by GPA or API to be a field procedure. But just like the sample collection itself, the procedure has to be followed, you have to be systematic and repeatable in how you do that procedure to get an accurate and repeatable result, right?
Andy: Yeah.
Weldon: All right, I want to thank you again for being on the podcast, Andy. I think this is some great information. I hope it provides some insight to our folks in the field. Thanks for doing it and we’ll have you back on again sometime and we’ll talk about the liquid part of this world. How does that sound?
Andy: I appreciate it, Weldon. It’s been my pleasure.
Weldon: Thank you, sir. Have a great day.
Andy: You too.
Weldon: I want to thank each of you for listening, and I hope you found this podcast both entertaining and informative. If you did, please share our podcast with your coworkers, your boss, and others in the industry. We will have a full transcript of this episode and Andy’s contact information in the show notes on our website, PipelinePodcastNetwork.com. Your reviews help folks find their podcast by making us more relevant for the search engines. Please take a couple of minutes to do a review on iTunes, Google, or wherever you get your podcast fixes from. If not a review, just go in and click and give us a thumbs up or five stars.
As always, if you have comments, questions about this episode, suggestions for future topics, or if you’re brave enough to offer yourself up to the podcast microphone as a guest, then send me a message in LinkedIn or shoot me an email at weldon.wright@fpvprime.com.
Transcription by CastingWords