This episode of the Oil & Gas Measurement Podcast explores the evolution of mass measurement using differential pressure devices, with guest David Bell of Bell Technologies.
David shares insights from his extensive experience in measurement, discusses the limitations of traditional orifice plate technology, and introduces advancements like the Center Tap Technology and the TORUSWEDGE. The conversation highlights how these innovations improve accuracy, stability, and reliability across various oil and gas measurement applications.
Mass Measurement Solutions Show Notes, Links, and Insider Terms
- David Bell is President and Founder of Bell Technologies LLC. Connect with David on LinkedIn.
- Bell Technologies LLC, based in Katy TX, is a global leader in helping businesses create and utilize innovative advancements in differential pressure flow measurement. The company combines technology and innovative engineering together to provide solutions to customers in industrial, commercial and consumer markets.
- Orifice Plate is a restrictive device installed in a pipeline for measuring the flow rate of liquids or gases by measuring the differential pressure created by across the restriction.
- Gas Chromatographs are analytical instruments used to separate, identify, and quantify components in gas mixtures.
- Liquid Samplers are devices used to collect representative samples of liquids in pipelines.
- Reynolds Number is a dimensionless number used to predict the behavior of a flowing fluid.
- DP Cell is the wetted element at the heart of a Differential Pressure Transmitter, where the net of the opposing pressures is converted into an output signal.
- E&P (Exploration and Production) also referred to as the “Upstream” portion of oil and gas industry, encompasses the search for oil and gas reserves, drilling, and production operations.
- Produced Water is water that comes up during oil and gas production, often mixed with hydrocarbons and other substances.
- CO2 Capture are the technologies and processes used to capture and store carbon dioxide emissions from various sources.
- TORUS Fitting is patented differential pressure element design device developed by Bell Technologies for measuring fluid flow.
- MAG Meter is an electromagnetic flow meter used to measure the flow rate of conductive liquids.
- Coriolis Meter is a mass flow meter that measures the mass flow rate of liquids and gases based on the Coriolis effect.
- Densitometer is an instrument used to measure the density of a fluid.
- Flow Profilers are devices designed for insertion into a pipeline to mitigate fluid swirl and facilitate the creation of a fully developed velocity profile prior to entering a flow meter.
- Linear Profile is a consistent flow pattern achieved with the TORUS fitting, ensuring accuracy.
- Differential Pressure (DP) Measurement – A method of flow measurement that determines the pressure difference across a restriction in a pipeline to calculate flow rate.
- Custody Transfer Measurement – The precise measurement of oil and gas for financial transactions between parties, requiring strict accuracy and adherence to industry standards.
- Mass Flow Measurement – A flow measurement principle based on the mass of a substance passing through a pipeline, rather than its volume.
- Viscosity – A fluid property affecting flow resistance, significantly impacting differential pressure measurement accuracy.
- Reynolds Number – A dimensionless number indicating whether a fluid flow is laminar or turbulent, influencing measurement calculations.
- Coefficient of Discharge (Cd) – A correction factor in flow calculations that accounts for energy losses due to friction and turbulence.
- Bernoulli’s Theorem – A fundamental principle in fluid dynamics stating that total energy in a steady, incompressible flow remains constant, used in flow measurement.
- Beta Ratio – The ratio of an orifice plate’s bore diameter to the internal pipe diameter, influencing flow calculations.
- AGA (American Gas Association) represents companies delivering natural gas safely, reliably, and in an environmentally responsible way to help improve the quality of life for their customers every day. AGA’s mission is to provide clear value to its membership and serve as the indispensable, leading voice and facilitator on its behalf in promoting the safe, reliable, and efficient delivery of natural gas to homes and businesses across the nation.
- AGA 3 – A standard developed by the American Gas Association (AGA) for orifice meter measurement of natural gas.
- API (American Petroleum Institute) represents all segments of America’s natural gas and oil industry. API has developed more than 700 standards to enhance operational and environmental safety, efficiency, and sustainability.
- API Chapter 14 – A section of the American Petroleum Institute (API) standards that defines gas measurement methods and practices.
- API 22.2 Standard (American Petroleum Institute – Manual of Petroleum Measurement Standards, Chapter 22 Section 2) defines testing and reporting protocol for the evaluation of differential pressure flow measurement devices.
- Custody Transfer Standard Device – A measurement device, such as an orifice meter, used for financial transactions in oil and gas operations.
- Turbine Meter – A volumetric flow meter that uses a rotating turbine to measure the flow rate of liquids or gases.
- PD Meter (Positive Displacement Meter) – A meter that measures fluid volume directly by capturing and releasing fixed amounts of fluid.
- Flow Computer – A device that collects and processes measurement data from sensors to calculate flow rates and other parameters.
- Wedge Meter – A flow measurement device featuring a wedge-shaped restriction to create differential pressure, commonly used in slurry and severe-service applications.
Mass Measurement Solutions Full Episode Transcript
Weldon Wright: Welcome to “The Oil & Gas Measurement Podcast, Episode 41,” sponsored by Enersys Corporation, provider of Muddy Boots Field Operations software, assisting oil and gas operators to implement accurate and repeatable measurement activities across their entire operation, while also simplifying data collection from the field.
Find out more about Muddy Boots at enersyscorp.com/software/muddyboots.
[background music]
Announcer: Welcome to the Oil & Gas Measurement Podcast, where measurement professionals, bubba geeks, and gurus share their knowledge, experience, and likely a tall tale or two on measurement topics for the oil and gas industry. And now your host, Weldon Wright.
Weldon: Hello, I’m your host Weldon Wright with FpvPrime Measurement Consulting. We’re here today with David Bell of Bell Technologies. We’re going to talk a little bit today about mass measurement with differential pressure devices.
David was with us back in October of 2023 for our episode 25, which was titled Beyond the 100-year-old Office Plate. Before we get started in our discussion that is likely to get a little deep on David’s side, possibly. David, tell us a little bit about yourself and your company.
David Bell: I’m a guy that started in the measurement field in 1968 with Marathon Oil in the process of crude oil and refined products measurement. Graduate of Indiana State out of Terre Haute, Indiana, famous Larry Bird School, and our claim to fame.
Anyway, got into the business and worked in field measurement station designs, turbine meters, orifice for gas, just general runs for measurement. Got moved to a company just starting up a company called it Explorer Pipeline.
In that process, the manager of operations put me in with the engineering department to help design all of the meter stations that they had on the new pipeline. Then I was given the opportunity and requirement by the manager to check out every meter station to make sure it functions and complied with client requirements and our requirements, and teach everybody about how to measure refined products.
In that process, but then later down the road, I was enhanced to move to the Houston area to go to work for a company that made meter stations. In that process, we built custody transfer stations, tanker unloading air elimination stations, they all dealt with, in those days, PD meters, because that was really the key, the turbine hadn’t really come on to play yet in the liquid side.
Of course, at that time, the gas marketplace was strictly orifice plate measurement. In that process of these years, up until about 2004, I had worked for the major companies, Daniel Industry, Fisher Controls, other types.
My background base-wise is across, I guess you could say the spectrum, of the world of measurement from the mechanical side starting and proving meters to the electronic side dealing with flow computers, and where they went from power driven in a control room, to remote solar paneled units, whatnot in the field.
Plus, then I moved into a company called PGI, which was hand valves and manifolds. Which was a help to the industry to eliminate some of the problems. I got into the leading edge on a lot of stuff throughout the years.
In ’04, I had an idea to design and build a primary device to take away a lot of the problems that the orifice plate had that we talked about back in the ’25 session about what’s gone beyond what is out there now and whatnot.
In that process, we built this called a Taurus Wedge. A Taurus Wedge was basically with designs of a venture, an orifice plate, and no sharp edge. Measurement of the upstream, downstream P1, P2 location for differential pressure and raise the coefficient of discharge with viscosity Reynolds numbers requirements and up into the Venturi range, into 0.9 accuracy range. In that process, this was a in-between an orifice plate and a Venturi or a flow nozzle.
Did well in the drilling industry because it handled drilling muds, sand fracks, severe service due to its geometry design. This design can be seen on my website if they wanted to go look at it, at www.belltechnologiesllc.com, and it’ll show up the growth in the timeframe of what we’ve been through.
As I was building this and when I served some time at Daniel Industries, I met a guy by the name Zaki Hussein. Zaki is a PhD gentleman from Bangladesh, graduated from high school, came to University of Houston, got his master’s degree in doctoral degree from the university. He taught at the university for about 16 years on mechanical engineering.
Then he was asked to move into a company called Texaco. In 1983, prior to his move to Texaco, he was working for Daniels at the time. They ran a test that was very unique in its respect. The question was, what is the pressure in the center throat of the orifice plate?
They ran this test in ’83 and found that the differential pressure reading was very stable when you read upstream P1 and center throat P2 versus P1 regularly and P2 downstream. There was a tremendous difference between the two differentials. They did that, but it was never brought to commercialization to do all orifice plates that way.
That technology was put on the shelf for quite some time. After Zaki retired…When he went to work for Texaco and then Chevron bought them, Zaki became the supervisor of the measurement group on the corporate side of the issue for Chevron worldwide. He was there 20 years.
When he resigned or retired, whatever it was, he came to me and said, “I have this technology we developed in ’83. I’d like to put it, because it’ll fit in your meter that you’ve designed, and I think we have something good to go.” We did tested it. The testing results was phenomenal. We did that.
That developed a technology that was really developed after 2017 called Center Tap Technology. When you take the pressures at the locations, the influences of the flowing stream have a major impact. When you take it in the throat of the restriction where everything is compacted, the velocity is at the fastest, the pressure’s at the lowest, you get the most stable reading, no matter what the process is.
The process can be drilling muds, it can be pure gases, it can be wet gases, it can be crude oils, it can be refined product, water, produced water, whatever. It is a very simple way of taking the best differential, and it eliminates a lot of uncertainties that are in the world of differential measurements. With that, and the Center Tap technology that was developed, we ran this on all types of processes.
The processes were drilling muds, natural gas, crude oils, salt water, slurry fluids, and then we began to look at different things because we noticed that, in typical orifice differential flow measurement, the problem typically is each device that’s there differential wise is a mass meter.
That’s the way physics has designated this meter, is purely mass. We do a lot of calculations to do the change from mass to volume flow, or to BTU value flow, in the process of changing dollar value between one client to another.
We learned, over the time, that the major impacts within the problem for everybody is viscosity of the stream, Reynolds number of the process, and the coefficient of discharge for the particular geometry designs of the differential devices.
In that CENTER-TAP technology, since we could get very stable with its output, we began to investigate other areas and we figured out, in other areas of development and testing, we could do a lot of things that had never been able to be done before. We took the CENTER-TAP technology and applied it to the full API database that was used to do the current calculation in Chapter 14.
In that, they did 10,000 data points from four different labs around the world, compiled it all together, and came up with a calculation that has a built-in error of, I believe it’s 0.543. It’s in the standard that goes into play that you have a built-in error in any differential device that equates itself to an orifice.
All of us do that because, if it’s an annulus, we size it for a beta ratio. If it’s an orifice plate, it’s a beta ratio. All of the things come into play. That viscosity tends to be the standout problem because it has the influence into a lot of things. The differential pressure, Reynolds numbers, coefficient of discharges, all of that is influenced by the viscosity.
If you get into Bernoulli’s theorem, Bernoulli’s theorem on the conservation of energy is the physics behind all differential flow room. In that process, you have to know all of those and you have to put them into a flow computer that does a lot of the integrations — temperature, density, viscosity — and generate to get a volume output a very accurate output as we know it today.
Weldon: David, let me interrupt you a second. Let’s rewind just a second. You said something minutes ago I’d like to stop and talk about a little more here, and that is the concept that I don’t think a lot of folks in today’s custody measurement. I’m putting my fingers up for the air quotes on custody transfer measurement here.
Our custody transfer measurement with an office meter, we’re working on data, we’re working on calculations that are 100-plus years old now, the basis of. We’ve improved on some, but the root of all of those calculations is mass flow, right?
David: Yes, sir.
Weldon: We don’t talk about it. When I teach classes and measurement fundamentals, I don’t teach people that these are mass measurement devices because we’ve spent a hundred years telling people, “No we calculate flow from them.”
But what’s really happening in the background, all of the equations, all the physics are based upon mass and velocity, what’s going down that pipe, that energy. Then only after we get that buried deep inside of our AGA 3 equations, then we turn that into a volume.
Our existing orifice plates, our existing orifice meters, our air concentric, flat, square edge orifice meter that AGA 3 talks about, that we use as our custody transfer standard, it’s really mass measurement. Then we take some approximations or some guesses about viscosity and a few other things and try to turn that into a volume.
David: You’re exactly right. Yes.
Weldon: On our podcast here, we focus, majority of the time, on that custody transfer measurement in oil and gas, right?
David: Yes, sir.
Weldon: But custom transfer measurement is only a small piece of all the measurement we do in the oil field and on the pipelines, right?
David: Exactly.
Weldon: When we talk about custody transfer measurement with an orifice meter being that square edge…
David: When you’re talking about the square edge, the square entrance point has to be a sharp, 90 degrees square edge.
Weldon: When we talk about that device as our typical office meter, it’s only our custody transfer standard device because we’ve piled, like I said, over 100 years of research into it. When we start talking about your version of a differential pressure meter, we’re talking about the same technology that comes to us — not same technology — same math that comes into wedge meters and other type meters like that.
David: Exactly.
Weldon: This is not a new concept. It’s just not the concept that we use because we have that warm fuzzy, right?
David: Right. If you take an orifice…The orifice plate itself is required to be X thick. The only thickness requirements for that is how much differential pressure it will withstand before it starts to distort, bend, wear the sharp edge off of it, things that change the accuracy of the device, and so you have that inspection period.
The technology that we’ve learned over the years, the idea that I got for the TORUSWEDGE was from a gentleman that had built a wedge meter that is nothing more than a dent in the pipe to develop a differential pressure so he could flow and measure iron or slurry, very severe service. From that, the technology was developed to make it like an orifice plate.
The TORUSWEDGE is a 360-degree wedge meter, like an orifice. In that process, we have flow profilers built into the throat or the beginning of this TORUSWEDGE because it is a 360 45-degree ramp that conditions the stream to the throat.
Its launch point, at where the sharp edge of an orifice plate would be, which is a flat 90-degree from throat to face of the plate, mine is a 45-degree, so I don’t wear the edge of the entry out like you would an orifice plate because the energy is passing over the top of it. Never impinging on it.
With that and the Bernoulli’s theorem, the way we calculate flow today with the use of Bernoulli’s theorem, then basically we have to have all those impacts. What Zaki did was he looked at a different way of taking flow physics and figure out a way to measure the energy throughput.
We’re measuring energy through, so our change is away from the 100-year-old calculation that’s been upgraded multiple times in that timeframe to make it better. This is a looking at flow physics in a different light to be able to have P1, which is potential energy and P2, which is kinetic energy.
P1 is taken upstream and P2 is we’re taking it at the best place physics says to take it, at its lowest pressure point, highest velocity through the restriction. That’s where we’re at with the center tap.
To calculate that and eliminate some problems that everybody has, and that’s viscosity of the stream, gas has a little change in viscosity, but can be a major percent of uncertainty created if you’re not knowing the exact viscosity of the stream itself.
Granted, there’s that zone that you can accept a spoonful of sugar and be happy with it. But, if you’re looking for accuracy and knowing that you’re not giving away product by selling it because it’s under-reading or you’re gaining it on the other side because you’re not having to pay for it, it has to be looked at for honesty on inlet and outlet.
In this, the geometry design of the Taurus wedge, it helps eliminate a lot of mechanical problems of the orifice. That development has been proven under all kinds of applications. Can supply anybody that wants any of the data. We have complete data tests on everything from 1 inch through 20 inch. In that, that supplied, I give you the data, you can look at it.
Then, during COVID, Zaki came up with the way to basically eliminate the problem causers in a lot of measurement in the mass side, or in the volumetric side, in the differential area through Bernoulli’s theorem. That’s to measure the energy. We call it the energy correlation calculation.
What it does is it doesn’t require you to inject the viscosity of the stream. We’re not trying to develop a coefficient of discharge from it. We don’t need the Reynolds numbers of it. We don’t need the temperature or the pressure that it operates at, because mass eliminates all those outside features.
A pound is a pound, a pound of feather is a pound of feathers, a pound of feathers has gone on throughout years that nobody’s ever really utilized for flow. This takes that area and says a pound of gas is a pound of gas, and we flow, that did, and that took X number of times when it was reported and the change and everything.
Every differential meter out there, once it goes through this energy correlation calculation, it basically produces a laminar flow. A laminar flow or transitional flow or all three phases of flow are now looked at in a different respect because we can take this device with this calculation and we don’t care what the stream is doing, whether it’s in any one of the three integrations that is currently out there on fluid flowing through a pipeline.
Doesn’t have any impact on us. Viscosity doesn’t have any impact. The meter itself is a linear profile. This linear profile gives us, be able, since we have flowing density, and we have delta P. The accuracies of those devices are what they are given to us at. The calculation actually puts these under the square root function, so they’re half of the error that we’re getting. It eliminates some more uncertainty in the calculation.
We’re doing an energy calculation for mass or volume. It can be Change the volume so it doesn’t upset contracts the way everybody reads today, but they’re actually measuring it in the best way to measure any flow, and that’s its mass weight.
Weldon: To back up a minute there, David, again, you brushed over something that’s super important in this. In our office measurement, whether we’re measuring natural gas or whether we’re measuring fluids, maybe CO2, regardless of what we’re measuring, we spend a lot of time assuring that we have that well developed, mature flow profile in that pipe, right?
David: Yes, sir.
Weldon: It can’t be too smooth, can’t be too rough, definitely can’t be turbulent, right?
David: That’s right.
Weldon: That’s one of our enemies with orifice flow, right? The big ones out there are, if you have anything other than nice pretty gas, we erode the orifice plate. OK?
David: Yes.
Weldon: Then we have to do all this work, design work, we have to insert flow conditioners. We’ve got to make sure that we have a mature profile. Back up a minute, and let’s touch…You talked about, you didn’t care which of the three flow states we were in. Let’s elaborate on that a little bit more.
What you’re saying really is, your device is the flow profiler, and you don’t really care what it looks like coming down the pipe towards you, do you?
David: No, sir. It is the profiler because, currently, if you looked at a meter station, gas meter station today, or even a liquid meter station today. The first thing out, we have to get the stream conditioned to be flat faced to enter the meter.
In that flat face, you’re able to approach a turbine meter on the blades without any turbulence or energy forcing the rotation of the blade to accelerate due to the density change, due to the energy that’s on, say, the right side of the meter.
We go back upstream on turbine meters, on ultrasonic meters, on Coriolis meters now, and orifice plates to put a some type of conditioner to, if you came out of an elbow, you’re high pressured on the outside edge of the elbow, low pressure on the inside of the 90.
All of a sudden, your energy It can create swirls and approach the orifice plate, or any meter, on more energy on the left side than it is on the right side. You need to basically flat face that energy for all meters that don’t condition the stream, to be able to see a stable stream.
We’ve gone through millions and millions of dollars and really good technology at the time to develop these devices. There’s three or four or five of them on the market that do a really good job, but they are designed so that they’re trying to bring all of the energy to the center of the stream, practically based on the bore of an orifice plate.
So that we can get, without any disturbance, we can get a stream that flows through the center throat very stable. In our condition, what we’re doing, it does the same thing in a Venturi. When you have an inlet ramp on a Venturi, it’s roughly somewhere around 35 degrees in through the throat, and out to a cone on the outside that controls the distribution of the stream so that it gets easily put back on to full face flow downstream.
Our case, we’ve tested meter after meter, different designs, cone up front, different angle cones up, different angles down, center taps, about anything you can think about. The stream performs this way, that if I have a 360 degree conditioner that pulls the stream stably to the throat, I don’t have a sharp edge. I don’t need one.
I can handle, because of the design of the device, a tremendous amount of differential pressure. I can handle line pressure differential, if you want to go that far. Then the outlet can either be flat faced, or it can be coned outlet, depending on what you’re doing, what’s the process, what accuracy do you want to achieve in your device.
We can, at that point in time, influence with this profiler and its condition. We can influence the mixture of the stream for the sampling industry. We develop at the outlet of the ramp, in this meter, a very stable homogeneous mixed stream that comes out through the throat. We are now working on wet gas to be able to sample wet gas at the full stream. That is in an API committee that’s being worked on today.
Weldon: That’s going to make people’s heads explode. You want to sample wet gas and you want to mix it well before you sample it. Get a [inaudible 28:38] representation. That’s going to make heads explode on the committee, won’t it?
David: We know that whereas Zaki developed the dimension in the ’83 tests that I talked about earlier about, the center tap of the orifice plate, he also found out that the stream does not reattach itself to the full face until it’s about four and a half diameters downstream.
Since early ’90s, nobody’s ever been able to put a probe downstream of a restriction, any type of differential device, and take the information you’re looking at there, gas chromatographs, composite samples, hotspot samples, anything like that. Temperature probes, pressure probes, because it disturbs the differential pressure on a orifice design device.
He looked at it and all at many different beta ratios and different pipe sizes. He was able to determine that roughly four and a half diameters downstream of the primary DP generator, was where the stream reattaches for any beta ratio. Betas 0.7, little betas 0.2, all of these were at four and a half diameters.
The sampling system goes down there, and that’s where the sample is taken. At the time, we were running under the analysis that natural gas is dry, pure, clean, not dirty, not wet, and so that’s where we need to take the sample from.
Then as age of wells change, water or hydrocarbon gets, in the mist, gets in liquid form, whatever it is, traveling down the pipe that gets passed through this differential device, drops out of the zone area that they are able to take gas, chromatograph feeds, sampling feeds, anything that they’re looking for to take a number from. They ended up having wetness in mist form in natural gas.
They end up putting a membrane on the chromatographs because they can’t stand liquids and dry chromatograph functions in the stills that they’re running inside because they ruin them. You can’t analyze the gas sample at that point, so they put a diaphragm on it. Great idea, worked fine.
In today’s world, the wells that are being produced are wet. You see a lot of pipeline transmission companies get in tune with the old stripping plants that I was highly involved with through Fisher Controls back in the old days, whether they were refrigeration or JT-type devices.
Basically, in the process, they take the liquids out of the pipeline, condition it, sell it to the chemical plants and refineries for a feedstock. It’s great for them, but it’s bad for the producer because he has to extract that value out of what he gets paid. He doesn’t get paid for the liquids.
That’s become one of the issues on the sampling group, is that the patch, we’ll call it, that, is putting the pressure, let’s find out what we need to do. In that, that’s where this sampling program is being funded by the API to determine what the standard should be as to sampling.
Weldon: We’re all interested in seeing what comes out of that because, as you’ve alluded to, we’ve stuck our head in the sand on that aspect of sampling for a long time. Our standpoint on that wet gas has been to declare your gas can’t be wet, so we’re going to do everything we can to reject any liquids in there before we take a gas sample.
David: I look at it this way, yeah.
Weldon: That gives a lower value to that producer.
David: There’s always an old saying in the pipeline industry, if you’re handling natural gas, “If you’re higher than seven-tenths of a percent of parts per million, we’re going to shut the valves off of you because we don’t take the wet.”
I said, “If it’s seven parts per million and you’ve got a hundred injections in this pipeline, how much wetness do you have in the pipeline?” Because there is.
You remember back in the days when we had a western company, had a 30-inch pipeline that blew up, and it killed about 30 people at a campground. The federal government walks in and says, “You will put cleaning devices in your pipeline to clean out the pipeline. You have to put launchers and receivers in your pipeline.”
Everybody in the industry went through about five years of quickness to reinstall launchers and receivers to put smart pigs cleaning run spheres, scrapers the whole bit in the pipeline to keep it clean because there was corrosion inside created by the wetness. It was coming out of the gas they were transmitting.
Just a logical step from one to the other to the other. That’s what Zaki and I have done with this measurement capabilities, with this CENTER-TAP technology and the energy correlation calculation. It’s one of these steps forward to make things easier, better, and more accurate.
Weldon: That’s what we should all be about in measurement. We need to improve where we can improve. If we can improve and be more cost-effective, that’s really the holy grail of everything. We’re going to have to bring this in for a conclusion here in the next few minutes, David. Do you have any thoughts to wrap this up?
One thing I’d like you to mention is, throw out just a little bit of discussion, not more than a minute or two, hopefully, about how the comparison is going with your product versus the cost of installing coilovers measurement, for example, which is where a lot of companies are heading in their CO2 in our liquids world.
David: If you took it and looked at, let’s take a generic Coriolis meter, I don’t care who’s manufacturing it, whether it’s a single tube or a double tube Coriolis meter. The problems that we see with those devices that are now being proved to happen in the field is if they’re on a single phase fluid, they’re very good, outstanding device.
If they have a issue where they have a liquid and the changing of pressure allows the gas that’s in the fluid to expand. Then the Coriolis meter, because it’s a resonant frequency device, it’s got a movement to it, and they’re using the throughput energy of the stream to resonate against the range that they’ve been calibrated on.
They actually wait, stop their reporting, wait till the stream is recognized back in their range of fluctuation in their pipe due to the energy throughput, and they come back on. They’re very good.
In the ultrasonic side of the issue, comparison-wise, they are relying on sound waves. If I have a wetness in the gas, it distorts the sound wave. It just quits for a time being until that liquid slug or wet gas gets downstream and it starts to work again. That’s great. That’s fine. That’s the way they’re designed, and that’s the way they work.
In our case, we don’t have a moving part, we don’t have any sound waves. We’re actually using the energy to push the stream through, and the energy is the only thing that is now being measured.
When you simplify it this way and you can now add a second transmitter to do self-diagnostics on our orifice restriction design, which none of the orifice fittings, single- or dual-chambered, OFU, or whatnot do a second transmitter to do diagnostics on it so that you know when the orifice plate failed, when something failed with the transmitter or whatnot that is reporting the information.
When you do diagnostics, and you can now give them two different pressure differentials, which equate to volume throughput when you look at it, but both of them are producing the same flow rate if you look at them and do the calculations on where they’re at and whatnot.
Then you see that you can have a parallel run between the transmitters, and once there is a distortion that comes about, one separates from the other, you can integrate into your electronic controls a alarm point.
If this alarm point is over a certain period of time, you send out an alert, we got a problem on meter so and so, or you get it to a point where they say, “I know that there’s a problem from A to B,” and so we go get rid of the problem.
In the cost factor side of the issue, because my device is basically 50 percent the cost of a expensive Coriolis ultrasonic as an example, and I won’t mention hood is, but there’s a bidirectional 20-inch gas pipeline in West Texas that had a four-inch Coriolis meter associated with it.
In that process, they were using a check meter to determine the bidirectional flow of the pipeline. One was almost a billion cubic feet a day, and the other was backwards was about a half a billion cubic feet a day, so in each direction.
We put a center tap technology in that pipeline in between a pair of flanges is our design, sets in there, and it measures both ways. In that process, just to give you a dollar comparison, I found out how much they had in the budget for the ultrasonic meter station bidirectionally.
It was $330,000 to install at a ultrasonic check meter. They install my meter for $20,000. That gives you a little feel in the Coriolis marketplace in the mass meter, we’re about 50 percent of what the Coriolis will be.
Weldon: David, I think that’s a great point to draw people’s attention to the fact that this is a technology worth looking at and worth considering.
David: Yes, sir.
Weldon: We could go on for this probably for a couple more hours but we need to wrap this thing up. Tell us very briefly, how do people get more information? What’s your website? Where do people go to get more information about your product and your technology and the testing that you’ve done?
David: Testing we’ve done at CC both in Colorado and on the main line in Iowa natural gas. We do testing at Alden Labs in Massachusetts. It’s one of the oldest water flow labs in the country. They do everything from about 2 inch to 48 inch. We get everything that we do.
We recommend for the first meter that any company uses, we go out and they pay for the calibration so they know exactly what that meter does in the configuration they’re going to install it in.
Weldon: All the information, your testing, your technology is available on your website, right?
David: Yes. Testing is. Available. The website is www.belltechnologiesllc.com. Then they can contact me and we’ll get all the data necessary. What we need on what they come to me and ask me for a meter, I need to know the operating pressure, the operating temperature, the flowing density, and the line size that they’re running in.
Those conditions right there, we’re able to take and determine our rate bay ratio, which is only three that we produce, so that’s 0.3, 0.5, and 0.7. We do specials like the one I was talking with earlier. Basically we’re doing CO2 out of fermenting pots with a three millimeter bore on a one-inch pipe.
That and my phone number, they can get ahold of me by phone 832-746-7179. Or they can send to my email at dbell@belltechnologiesllc.com, or they can send it to my personal email at jdbell@sbcglobal.net.
[background music]
Weldon: Thank you so much for being on the podcast this month, David. A lot of information here and I encourage people to get out and take a look at it. Thanks again, sir.
David: Weldon, thank you very much for the invite. I appreciate it and wish you a blessed day. Thank you.
Weldon: I hope you’ve enjoyed listening as much as I’ve enjoyed doing this episode. We will have David’s contact information along with the full transcript of this episode in the show notes on our website pipelinepodcastnetwork.com.
If you have any questions about this episode, if you have suggestions for future topics, or if you’d like to offer yourself up to the podcast microphone as a guest, send me a message on LinkedIn, or shoot me an email at weldon.wright@fpvprime.com.