Weldon Wright hosts Chuck Woods from Southern Petroleum Labs to discuss the intricacies of liquid proving and witnessing, focusing on the auditing and witnessing of liquid meters. The episode delves into the roles and responsibilities of a witness in the proving process, the importance of checklists, and the nuances of documenting and auditing meter proving reports.
Liquids Proving and Witnessing Show Notes, Links, and Insider Terms
- Chuck Woods is the VP of Special Projects at Southern Petroleum Labs. Connect with Chuck on LinkedIn.
- Southern Petroleum Laboratories, (SPL) is committed to meeting the needs of the Environmental and Energy sectors through their expansive network of laboratories and service centers. SPL is a leading provider of compliance and testing services for Environmental, Energy, and other end markets. By providing best-in-class laboratory, metrology, and data management services, as well as access to data in real-time, their customers are able to efficiently track and optimize their operations. Volumetrics, leader in fiscal loss mitigation of tradable energy products, was acquired by SPL in September 2023.
- Witnesses are third-party overseers who should carry a high-volume of knowledge over which they are witnessing. They should be overly-thorough focused field experts.
- NIST (National Institute of Standards and Technology) is a physical sciences laboratory and a non-regulatory agency of the United States Department of Commerce. Its mission is to promote innovation and industrial competitiveness.
- Meter Prover is a device that verifies and/or calibrates the readings of a custody transfer meter. There are numerous designs for meter provers that include Master Meters, Volume Displacement Provers (also called Ball Provers) and Volumetric Proving Tanks.
- Control Charts are graphs that plot the process data in time-ordered sequence. Control charts are used to track the performance of a custody transfer meter (or the prover itself) over time. An excessive change from previous performance data for a meter or prover indicates that an unacceptable condition exist, that must be corrected before proceeding.
Liquids Proving and Witnessing Full Episode Transcript
Weldon Wright: Welcome to episode 35 of the “Oil & Gas Measurement Podcast,” sponsored by GCI, the Gas Certification Institute. For more than 20 years, GCI has been providing measurement fundamentals training, and measurement standard operating procedures to the oil and gas industry.
GCI’s instructor led gas measurement and liquid measurement training classes coupled with comprehensive measurement standard operating procedures, provide valuable tools for both the back office and the personnel in the field.
[background music]
Announcer: Welcome to the Oil & Gas Measurement Podcast, where measurement professionals, bubba geeks and gurus share their knowledge, experience, and likely a tall tale or two on measurement topics for the oil and gas industry. Now your host, Weldon Wright.
Weldon: Hello, I’m your host, Weldon Wright with FPV Prime Measurement Consulting. I’m here today with Chuck Woods of Southern Petroleum Labs. He is the VP of Special Projects. He’s here to discuss with us witnessing, and the auditing of liquid meters.
Chuck, tell us a little bit about yourself and what goes on at SPL and what you do there. What exactly does a VP of special projects do?
Chuck Woods: Yeah, so by background, I’m a chemical engineer. I had my master’s in chemical engineering. Was in the process of getting my PhD in chemical engineering, when I met a very entrepreneurial guy.
Through a series of unfortunate or fortunate events, depending on how you look at it, wound up working as within the meter proving service industry for a company called Volumetrics. Did that for about 10 years, progressing from meter proving up to managing all of our liquid training, data management, and things of that nature.
Volumetrics was acquired back in September of last year by SPL. Here I’m at SPO as the VP of Special Projects, which really is a strange way of saying I’m also over liquid compliance in training for the metrology groups within the energy sector of SPL.
Weldon: Do you want to take a moment to tell us a few things that SPL does? Some of us are very familiar with Southern Petroleum Labs, some of us not so much. What’s the breadth of what SPL does?
Chuck: That’s growing by the minute. It’s a pretty wide swath all centered around primarily service. Serving Petroleum started as mostly a lab and analysis company. Has grown. Added field services and things of that nature along the way.
Right now, it’s two broad sectors, energy sectors and environmental. Within those two sectors you have your labs, your classic field services, and data management within those separate sectors. I sit in that energy section over the metrology group and liquid compliance within that group.
It’s a pretty broad category. We service anywhere from the northern border to Canada, all the way down to the Gulf Coast. Practically shore to shore at this point.
Weldon: What we brought you here today for is when we talk about liquid meters, operating on liquid meters, the liquid measurement, very often, when a tech gets sent out to witness the proving of their meter, we bring a third party in, or we’re the other party in a transaction, and we want to witness and make sure that the other party is doing it right.
What witnesses think they’re supposed to be doing when they get there, sometimes varies a whole lot. I know gas. When it comes to gas testing, calibrations, witnessing, auditing, that’s my forte. Not so much on liquids.
I would be a terrible witness for proving liquid meters, because what I teach on the gas side is if you’re going to be there to witness, you need to know as much or more as the person you’re witnessing, and you should be able to do that yourselves. That’s not me. Chuck, talk to us a little bit about when a witness is on site for the proving of a meter, what do they need to be doing? What’s their role in that job?
Chuck: It’s a complicated thing. A lot of witnesses get into their head that they’re just there to follow the prover around and maybe occasionally kick a LACT on, turn a LACT on, turn it off. That is important. Being able to operate the equipment and make sure that we have the capabilities to do our job is one aspect of it.
Liquid proving is not quite the same as gas. Typically, you can calibrate a gas meter without flow. There’s a lot of different ways to do that. With liquid proving, you have to have flow to the meter. There is a critical component of it, which is to be able to operate the equipment. The prover doesn’t always have that capability. That’s where the witness comes in.
A lot of times, witnesses feel like that is really their only responsibility. They take the classic definition of witness as somebody that’s literally seeing something happen. They take it literally. “I was there. I saw it happen.” Really, it’s more complex than that. You really have to understand what the test is that we’re trying to achieve and what that looks like to be able to do it properly.
There are other components to it besides just testing the meter itself. You’re testing that whole system. You’re there to verify that temperature gauges are working properly, pressure gauges are working properly. It’s more involved.
I would say the biggest advice that I would give is make sure that you’ve got a checklist. Any good witness really needs a checklist to know what are the items that I need to pay attention to, what are the things that I need to see that are happening, especially if you’re new to the task.
Weldon: I know [inaudible 7:21] on the oil and gas side. We’re going through. We should be making sure, as a witness, that the testing equipment has a current certification. Again, we’re not doing flow. When we start talking about a prover, that’s a whole different level of what’s going on there.
We need to see the documentation on the prover. We need to know it’s being operated right. That can be a pretty complex piece, I’m sure.
Chuck: There’s a lot of equipment there, for sure, depending on what kind of liquid proving you’re doing. If you’re just proving an oil meter, it may just be a prover itself. That prover, as you alluded to, has a certification. It has to be traceable to NIST. That’s the assurance that you have that that meter is being tested against something that is accurate as it possibly can be.
There are also ancillary devices though. There’s temperature probes that we use to test temperature averaging devices, whether they’re a temperature transmitter or whatever that is in a LACT. We test that against a certified temperature probe. We test pressure gauges against certified pressure gauges.
There’s a lot of paperwork there, potentially, for a witness to check, which is why I said I really would strongly advise to have a checklist there. Everybody looks for the water draw of a prover. That’s the certification for a prover. That’s the one thing that everybody asks for.
All these other devices, nobody really generally asks for. A particular technician may or may not have those devices on hand. We should have those. You should have those as a record. If you’ve got that as a checklist, you can always follow back up on those. At the end of the day, if I don’t have that paperwork, you’re just taking somebody’s word for it.
Weldon: That checklist is very, very sound advice there, Chuck. I’m pretty well-versed in liquids from the back office standpoint, pretty darn well on how do we spec a LACT, what’s our equipment need to look like, but not from that actual proving standpoint.
I know what I see from the office side. We get to doing an audit on a liquid or liquid and gas both maybe in the E&P world. When we get that information in, so, so many times, I see a test report for a proving. There’s nothing but the volumetric. Depending on what kind of liquids, maybe we’ve got a pick, if we were doing a purity product or something or a Y-grade pipeline.
These reports will not have a word on it that we did anything to look at the other equipment on the site. Did we look at pressures? Did we look at temperatures? It always leaves me wondering, “Did they not even look at that stuff?”
You call up a tech in the field. “Oh, yeah. It was all right.” Where’s your documentation? That’s part of that checklist also. Not only do you need to know it was done. You need to document that it was done and done correctly and the equipment used to do the verification…
[crosstalk]
Chuck: There’s a number of softwares out there to be able to prove a meter. Some of them are better than others. To your point with what you’re mentioning, most of them are lacking in this regard. They focus a lot on collecting the data to get an accurate meter proving, but they don’t really give you a place to say, “Did I verify that the block-and-bleed was actually seating?”
It’s a hugely important point. If your block-and-bleed leaks, then essentially the test needs to end there. There’s no point in testing the meter if I can’t verify that all the oil or product that goes through the meter is also going through the prover.
It doesn’t give you necessarily a place to say, like we were talking about before, “Did I verify that the temperature probes are reading correctly? Did I verify that the pressure gauges are reading correctly?”
SPL has taken…With my help, we’ve added some stuff to our traditional proving reports that do capture that in more of an auditable way. It is an important point. A lot of times, it just either is left off entirely. Or it gets relegated to notes. Or it gets relegated to an email or something that’s harder to follow up on.
We’ve tried to make a concerted effort to put that into a field that you can audit. It goes along with that proving report long-term so that you can see, specifically, “This is the temperature probe that I used. This is where the paperwork is for it.”
Weldon: Part of what I think happens is we get very focused on the fact that the only thing we’re out there to achieve during a prove, our entire work product, is just do we have a good meter factor or not. Do we have a good meter factor, or we were not repeatable enough? That seems to be the end of the discussion.
If we haven’t looked at temperature…Depending on the product, pressure may be involved. Pressure is a very small part for our liquids. If we go out and get a prove and later we decide, “Wait a minute. The temperature probe is not right,” we need to recalibrate. We need to replace an RTD or whatever happens on that. We make a change for temperature.
Now, wait a minute. We have just forced our meter factor to make up for what that bad temperature was doing at the temperature we tested at. Our prove is no longer good at any other temperature. Understanding that is important to the folks in the field.
Chuck: It’s a big point. I give these talks a lot. It continually surprises me how unimportant people view things like temperature, for example. Even if people do understand that temperature is important, they don’t necessarily understand how important it is.
A temperature probe that’s off by one degree is about 6/10,000ths, which isn’t a ton, but you’d be surprised at how many times we find temperature probes that are off by three or four degrees. They’re not calibrated properly. They could be off by three or four degrees.
Or they’re pulling from the wrong place. They’re pulling from an address that is not the device that is actually doing the measurement. It’s not all that hard to be off by a half a percent just because you haven’t checked that temperature device, whereas we put a lot of focus and emphasis on the meter.
You also brought up a good point too, which is that we tend to focus…A lot of witnesses feel that their job there is to make sure that the meter passes. If every meter passed, I wouldn’t have a job. Provers are more like insurance in that way. We only really pay out when we find something wrong.
If a meter fails, that’s where proving has its value because then we can correct that value. We can correct that meter, that accuracy. We can get to what the true value is of that product. If every meter was a meter factor of a one, there’d be no reason to prove the meter anyway.
It’s an important distinction to make to focus on the right things. That’s what witnessing really is about, is making sure that we’re focusing on the right things.
Weldon: Great, Chuck. Thank you for that insight. Having that list, making sure we’re focused on the right place, making sure we’re attentive in documenting, all those things are great points. Take us a little bit past the point of that fuel technician that’s out there to witness the proving being done on his meter or the other party’s meter.
Talk to us a little bit about, if you were engaged to audit or do an audit on liquid meters, what are you looking for? What does that process, in general, look like? What are the details there?
Chuck: Validation after the fact is one place where, as I said, there’s a lot of different proving softwares out there. None of them do this very well. This is always relegated to the back office of whatever customer we’re dealing with.
Obviously, there are some things that are pretty easy to check off, like certifications and things like that, to make sure that things are in compliance. I always point to the BLM. The BLM has a stance that if there’s not a piece of paper, it didn’t happen. You have to have documentations of what happened and what devices were used. That’s the first point.
The second point is we all make mistakes. We all collect data. We have tried to automate the process of data collection as much as possible within our provers, so that there’s as few keystrokes as there can be. Even with that, there’s some stuff that’s unavoidable.
These are documents that are going to get sent to a government agency, whether it’s a state agency or, at the very least, something that’s got to back up a contractual obligation. You want to make sure that it’s right. If it’s not right, you want to make sure that you correct it.
We have a process within SPL where we basically validate every proven report that’s done up to almost a thousand of those a week where we crawl through those and look at the data, look for keystroke mistakes.
For example, if a device has a power surge and it drops a temperature on a given run because the analog device blinked out or whatever, we can see that data, we can see that it dropped out. We can see how it impacts the ultimate result.
We do that validation like I said, once a week. We share that information back with our technicians and we use those as training tools. If there are fiscal mistakes there, and there always are, we communicate that back to the customer so that at the end of the day, we get to the right answer.
Your job doesn’t really end…Witnessing on location is important. It is something that needs to be taken seriously so that we have, like I said before, a record or, that somebody can attest to that test and how it was taken in the field.
However, you always have to look at the back end too, and make sure that somebody didn’t make a typo. Those sorts of things happen for sure.
Weldon: Typos. We entered a number on, no! You’ve summed up for us there really loops back around into what you were saying earlier. It’s a matter of having a checklist, stepping through that, and documenting.
If something went wrong in the middle of doing that proving, whether it was the runs, the validation of those runs, whether you had an equipment problem that you fixed in the middle of the process, then repeated it to, to try to reach a pass if you haven’t documented that whole process, you don’t really know what’s happened.
One of the things that I run into is the majority of the time when we prove a meter, we generate a new meter factor. We’ve passed the prove. We have a repeatability. We have a new meter factor. What we do with that meter factor can vary depending upon the contracts, we may begin applying that meter factor going forward from all the new product.
We could have contracts in place or policies in place that say we roll that prove back to the beginning of the month. We could also have cases where we really found and fixed the problem. We rolled out there. We tried to prove. We couldn’t get a pass. We couldn’t get a pass. We find a problem there at the site.
We correct the problem at that site. Then we get a good proof. One of the things that’s critical for us to document, that some folks don’t realize, is we need to document those proves that didn’t repeat. We need to document those failures.
If we had a malfunction, a bad piece of equipment, whatever it might have been, the meter was just cuckoo. The RTD was 500 degrees off. Whatever that is if we correct that on site even if our policy in our contract says we start using a new meter factor at the time of the proving.
If we find a malfunction in equipment, then we have that option under almost every contract or tariff that’s out there to go back and adjust that known error back to when we think it may happen. That documentation is critical and that data review is critical.
Chuck: Yeah, and I try to teach everybody that. There’s no bad data. There’s just data. The data is just an insight into what happened at that moment. I also try to teach our technicians to use copious notes. I have a hard time remembering sometimes what I had for breakfast, much less what I did two years ago, which is what usually happens, right?
We have a customer that will say, “Hey, we’re, for whatever reason, we’re missing prudent reports from March of 2021. Do you have those?” The answer is yes. If there was an issue with that, then without those notes, it’s almost impossible to know what had happened. Notes are very important within proven reports.
To your point, I strongly discourage tossing out reports because there are always insight into what happened. To that point, we keep talking about meters failing, but the fact of the matter is that a meter factor It’s a representation, if it’s done right, it’s a representation of the accuracy of the meter.
If a meter proving doesn’t repeat, that could be an issue with the accuracy of the meter, but it could be something else. It could be no indication at all about the accuracy of the meter. It could be that a pump won’t stabilize. I look at it this way. There’s always three things.
Whenever a meter proving doesn’t pass, it either comes down to was it the prover, was it the meter, or was it the system, the system being the LACT unit. Whenever a meter fails, it’s my job to figure out which one of those three is it. If it’s the meter, that’s a problem. We need to address that.
If it’s the system or the prover, we need to address those, but we need to do it separately. We don’t need to apply that meter factor because it’s not a representation of the meter at that point.
Weldon: Well-put. Very well-put. Would you be willing to share with our listeners a little bit more about, when you’re doing a data review, when you’re going back and auditing existing reports, whether that is a one-time because we know that there’s an issue or whether it’s just a routine review of those, what are some of the things you’re looking for as y’all review those reports?
Chuck: Some of them are pretty basic. Some of them are just this is messing or it’s not. Did a technician forget to put his name on the report? It happens. Those are easy to catch. Things like what we were talking about before — was there an issue during the proving where we lost a temperature transmitter, an analog — that’s a little harder. You have to be looking for that specifically.
What I think the biggest tool is, is looking at control charts over time. For whatever reason — well, I kind of know the reason — the BLM, long ago, put a stipulation where a meter has to pass deviation by a quarter of a percent.
In other words, you look at this meter proving. You look at the last meter proving. If you see a shift of a quarter of a percent or more, something’s happened to the meter. We’ve got to do something about it. That’s not a bad rule of thumb.
However, if I’ve been proving a meter for three years, looking at one previous report is not always the best indication of how that meter performs. If I’ve got two years of data, I like to look at it over two years. What is the meter factor doing over two years?
If you look at it in that way, you’ll see things like is there a seasonal effect. Does this meter prove differently in the summer than it does in the wintertime? By and large, that is true for most meters. It happens differently for different types of technologies, whether it’s a PD meter or a coriolis meter, but you’ll see those trends.
I would strongly encourage people to not just look at the proving in their hand, but also look at the historical data of that meter. Control charts are a great way to do that.
Weldon: We throw around control charts in two different places in the industry. We talk about them from liquid meter provings. We also throw them around with chromatographs. We talk about our control charts from our chromatograph performance.
I don’t know how often we define what a control chart is. Could you give us a little summary about what a control chart is, what data you’re putting on that chart, what you’re looking for?
Chuck: With liquid meters, it’s very hard to compare apples to apples unless you’re looking at suitably similar conditions, if you’re looking at similar flow rates, similar product going through the meter, similar pressures. Temperature, for most devices, doesn’t play as big of a part in this regard, but it can. Seasonal effects can definitely show up.
I like to look at things over time, over large periods of time. I like to look at them during similar operating conditions. This is becoming a bigger issue within the industry. It used to be, when we had a LACT unit, it turned on for a period of time at whatever flow rate it was designed to flow at, at whatever pressure it was designed to flow at. It turned off when the tank was empty.
That was it. It was one set of parameters, all the time. Now, with variable-speed drives, with tankless facilities and all of the different improvements that we made — from an environmental standpoint, those are great improvements, and from an economic standpoint — they present unique measurement challenges.
A LACT unit may not operate at one flow rate. It may operate at a continuum. If you want to properly track the accuracy of that meter, you need to know, is that meter performing the same over that whole continuum?
You may have to prove at, say, three flow rates, a high flow rate, a low flow rate, and a middle flow rate. If you’re going to control chart that, if you’re going to look at that, you have to compare those as they are within those regimes.
Weldon: Good. Good explanation. I like it. What else can you think of on our list that you’d like to share with folks about witnessing and/or auditing liquid meters? I know you’re a wealth of information there.
Chuck: [laughs]
Weldon: I don’t want to launch into another 45-minute mission, but let’s call it…What are the summary comments? Maybe better yet, what are some of the most common misses or most common problems? Something along those lines.
Chuck: The biggest one, for me, is trying to change the perspective on “failed” provings. Provings are a great insight into how a whole system operates. Failures, in that regard, tell us a lot of information, but they’re treated as if they’re a problem. They are a problem in the sense that they need to be addressed, but they’re not a problem to just make go away.
If a meter doesn’t repeat, for example…This is one that comes up a lot, with Coriolis meters specifically. One of the ways, one of the directions that the industry is going is primarily to Coriolis meters and primarily to small-volume provers, for a number of reasons that we can get into or we can not.
Due to that fact, Coriolis meters and small-volume provers don’t repeat very well. Again, going back to before, the industry is focused on repeatability as a standard because the BLM pushes that in the regulations. Really, if we’re looking at this from a statistical standpoint, uncertainty is a better way to look at it.
A lot of times, meters will pass uncertainty but may not repeat. To me, that’s a better indication of how that meter is performing. What we have seen, when you’re taking such a small snapshot…Some of those small-volume piston provers that we have in operation are as small as five gallons. That’s a very, very small snapshot of volume.
It’s not hard to get five runs on a five-gallon pass that will repeat. Are we really representing how that meter is operating when I compare it to a ball prover that may be five barrels? Taking five runs on a five-barrel ball prover, I’ve got 25 barrels versus 25 gallons. Is that really representative?
A lot of times, Coriolis meters get a bad name because of that fact. They may not repeat, but it’s not necessarily because they are inferior devices. It’s because we’re testing them probably in the incorrect way.
One of the drums that I like to beat is around that uncertainty versus repeatability. We really need to get down to, is the meter performing accurately as it can? Is the meter factor we’re coming up with, that we’re arriving at, truly a representation of the accuracy of the meter?
At the end of the day, that’s the job of a prover and a witness, is to determine, when that meter proving fails, is that the case? Like I said before, is it the prover? Is it the meter? Is it the system? If it’s a system, then let’s stabilize the system and retest.
Weldon: Great. I like it. I appreciate what you shared with us today. I know we have a lot of people out there, Chuck, that are in that position like we talked about earlier. They’re sent out to witness. They’re not sure what that witnessing is.
Just as a wrap-up before we leave, what kind of resources are out there? Can you suggest anything to folks that may be in the position of needing to witness? Where can they get some training? What can they find out? Is there something they can do at SPL?
Chuck: We offer trainings. We do a lot of internal trainings for our own technicians, but we have done these role of the witnesses. That can be as detailed as you want. I know that there are other service providers out there that offer them.
Generally speaking, if you’re coming to SPL for that, it’s usually going to be me. That can be as simple as we’ve done that for an hour or two to just talk about some of the high points that we talked about here. That can be as detailed as I’ve done this over a couple of days and really gotten into the weeds about how provers operate and how meters operate. There’s options out there.
The biggest mistake that witnesses make is not knowing their standards. I really would encourage anybody that’s going to be doing witnessing for any period of time to really dig into API NPMS Chapter 4, for sure.
There are other chapters there, Chapter 14, if you’re doing NGL proving, for example. I would really encourage people. I don’t think that that’s a resource that that people take advantage of often enough.
Weldon: I think that, as well as knowing their particular contracts also…
[crosstalk]
Weldon: …BLM specific regulations…
[crosstalk]
Chuck: You’d be surprised at how many times people have asked, “What proving criteria are we supposed to be using?” They don’t know. They don’t know what the contract says. They don’t know if it’s a federal meter. They just don’t know. [laughs]
Weldon: I absolutely would not be surprised by that because I see it all the time. We generally don’t let the folks in the field know what our contracts say. Heaven forbid they know what they’re supposed to be doing.
Chuck: [laughs] That’s for sure.
Weldon: That’s great, Chuck. If folks are not to the point where they can schedule custom training with y’all at SPL or some of the other training avenues that are available to you, I happen to have it on good advice that sometime in September you’ll be showing up in Houston to do a little talk on this very subject. Is that correct?
Chuck: That is correct. I’ll be at ASGMT to talk about this. I also have a liquids fundamentals course that’ll cover meter proving and meter provers. If anybody’s going to be in the Denver area for the Rocky Mountain Measurement Society in August, I’ll be doing a talk there on this idea about uncertainty that we sort of briefly hit on too.
Weldon: If folks needed a three-day crash course in liquids and liquid measurement, they could go to asgmt.com and look at that liquid measurement fundamentals course or they could look at one of your individual sessions.
Chuck: Yes, sir.
Weldon: All right. I certainly appreciate, Chuck, you have a great day, sir. Thanks for being on the podcast.
Chuck: Thank you.
[background music]
Weldon: I want to thank each and every one of you for listening. I hope you found this episode interesting and informative. If you did, please share our podcast with your coworkers, your boss, and others in the industry.
Now, we’ll have a full transcript of this episode and Chuck’s contact information on the show notes on our website, pipelinepodcastnetwork.com.
As always, if you have comments or questions about the podcast, if you have suggestions for future topics, or if you would like to offer yourself up to the podcast microphone as a guest, then send me a message on LinkedIn, or shoot me an email at weldon.wright@fpvprime.com.
[music]