In this episode of the Oil & Gas Measurement Podcast, Weldon Wright is joined by Chris Harlow of Emerson Rosemount to discuss production-level measurement in upstream oil and gas operations. The conversation provides a high-level look at common level measurement technologies used on well pads, separators, and production tanks, along with the operational challenges operators face in real-world conditions. Listeners will gain perspective on how evolving measurement technologies and better use of data can support safer, more reliable production measurement.
Production Level Measurement Show Notes, Links, and Insider Terms
- Chris Harlow is the Manager of Level Technologies at Rosemount, Inc. Connect with Chris on LinkedIn.
- Oil-Water Interface is the boundary between layers of oil and water that forms as the lighter hydrocarbon products float on any water present in the tank. Water and hydrocarbons are immiscible liquids and will generally separate out, given enough time
- Emulsion forms in a separator due to inadequate retention time of the immiscible liquids (oil and water). The physical properties of the emulsion (density, viscosity, conductivity) will differ from either pure liquid, creating difficulties most level measurement technologies.
- Sight Glass / Manometer: A transparent window or tube used to visually observe the liquid level in a tank.
- Hydrostatic: Use submersible transmitters (pressure gauges) that measure the pressure exerted by the fluid column above them. They are known for being durable, cost-effective, and simple to install, making them a popular choice for many applications, but require known and consistent density
- Capacitance: Uses a probe inserted into the tank and the tank wall as the two plates of a capacitor. The transmitter measures the variance in the capacitance to calculate the tank level.
- Radar (Microwave): These sensors use microwaves and work well in extreme temperatures and pressures and are unaffected by changes in the oil’s density or viscosity.
- Non-contact radar: Sends microwave pulses from above the tank, which reflect off the liquid surface.
- Guided wave radar (GWR): Transmits microwave pulses down a probe or cable within the tank. It is precise, reliable, and can measure liquid-liquid interfaces, making it useful for measuring oil-water separation.
- Ultrasonic: These sensors are a non-contact method that uses sound waves to measure the distance to the liquid surface. They are ideal for measuring corrosive or dirty fluids because the sensor does not need to be in contact with the process medium.
- Tank Stick or Float Stick: One or more floats traveling on a stick or rod inserted into the tank, with a sensor to determine the position of the float. Magneto-strictive sensors are a typical implementation that use a magnetic float and a low-energy pulse that travels through a probe. They are suitable for interface measurements and are unaffected by foam or emulsions, leading to high accuracy and low maintenance.
- Nucleonic (Gamma): This technology uses a source that emits gamma radiation. It is often used in separation and refining processes to measure levels through thick-walled vessels or in situations where other technologies would fail. The cost of this technology limits it’s use.
Production Level Measurement Full Episode Transcript
Weldon Wright:
Welcome to episode 51 of the “Oil & Gas Measurement Podcast,” sponsored by EnerSys Corporation, the provider of Muddy Boots field operations software, assisting oil and gas operators to implement accurate and repeatable measurement activities across their entire operation, while also simplifying data collection from the field.
Find out more about Muddy Boots at enersyscorp.com/software/muddyboots.
[background music]
Announcer: Welcome to the Oil & Gas Measurement Podcast, where measurement professionals, bubba geeks, and gurus share their knowledge, experience, and likely a tall tale or two on measurement topics for the oil and gas industry. Now your host, Weldon Wright.
Weldon:
Hello. I’m your host, Weldon Wright of FpvPrime Measurement Consulting, and today, we have Chris Harlow, the Business Development Manager of Level Technologies at Rosemount, with us today. We’re going to talk about tank level measurement.
Before we get started on what we’re going to speak and how we’re going to constrain our discussion for today, welcome, Chris. Tell us a little bit about yourself and what you do there at Rosemount.
Chris Harlow:
Thanks for the invite. Like you said, I am the Level business development manager for Rosemount. Basically, it’s a fancy way of saying I’m responsible for the Level business for process level, whether that be upstream oil and gas production tanks, separators, or any other industries such as chemical refining. Even mining, things like that.
My job is to really help my salespeople get the information across to engineers, project managers, even technical support with the technicians on the ground that are actually touching the devices all the time. When I was originally hired in this role, I was considered a specialist. The wonderful thing about a specialist is you’re supposed to be the all-encompassing know-all, which can be a double-edged sword.
Where we found ourselves becoming is we became more of that back-end technical person helping everything in the field, and it really didn’t allow us to try to help grow the business by being on the front-end sales part of it. Emerson Rosemount has ultimately transitioned us into that business development manager role.
I’ve been in this role for right at six years, six and a half years. Before that, I was actually Rosemount sales out in West Texas, out in the Permian Basin. I sold all pressure, temperature, level, and DP flow technologies out in the southeastern New Mexico, western Permian Basin. Odessa, Pecos, Carlsbad, right in that whole Delaware Basin area.
Then before that, I was actually…
Weldon: Spent a lot of time out there myself.
Chris: Yes, many, many, many hours. Actually, before that, I was an eighth grade science teacher for about 10 years.
Weldon: Oh, wow. That’s quite a change.
Chris: It is, very much so.
Weldon: Wow.
Chris: I got tired of the political BS. I got tired of being told I had to do things certain ways. I had to focus on low-level learners, blah, blah, blah, blah, blah. I had a church member who was asking if I’d ever be interested in sales, and that’s how I got my foot in the door here.
Weldon: We have a daughter that teaches elementary school here in Texas. I know that she wouldn’t say political BS, but she might echo some of those things, or a little nicer.
Chris: Right.
Weldon:
I understand what you’re saying there.
Back on the level of technologies part. First of all, for our listeners, when we start talking about level measurement, I’m going to get the air quotes there. We don’t record the video here, luckily, because I have a face made for radio, I think is the saying.
When we start talking about level measurement, there’s several things we can talk about. In the oil and gas world, that usually rounds up into two different camps.
First of which is the custom, they transfer tank gauging — the technologies, the standards, and everything that goes into accurately determining the level of product inside of storage tanks or transfer tanks. That’s a technology that is very well-bracketed by standards, by known calculations. API speaks extensively about that.
Then, the other side, as I like to say, of measurement is what we do in the production world. What do we do on the well pad? What do we do with our production equipment itself?
Maybe even up to our midstream companies where they have their gathering facilities, which may be separate facilities than the production facilities, but located at an individual pad or an individual well site.
What we’re going to constrain today’s discussion about is that upstream piece. What do we do there? Level measurement, level instrumentation can still cover a fairly wide realm there. Talk to us, Chris, about what do we see with level measurement at the upstream side?
Chris:
When it comes to upstream, there’s many different types of measurement. I guess your tried and true measurement that’s been around forever is going to be your hydrostatic pressure-based measurement.
Are you wanting me to go into all the technologies on it, or do you just want me to give you a nice general overview?
Weldon: We can attack it any way you want to, Chris.
Chris: Got you.
Weldon: Talk to us in brief about what each of those technologies are, and then we can loop back around if they make good competition.
Chris:
There we go. We have a pressure-based hydrostatic, pressure-based level measurement. Basically, you have a product, whether it’s oil or water, that’s pressing on a sensor down at the bottom of the tank.
That sensor turns into either an analog signal or an electrical signal that tells you, “Hey, here’s how much pressure I have.” Then, that pressure helps determine the level of your product.
If my mind remembers correctly, 28 inches of water is one pound of measurement. If you’re able to take that ratio right there, then you can tell how much level is in your tank based off of pressure.
One of the small issues with that is it is based on density. If your density changes, then your pressure is changing. If you have a mixture of product in your tank, that level could actually be off because you have it configured or calibrated for a certain density. That’s your basic level measurement that a lot of people in the past have used.
Stepping up from that, and this gets into where my world is, we start getting into radar-based technology. There’s two types of different radars out there. There’s a non-contacting radar.
Basically, what that means is nothing is touching the process. Nothing is touching the product. We’re sending a microwave down, and we’re measuring the free space above the product.
When you have a microwave or a radar-based technology, you’re basically measuring distance down, and then that distance is subtracted from tank height, and you can get a very accurate measurement.
With non-contacting radar, depending on which radar you’re using, we can get down to two millimeters, maybe one millimeter of accuracy, which, if you think that compared to a tank gauging world, tank gauging is half a millimeter accuracy, so much higher accurate measurement in the tank gauging world.
The other type of radar that we have is a Guided Wave Radar. That is basically a microwave that is going down a guide or a probe, and that probe is inserted into the process.
The nice thing about a Guided Wave Radar technology is you can actually get two measurements. If you have a production tank or a separator where you have water and oil in there, you can get a fairly accurate measurement because the probe is actually going through the process.
There are some other technologies that can be used, such as point level. Point level, we also call tuning forks. We have some of our competitors out there that are also using Floats, but still, it’s a point level.
It’s going to tell you what’s happening at that particular point in your product. It’s either usually it’s going to be an on or an off. I’m either wet or I’m dry. The switch is either activated or not activated. It’s not a great technology for trying to determine what is in that area, but more of something is here.
A lot of customers tend to use those as high-highs, low-lows, high alarms, low alarms to know if I’m full or if I’m empty so I don’t either cavitate a pump or overflow my tank.
Weldon: Very reliable, but at the same time somewhat limited use also, right?
Chris: Yes.
Weldon: Your level of indications can vary a little bit. You get buildup on the floats or those sort of things.
Chris: Correct.
Weldon: The technology has been around a long time.
Chris:
Yes, it has. It’s tried and true. Like I said, float technology, if you think about your fuel in your car, how do you know how much gas you have in there? You’ve got a float that’s giving you a signal.
Then there’s other technologies such as…I call them tank sticks. It’s a float technology. It’s on a stick, two floats floating in your tank that are going up and down a rod inside your vessel. That float gives you a signal as to where it is on that product. You get a level. I believe that technology you can do level and interface as well.
There’s capacitance, which Emerson doesn’t do capacitance. I know some of our competitors do. There’s some ultrasonic and then sight glasses. If you really wanted to get fancy, you could go nuclear.
Weldon: Nope. I don’t think we have that much money on the pad.
Chris:
Exactly. Who wants to spend 50, 60 thousand dollars for one device?
There’s a multitude of technologies out there. It really is a matter of understanding what your application calls for and constraints in the level measurement that you’re going to have with how it’s going to be mounted.
Weldon:
Yeah. Probably as we look back, like everything, our technologies are changing rapidly. They’re changing even within the level measurement world, even though many folks think of the level measurement as the low-tech part of what they do.
There are also measurement techs in the oil and gas world that will never deal with any level measurement. There are pipeline measurement technicians, maybe they get a high float or something on a condensate or a separator tank downstream.
When we start looking at the guys that are in the production world and in the midstream/gathering world, level measurement is a key part of what many of those guys do, and yet it gets a backseat, if you will. Right, Chris?
Chris: Yeah.
Weldon:
When I started in this industry, we had just moved past the simple point measure, the simple floats. We weren’t doing the tuning fork technology back then. We were into those probe in the tank with one or two floats on it. Maybe that probe was inside of a well to still things. That technology was headache prone. It really was.
Not only was it headache prone, it required some maintenance. It required some cleaning, just like the capacitance sensors do.
It also involved not only working from the top of the tank, but if you were going to remove those probes from a tank of any size, are you going to do that by trying to haul them out by hand? Most cases not. You’re going to need a cherry picker, a boom truck, or something like that to remove many of those sensors.
We’ve come a long way since that, right? I know that the problems we tried to fix back when I first got in the industry are still some of the ones we have now, but we have different technologies attacking them.
Chris: Right. Absolutely. Yeah. Imagine trying to pull that capacitance, that metal rod or whatever it is, if it’s a long metal rod, out, like you said, from the top. Think about those windy days. Think about if they’re all coated up, how nasty you get. It’s a lot of different technologies now that can helps with all of that.
Weldon:
Not only that, there were safety issues related to that, not just from the wind. We get into parts of southeast New Mexico where there’s high H2S and their oil there and their condensates. That can be some safety issues. We’ve moved ways past that.
What I’d like to get you to visit with a little bit is when you talk to your typical customer today, what solutions are they looking for? What problems do they have? What are the typical solutions that we work around to get reliable and, let’s face it, low-maintenance cost technologies?
Chris:
One of the number one issues or concerns that I hear from customers about is emulsion. We don’t necessarily hear emulsion in production tanks as much per se. We do definitely in SWDs or high-producing sites. We do hear about it a lot in separators.
The customers want some accurate measurements so they can accurately separate their oil and their water.
If you don’t have an accurate measurement, then whenever you have your oil dump, you’re taking water with it. When you’re dumping your water, you’re taking oil with it, which those customers that are doing water hauling love because they’re getting free oil if it’s not properly measured, it’s not properly separated.
The emulsion issue is the biggest issue that I hear about or the biggest concern on a production pad. Honestly, it’s one of the hardest issues.
You have a producer that comes in and drills a well and they spend $5 million on it or whatever. They want to open that well wide up and they want to blow and go so they can get all their money back as quickly as possible to send to their investors. How do you get good measurement when you are full open blowing and going and sometimes with an undersized vessel?
Weldon: Well, it’s easy. If you design the facility for those flow rates, right?
Chris: Correct.
Weldon:
We have an emulsion because we’re not stilling the liquid adequately.
Let’s face it, that’s the thing we fight, have fought, and will continue to fight on the production pad. We have never gotten past that mentality that we should do our production measurement cheaply.
At the same time. Management, and operations specifically, keeps beating up on measurement to get better and better measurement in those conditions for no money. Most of the time when we talk about separators, the first flag that goes up in my mind is how undersized is it? Because if it’s not an old well, it’s undersized to some extent, right?
Chris: Right. Yeah, those initial production numbers come back really, really high, but the vessel that they’re putting on site is not designed for initial production. It’s designed for six months down the road or nine months down the road when production is tapered off. I understand it. It’s just a matter of how can we help with those issues and mitigate it for the customer.
Weldon: What would you typically recommend to a customer in that situation? If they’ve got a bad installation, if they’re undersized, what’s your here’s-the-best-we-can-do answer, typically?
Chris:
Well, the first thing I would try to say is choke back your flow, and then I’d get laughed at and ran out. If you’re wanting to produce the way you are and you’re wanting something that’s fairly accurate, my go-to, my top-of-the-line device that I always talk about is the guided wave radar.
First off, you get two levels with it, so your overall level is going to be pretty accurate. The problem is trying to catch that emulsion and that interface measurement. Some of our competitors have some dual technology out there, where it’s a two-in-one, and all we have is guided wave, but if it’s set up properly, it works pretty well.
Weldon: We’re not trying to do custody transfer level measurement there. We’re doing process control at this point in time, so I think that that age-old, hey, you have to work with what you have — is what we’ll be told from a measurement standpoint — many times it’s an education thing, isn’t it?
Chris:
I think it is. As long as customers, engineers, technicians, people that are on the site or are going to be touching the site, as long as they understand how the technology works and some of the limitations of the technology, it does go a long way. Even though there are limitations, there are ways that you can set up and ways that you can collect data to know something is happening in the process.
It’s not only having the right technology, but it’s also pulling in the right data. We’re in a world right now — they call it what, the IoT, the Internet of All Things — where data is king. If you have a device that can pull the data and you can do something with it, then you’re much further along than where you were. It’s nice to have technology that can do that.
Weldon:
I’ll agree. When you look at Guided Wave, particularly in a separator application, what falls into the manufacturer’s expectation for the type of maintenance and recalibration or routine calibrations that you would expect?
What is expected of the tech in the field when you have Guided Wave and separator applications? You just put it in, install it, and pray, or what happens after that?
Chris: [laughs]
Chris:
One of the nice things about Guided Wave, of course, it depends on who you talk to. It depends on how it’s installed. One of the nice things about Guided Wave is, first off, there’s no moving parts. It’s not like a pressure device, or we talked float device.
We’re not going to have to calibrate anything because it’s just a microwave signal. It’s a microwave generator pulse, which means there’s little to no maintenance. The problem we get is there’s iron sulfide, there’s paraffin. You could potentially have H2S that could eat away stainless steel.
There could be some issues with the probe itself from things like that. Usually, the maximum amount of maintenance that needs to happen with a Guided Wave is you might have to go in and clean off the probe.
If it’s set up properly, if it’s commissioned right with the correct configurations, the first measurement you get that’s correct should always stay a correct measurement. There’s no drift. There’s no maintenance.
If you are in an area where you know you’re going to have iron sulfide buildup or you’re going to have paraffin issues, or you know there could be high H2S areas, then you can actually get a PTFE-coated probe, which can help with some of that, make the probe slicker, try to keep the H2S from getting in there.
We have some competitors that have PFA-coated. As long as you can get a coated probe, that helps mitigate a lot of that issue.
Weldon: Again, into back talking about that original design of the site, right?
Chris: Correct.
Weldon: Knowing what they’re going to be receiving, do they expect a lot of paraffin from this production site? Do they expect H2S? All of those things we should be able to identify upfront in our engineering group should be ordering the right thing from you.
Chris:
Should be, but sometimes that doesn’t happen. Sometimes we start getting calls from customers saying, “Hey, we’re having this issue, blah, blah, blah.” I’m like, “Are you tracking any signals?” The great thing about guided wave is not only do you get a level, but you get data back. You get signal strength returns.
If you’re having an issue where you know you’re getting some buildup, and at some point you lose your measurement or your measurement’s stuck because you got stuff flowing out of your tank or whatever, and you go out and you start troubleshooting, you pull your probe out and you’re like, “Oh man, this thing’s gunked up. Let’s clean it, put it back in.”
” Hey, Mr. Chris, is there any way we can have some knowledge to know when this is going to happen?” “Yes. Yeah, you can start monitoring signal strengths.”
Or, if your device happens to have advanced diagnostics where you can get a number saying, hey, we’re seeing more noise build up, you might want to go check your probe. You can do that. Again, it’s all based off of the signal returns and what your device tells you.
Weldon: Technology is out there. The data is out there for us. Do we want to take the upfront work to get that data and have a diagnostic tool, or do we want to complain when it stops working? Those are kind of the questions, right?
Chris: Correct.
Weldon:
Honestly, look at what we have today with ultrasonic meters some years back or Coriolis meters we have on site right now. Those are incredibly intelligent systems with a lot of diagnostic capability.
Yet, I wouldn’t throw a percentage out there because it’d be a swag, but there’s not a high percentage of those type devices, the high-profile devices, that we bring that kind of diagnostic data back in or log it. We like to run out there with our diagnostics and plug in once a month or when it quits working.
The tools are there for us with guided wave if we’ll capture that information, or at least record it occasionally so we know what the device can do when it’s operating properly, right?
Chris:
Right, yeah. When I talk with customers and I present, I always talk about, OK, so your primary variable, bring that in as level. Your secondary variable, bring that in as interface. It really depends, are you trying to control your separator off a level or interface? They may swap those. They may go interface first.
Then I always talk about bring your tertiary variable as signal strength and bring your quaternary variable as interface signal strength. Because one of the other issues that I hear is not necessarily interface emulsion issues. It’s my radar keeps spiking.
OK, well, we don’t have an onboard historian. In order for us to understand how it’s spiking or what it’s spiking to, we have to actually try to connect to the device and hopefully record while we’re connected and catch it going on.
I try to talk to the customers, if you’re trending signal strengths and you say, “Hey, I had a spike last night at 10:33 PM. What do I do? What adjustments do I make?” Then I can go back and say, “Hey, go look at your trend and tell me what your signal strength was.”
Knowing that signal strength, that can give us more information on how to make some changes, whether we’re changing threshold settings, so if it does spike, it doesn’t catch it, so on and so forth. A lot of the customers are, I could say, maxed on the data that they’re bringing in and they don’t want to bring in more information over their SCADA.
I’m not exactly sure. A lot of customers aren’t bringing that in. I call those poor man diagnostics, and I talk about them for a reason, because it gives you more information, just like on your Micro Motion, your Drive Gain and — what is it — density?
Weldon: This is one of my pet peeves. I can get on a soapbox with it real quick. I’m going to try not, or at least keep it down.
Chris: [laughs]
Chris: We’ve driven for more accuracy. We’re driving toward we want less maintenance cost. We want smarter devices. We want more intelligent devices. Yet, so many places in our industry are stuck on, let’s face it, early to mid-1900s bandwidth on the data they can bring back to those systems, right?
Chris: Correct.
Weldon:
I chastised customers before over the fact you’ve bought all this equipment, you made all this other investment, and, yet, look where you’re on bandwidth. You can’t touch any of that information because you don’t have the bandwidth to go get it. Or, some ancient computer system between the field and your data lake can’t pass the data.
Again, this is kind of a let’s take a holistic approach like so many other things in measurement. Let’s look at what we’re trying to accomplish and make sure all those pieces along the way support it, right?
Chris: Right.
Weldon: Because data storage space, memory is cheap. Memory is cheap these days. The power of these devices increased many fold. What device are you choosing in the field that limits you is my question?
Chris: Right.
Weldon: Guided Wave radar in our separators. Let’s step away from the separator and start looking a little bit further downstream at our production tanks, our crude, our water tanks, maybe condensate tanks if this is a midstream gatherer. Talk about the challenges your customers face there. How do you all help them address it?
Chris:
Again, emulsion is a challenge. Of course, I know we’re stepping away from separators, but if you have a poorly performing separator, then you start having oil, water, mixture in your production tanks. That’s a compounding issue downstream.
One thing we’re actually seeing more and more of in the production tanks is you’re seeing H2S issues. Now customers are being limited with being able to go up on a tank and either do a tank strap or anything like that. That starts becoming a huge safety concern.
On your production tanks, you can use Guided Wave, you can use non-contacting. It really just depends on how much information you’re wanting. If you know you have great separation and you want to go non-contacting, go for it. If you don’t and you want to go Guided Wave, I think Guided Wave is a great thing for that.
Again, the nice thing about Guided Wave or not, it could be a nice thing, it’s just a probe that goes into the tank. If you want to use Guided Wave on a 16-foot tank, on a 20-foot tank, if you want to use it on one of your tall vertical tanks at an SWD, and you want to use it on your separator, you don’t have to buy five different lengths of Guided Wave.
You can just buy a Guided Wave 30-foot-long and you can cut that probe. It’s really cut to fit for your devices. Now you still get that great measurement on your production tank.
With the H2S potential and with Guided Wave, if you wanted, you could do 18.2 API custody transfer. If you’ve got a smaller facility where you don’t want to spend 30, 40, 50 thousand dollars to put a LACS skid, you could actually possibly use Guided Wave radar because it has an eighth of an inch accuracy on the manufacturer specs on it.
Again, that’s a long way to go around. One of the biggest issues we see is H2S. Customers having to go up on tanks, takes away your tank strap, Guided Wave radar could be used in place of that, as long as you’re confident with the measurement.
Weldon:
I think that that whole package of H2S, the safety aspects of H2S, that’s something we face with every technology out there, other than maybe standing back at 100-foot with our thermal camera and saying, “OK, that level’s about halfway up that tank.” Other than that, you’ve got to get the data into the tank, access to the tank. Safety always is an issue.
To me, we’ve been at this a long time. We know how to deal with the hazards in the production site or tank farms or wherever it might be. We know how to deal with those. We have the equipment. We have the processes in place for dealing with them. They take time. They take equipment.
The real goal that we’re facing is not how do we find a technology that lets us never make a penetration and look into the tank once it’s installed. We really are looking at a technology that reduces how often we do that, right?
Chris: Right. Correct.
Weldon:
Reduces how often we have to access it. Do we need to do routine calibrations or verifications, I should say? Is fouling such a big problem we need to be cleaning once a week?
Those things give us more frequent exposures as opposed to a technology that says, well, we can install this and at the very least we can reduce, possibly eliminate the times you need to access that probe after install.
What do you see on the worst case and the best case of that? I know that there’s Guided Wave radar out there that the probes are never seen once it’s installed. How frequently is that as opposed to the ones that we need to tinker with every now and then, clean every now and then?
Chris: I can’t really honestly answer that because I don’t hear customers telling me, “Hey, I’m having to go clean my probe all the time.”
Weldon: Which is good.
Chris:
I know it’s happening. I think the customers that have those issues, they just periodically do it because it’s just what they’ve done. I know that we’ve got thousands and thousands of radars out across the Permian Basin that once they’ve installed it, they’ve never really had to do much with. I think it just depends on what particular area you’re in and what’s going on.
I’ve heard customers tell me, “Hey, we haven’t checked on this radar in a long time. We realized something was wrong and we’ve got to pull the radar out, and there’s only half a probe there” in an H2S area.
Weldon: [laughs]
Weldon:
Apparently, it wasn’t enough of an issue at the time that they were worried about it. Yeah, it depends on the customer.
The question that I get a lot of times is, how much buildup can this probe get before the measurement goes wonky?
Again, that’s not something I can actually answer, because I’ve seen some customers, they get a little bit of slime, or whatever slime that they have from the production that causes that radar to drift. Then I’ve seen pictures where there’s a three-eighths of an inch, five-eighths of an inch of paraffin and iron sulfide built around it, that it’s measuring perfect. It’s interesting.
Weldon: That’s one of the things that’s always — I wouldn’t use the word fascinated — perplexed me, I guess, about guided wave, is I’ve seen cases where I looked at that and go, “That can’t be interfering with the measurement.” I’ve seen probes that I went, “How can it be measuring?”
Chris:
It’s interesting. I can’t give you an answer for that. All I can do is say, “Hey, let’s go back and let’s watch signal strengths,” because if we start getting buildup at some point, that buildup’s going to take energy away.
If you’re measuring signal strength return on your signals, and, again, it’s trending, if you’re seeing it over time degrading, then you know something’s going on.
Weldon: That buildup issue, isn’t that typically in our tanks? It’s not in our separators.
Chris: Yeah. We see it in the tanks, the slow-moving stuff.
Weldon:
That undersized separator on that brand-new well, he is not going to have a fouling problem. They’re stirring up things in that tank enough that…
[crosstalk]
Chris: Correct. You’re going to see it in the production tanks. Again, that’s where we see most of that buildup problem, is in the tanks. Even H2S issues, if something starts eating away that probe, we see it in a production tank.
Weldon:
We didn’t discuss this beforehand, so I don’t mean to put you on the spot here. I’ve talked with customers that were very mixed between capacitance and guided wave radar. I guess, at one point in time, if we had that type of probe, it was capacitance, probably.
Do you have any thoughts or any feelings about the reliability and how frequently you clean capacitance versus guided wave? I think I know the answer here.
Chris: [laughs]
Chris:
To be fully transparent with you and all the fans that we have listening and all the subscribers, I don’t know anything about capacitance. Our company does not really do capacitance.
We have a small capacitance probe we use as a solids switch, but as far as level measurement capacitance, I don’t really know about it per se, other than just the small amount of research that I’ve done.
It is my understanding that with capacitance, there is supposed to be a calibration done periodically, but I don’t know, and so if there is a calibration that needs to be done and there is buildup happening, then to me, that would throw off the measurement.
Again, I’m just speaking from the hip because I don’t really know that technology. I would assume if your guided wave radar is having to be cleaned, if you have a capacitance in that same situation, you’re going to have to clean it as well. I would assume it’s going to be close to the same amount of cleaning frequency. Again, I can’t speak to any certainty. I’m just shooting from the hip.
Weldon:
What little experience I have from both installed on similar products is that generally the capacitive seems to be more susceptible to the crud effect, especially paraffin for some reason. I’m not sure why.
Any other thoughts, Chris, that we have? I think you’ve given us some really good insight on Guided Wave and how that’s a great solution to a lot of our problems. Anything else you want to talk about before we break up here?
Chris:
Also, one thing to think about on Guided Wave, to me, it’s a great product, but in your production tank, if you’ve got a tall nozzle, or if you’ve got limited space to mount something and you’ve got a tall nozzle that say is a two-inch diameter, Guided Wave Radar might not be the best solution for that application because we do have that probe that hangs down.
That small two-inch nozzle can cause a lot of attenuation of the noise. It can bounce around and have a lot of spiking. If you have that type of mounting system, but you don’t necessarily need to interface, non-contacting would be perfect because we’re just measuring overall level.
To me, that’s one of the limiting things with Guided Wave in a production tank, is you just got to be careful how it’s going to be mounted.
Weldon:
Great. Well, if there’s nothing else, Chris, I certainly appreciate having you on. I hope our listeners get a good takeaway from this. Again, thanks for being here.
[background music]
Chris: Absolutely. Thank you for the opportunity.
Weldon:
Thanks for listening, and I hope you’ve enjoyed our podcast. I hope we’ve given you a little something to think about. As usual, we’ll have Chris’s contact information, along with a full transcript of this episode, in the show notes on our website, pipelinepodcastnetwork.com.
If you have any comments or questions about this episode, if you have suggestions for future topics, or if you’d like to offer yourself up to the podcast microphone as a guest, then shoot me a message on LinkedIn, or send me an email at weldon.wright@fpvprime.com. Until next time, have a great one and be safe out there.