This episode of the Oil & Gas Measurement Podcast features an interview with Landen Beckham from e9 Treatments. The discussion centers on e9’s molecular coating, which is designed to reduce buildup and fouling on oil and gas measurement equipment, and how it can extend the operational life of meters. The conversation covers the benefits of this treatment, with a focus on its application for mag meters, Coriolis meters, and provers.
Molecular Meter Coating Show Notes, Links, and Insider Terms
- Midstream: The segment of the energy industry that involves the transportation, storage, and wholesale marketing of petroleum products and natural gas.
- Upstream: The segment of the energy industry that involves exploration, drilling, and production of oil and natural gas.
- Downstream: The process involved in converting oil and gas into the finished product, including refining crude oil into gasoline, natural gas liquids, diesel, and a variety of other energy sources. The closer an oil and gas company is to the process of providing consumers with petroleum products, the further downstream the company is said to be.
- Small volume provers – A type of calibrated equipment used to verify the accuracy of flow meters in the field. The guest, Landen, has a background in building, servicing, and operating these.
- Water draw trailer – A mobile piece of equipment used to perform a “water draw” calibration, which involves using a known volume of water to test and verify the accuracy of a prover or meter.
- Permian Basin – A large sedimentary basin in the southwestern United States known for its significant oil and gas production.
- LACT unit – An acronym for Lease Automatic Custody Transfer. It’s an automated system that measures and samples crude oil during a transfer from a lease site (the well site) to a pipeline or other transportation method.
- Coriolis meters – A type of flow meter that measures mass flow rate directly by using the Coriolis effect. The podcast discusses treating these meters to prevent buildup and maintain accuracy.
- Produced water – The wastewater that is a byproduct of oil and gas extraction. It often contains a mixture of hydrocarbons, dissolved solids, and other contaminants.
- Mag meters – Short for magnetic flow meters, these measure fluid velocity using magnetic fields. The podcast highlights how the guest’s company has had great success treating the electrodes within these meters to prevent fouling.
- Surface energy – A scientific term referring to the amount of energy on a material’s surface. In this context, it describes how easily contaminants and other substances will stick to a surface, with a lower surface energy being more resistant to buildup.
- Molecular level – This refers to the scale of atoms and molecules. The guest explains that their treatment works by chemically bonding to the oxide layer of metals at this microscopic level.
- Nanometers – A unit of measurement for extremely small lengths, equal to one billionth of a meter. The guest uses this to describe the thickness of their treatment molecule, highlighting how it is not a thick coating.
- Thermal mass meter – A type of flow meter that measures mass flow rate by detecting heat transfer. The guest mentions they have treated one of these for use on a flare system.
- Flare – A process in which excess natural gas is burned off at a wellhead or other facility. Thermal mass meters are often used to measure the flow rate of the gas being flared.
- Orifice meter – A device used for flow measurement that restricts fluid flow using an orifice plate. The podcast mentions issues with black powder and salt deposits fouling these meters.
- Custody transfer measurement – A process where fluids are measured for sale. The measurement must meet strict standards set by regulatory bodies because the quantity determines the monetary value of the transaction.
- Ultrasonic meters – A type of flow meter that measures the flow of a fluid by transmitting ultrasonic pulses. The podcast mentions issues with these meters fouling on the inside.
Molecular Meter Coating Full Episode Transcript
Weldon Wright: Welcome to episode 47 of the “Oil & Gas Measurement Podcast,” sponsored by EnerSys Corporation, provider of Muddy Boots Field Operations Software, assisting oil and gas operators to implement accurate and repeatable measurement activities across their entire operation, while also simplifying data collection from the field.
Find out more about Muddy Boots at enersyscorp.com/software/muddyboots.
[background music]
Announcer: Welcome to the Oil & Gas Measurement Podcast, where measurement professionals, Bubba geeks, and gurus share their knowledge, experience, and likely a tall tale or two on measurement topics for the oil and gas industry. Now your host, Weldon Wright.
Weldon: Hello. I’m Weldon Wright with FpvPrime Measurement Consulting. Today, I have Landen Beckham with e9 Treatments on the line with me today. We’re going to talk about how do we reduce buildup, how do we reduce problems that occur inside of our equipment because of the stuff we’re sending down the lines we probably shouldn’t be sending down?
Landen, welcome. Tell us a little bit about yourself and tell us what in the world e9 Treatments is about.
Landen Beckham: [laughs]
Landen Beckham: Good morning, Weldon. I appreciate you having me on. I’m excited to talk to you about all this exciting stuff. First off, my name is Landen Beckham. I’m sales director for e9 Treatments.
A little bit about myself. I come from East Texas, so the Tyler area. I graduated from TJC, Tyler Junior College. Then I originally got my bachelor’s degree at the University of Texas at Tyler. I got that bachelor’s degree in marketing. Then I found the oil field.
I got an opportunity, 2019, to go down there to Houston. I worked for flow management devices for about three years. I built, serviced, and manufactured small volume provers. It’s my base knowledge that I got in the measurement field of oil and gas. I traveled all over the country with a water draw trailer hooked up to our small volume provers, water draw them, and got a really good baseline.
Then I got the opportunity to go out West. I operated a proving company in the Permian Basin for two years out there. I had a fleet of 8 to 10 small volume provers on trucks running around and proving LACT unit, Coriolis meters all over the Permian Basin.
After about two years, the wife’s like, “Hey, I think it’s time to come back home. You’re here away way too much.” I learned about e9 Treatments. I was very intrigued with what they were providing as far as a solution to customers on the buildup and just the meter gunk that can happen in the line.
We started talking there. I thought it’d be a great transition to bring my knowledge of measurement as a whole and how it would really benefit customers in the long run to treat those meters and keep all the gunk off of them and keep them in tolerance for longer periods of time. That’s a little bit about me.
When I’m not traveling the country and treating devices, I’ve got a beautiful wife, Demi, at the house and a six-month-old, Dawson. Life’s a little wild right now. We got a little boy about to be walking and running. Just trying to brace myself.
Weldon: All right.
Landen: Yes, sir.
Weldon: I can relate to the “It’s time to come home.” In my early career, I did a lot of travel. Feel sorry for those people.
Landen: [laughs]
Landen: Tell us a little bit about e9. What are they? How long have they been around?
Landen: Let’s talk about e9. e9 is an actual parent company of a larger company called Electrolab. Some of you may have heard of us. We’ve been around since 1976. We provide level sticks and production tanks. Our level sticks utilize floats that float up and down depending on the level that’s in the tank.
In 2010-ish, we were having some issues with customers having the paraffin buildup on the actual stainless steel rod that was keeping our floats from operating correctly. They’re having issues with them sticking. They’re calling us. We got to find a solution for that problem.
We hired Ajeeta Patil. She is actually our product technology director. She is the mastermind behind the molecule itself. It took us two years to fine-tune this molecule and get it to where we were happy with it. We started treating our own level sticks in 2012, 2013. We spent two years treating our level sticks. We treated about 10,000 of them out the door. Not a single one of them came back.
We’re like, “We got something.” We don’t really know the grand scheme of where we can take this, but we do know that applying it to the oxide layer of a metal in an oil and gas production operation can keep that junk off of it.
I was hired on two years ago. I’m bringing this to the midstream measurement world where this product needs to be. This product needs to be on flow meters, densitometers, small volume provers. Anything that requires to stay clean, to stay in tolerance, to give you the best measurement possible, I believe, needs to have our treatment on it to protect it for the longevity of its life.
Weldon: I feel insulted. Are you implying that all of the stuff we put through our hydrocarbon liquid and gas measurement meters is not fine, pure, and contaminant-free? That’s sacrilege.
Landen: [laughs]
Landen: We would all like to think that we’ve got the perfect process conditions and everything is ideal. Unfortunately, we can all agree that sometimes there’s stuff that goes through that line that we don’t want in there.
Weldon: Not in terms of the engineer that designed it and not in terms of the guy that sets the budget for our field operations group. I know that from experience.
I guess where you’ve got the most traction right now and where I heard of e9 the first time is with friends and coworkers in the industry that are dealing with saltwater disposal and understand, from what we talked about before we started the recording, that about 80 percent of your current business is around mag meters in the water world.
Landen: Correct.
Weldon: You want to talk a little bit about that and…
[crosstalk]
Weldon: in that area?
Landen: Absolutely. A lot of our core business, especially treating meters-wise, is around the mag meter world. With the produced water side, as the produced water becomes a more important commodity for people to measure, we need to make sure that these meters are clean and operating correctly to limit the crazy variances that a lot of these fields can see.
Let’s talk about a mag for just a second. If you haven’t had a chance to look into one, basically a mag meter consists of a Teflon liner. This Teflon liner has a really low surface energy, does a great job of keeping everything off of it. It’s also got electrodes internally. Depending on the meter, it could have four, six, eight. Just depends on what model you get.
These electrodes are the most important part of this mag. They are what send and receive the voltage that gives the meter the flow rate to basically tell you how much water is going through that meter. The biggest issue is these electrodes are made out of stainless steel, or 316 stainless steel. Compared to the Teflon liner, it has a much higher surface energy than it.
If you’ve ever got downtime, if that water is just stagnantly sitting in the pipe, it gives a great opportunity for those foulants and all those hydrocarbons — like we said, it’s not a perfect water; there’s all types of junk in it — to begin to bond. When it begins to bond, the electrodes are the first thing that begin to see that buildup.
We go in there. We ensure that the meter and the electrodes are absolutely spotless clean. I treat it with my solution. My chemistry protects those electrodes from all that nasty buildup. It actually lowers the surface energy lower than the Teflon. There is absolutely nothing internal in that meter that wants to receive all that nasty gunk and buildup.
That is a huge core business. I’ve been treating mag meters for well over two years now. I’m telling you, if you have a mag meter, it needs to be treated. It is an absolute home run, especially in the produced water world, which can be some of the most challenging process conditions that there is out there.
Weldon: Let me loop back around to something real quick. You threw out a term that I’m a little aware of. I know I need more education about it. I suspect that’s true about most of my listeners. Talk to us about the term surface energy. What does that mean?
Landen: Surface energy basically just means on the actual surface, when products and contaminants come in contact with it, how easy is it to stick and bond to that surface? That’s why Teflon is utilized in a lot of these water meters, because it has a tremendously low surface energy. Things just slough off and don’t necessarily bond to it.
The surface energy is a big thing that we talk about a lot. That’s what e9 is here to lower that surface energy of metals so that they can deter all that nasty gunk inside the pipe.
Weldon: You’re talking about something happening at a molecular level?
Landen: Yes. Correct.
Weldon: Not just “we’re sticky.”
Landen: Correct. Absolutely. Yes, sir.
Weldon: Back to our regularly scheduled programming. You were telling us about the need for treatments in mag meters in this dirty water world.
Landen: Correct.
Weldon: Why do they need your product? What are you doing for their product?
Landen: What I’m capable of doing is I’m capable of extending the run time of that meter. I’ve treated thousands of mag meters over the last couple years. I’m comfortable telling you right out of the box that I’m going to 3 to 5X whatever your maintenance cycle’s been. If that mag fails and your variances go crazy by a month, we’re going to make it last three.
A lot of times do I see 5, 10, 15, 20X. Are there locations that a meter was fouling every week and now we’ve gone six, seven, eight months? Absolutely. That’s why we’re here, is to extend that maintenance. By keeping those electrodes clean, we’re able to increase the accuracy of that meter and just keep it operating in spec for much longer periods of time.
Weldon: As we talked about a little bit before we started the recording, in the measurement world, we don’t like to talk about those things, about regular maintenance at all. In our minds, we want to pretend they last forever. We’ll say, “Oh, I’m going to go inspect my meter.”
When we get into the gas world even, we have requirements for periodic inspection. The only reason we’re inspecting is to see if we need to clean the darn thing. In the saltwater world, that’s just a common thread I hear from everyone I talk to in that world about the fouling.
Landen: Correct.
Weldon: They foul up stuff to where it doesn’t work within a mere matter of days sometimes.
Landen: That is correct.
Weldon: Natural gas, it takes us longer, but we still have a lot of the same problems. Back to your saltwater world. When you’re going in and treating these meters, I know this is not going to be a permanent treat, but you can’t guarantee it lasts the life of the meter. Talk to us a little bit about what’s actually happening to that metal and how long you expect a treatment like this to last.
Landen: Absolutely. Let’s talk about the actual molecule itself for just a second. I just want to give you a base understanding of what the molecule is actually doing with the oxide layer of the metal. I’m a metal treatment. My molecules chemically bond to the actual oxide layer. We are not a coating. We’re not a Teflon where we’re just sitting on the actual surface. We are chemically bonded to the oxide layer.
My molecules are 3 to 10 nanometers thick, so tremendously small. Think about a piece of paper. If you looked at it, that piece of paper is 100,000 nanometers thick. We are absolutely very, very, very small. You would need a very strong microscope to be able to actually see us on that surface.
We self-assemble ourselves, depending on whether I’m spraying and wiping it on, whether we are filling up a Coriolis meter to the top with it. They self-assemble themselves on the oxide layer. Basically, like we talked about earlier, lowering the surface energy and protecting that oxide layer from all that nasty buildup that wants to be there.
Weldon: Things happening down there literally at the molecular level.
Landen: Correct. That is correct. Yes, sir.
Weldon: How long does something like that last? I assume that’s a really loaded question, depending on what’s going down the pipe.
Landen: Correct. That’s the million-dollar question. I get that at every trade show. I get that at a new customer meeting, stuff like that. Everybody wants to know how long do I last. It’s an absolutely loaded question, like you stated.
The way I like to go about answering that, is everybody’s process conditions are different. What a mag meter at this location sees, one, two miles down the line might see something completely different when it comes to temperatures, pressures. All of that plays a role into the fouling and the buildup that that meter sees.
Like we just talked about earlier, from the thousands of meters I’ve seen, I’m going to 3 to 5X, at least, whatever that maintenance cycle’s been. A lot of my customers, especially on mag meters, at saltwater disposals, at all of these different locations, we’re on a six-month preventative maintenance program.
I’ve taken them from meters that are failing weekly. Their guys are just running around. Some of these customers have full maintenance crews that are literally 24 hours a day, seven days a week, running around cleaning meters. I’ve taken that. I’ve eliminated that for the customer.
Then, like we said, we’re on a preventative maintenance cycle, six months. We go out there. We investigate the meter. We retreat it. We roll it back in. We rock and roll for another six months.
Weldon: That sounds like a winner to me. You said that 80 percent of your work right now is with mag meters. I know that you mentioned earlier that you’ve done a lot of work with provers specifically.
Landen: Yes, sir. We treat quite a few small volume provers. We can treat them prior to them being built. We can also treat them in the field when they’re doing their three-year seal change and water draw. The big benefit that those provers see, and guys that run around with them know, is sometimes we have issues with the shaft seals leaking.
A lot of the times, that’s because foulants have stuck to that shaft internally. When that prover launches, it gets ripped through those seals. That’s where you start to see minor leaks and stuff like that. We go in there. We treat the guide rails. The guide rails that operate from the drive inside, we keep those clean.
A lot of times, they see corrosion and stuff like that. We treat those. We treat the upstream and downstream shafts. We treat everything internally. Your piston, your poppet, all of the actual assembly inside, as well as the tube itself. Every single thing that comes in contact with product is going to be treated with those small volume provers.
Weldon: I assume you’re probably doing that also. You said when the prover is assembled, you do it at that stage. Then when you prove your prover, you water draw, whichever method you’re using, any change that could potentially impact is already built into that.
Landen: That is correct. Yes, sir.
Weldon: What’s your installed base, I guess, is the way I would normally ask it if you installed…
Landen: We’re growing quite a bit right now on the prover front. Probably, I would say, around about 10, 15 provers that we’ve treated currently. It’s a big device. You don’t want to pull apart a prover unless it’s absolutely you have to.
Like I said, we’re growing that base. Customers are seeing the benefits of it, especially with minimizing the shaft seal problems and the internal seal problems as well that they sometimes come across, very rarely. We can eliminate that for customers.
Weldon: I’d be interested in hearing some more after you’ve had some time in the field and you do that through a few more provers, because I know that that background level, regardless of whether you are an operator with your own proving equipment or a service company, the last thing you need is get out there for a scheduled prove and then find out your prover has problems.
Landen: Correct.
Weldon: In the best of days, that makes for a very long day.
Landen: That is correct.
Weldon: In many cases, though, that means we’ve wasted a day. We’re going back to the shop and we’re going to tear something down.
Landen: A major success story that I’ll tell you about with those provers and really when we began to understand that, man, these provers can see the benefits of it, we had a customer in the Mont Belvieu area where they were having shaft seal leaks, I kid you not, every week. They put a brand-new shaft seal kit in there. All of a sudden, in a week, it starts to leak.
We went up there. We treated it last year. That prover is still operating with the same shaft seals that are on it. That’s one of them slam dunk. We’ve got problems. We’ve got problems. Hey, let’s try e9. They’re like, “All right. We did it. We figured it out.” It’s fun when you’re able to be a solution that a customer needs, for sure.
Weldon: Days like that make you smile and make it worth coming back to work tomorrow.
Landen: Absolutely.
Weldon: You mentioned earlier when we were talking that you all also begun to do a little bit of work with Coriolis meters?
Landen: We have been doing work with Coriolis meters. Yes, sir. We treat a ton of Coriolis meters for the South Texas region. I do come out to the Permian Basin periodically and treat a bunch of spare Coriolises in guys’ shops. Right now, we have a lot of Coriolis meters that ship directly from the manufacturer to our manufacturing facility in Boerne.
We treat it. We treat all the Coriolises that they ship and still in the boxes, and then we ship them to the actual customer. That’s been a huge added benefit to the customer, is receiving Coriolis meters that are pretreated, ready for those process conditions we talked about earlier, and you know you’re getting the e9 success that that meter is going to experience.
It’s just a great deal for the customer to be able to ship it directly to us, know it’s clean and treated properly, and then you end up with a brand-new e9-treated Coriolis meter.
Weldon: Are these predominantly Coriolises in liquid service and crude service?
Landen: They are. Yes, sir. Most of them are on LACT units and stuff like that. Yes, sir.
Weldon: You keep saying South Texas. Has South Texas just seen the light during a revival, or have you just not beat the panhandle into submission yet?
Landen: We’re getting there with them. I agree. It’s definitely not what it used to be, for sure. We’re still doing quite a bit of work down there.
Weldon: Good to hear that. Mag meters, slam dunk. Coriolis meters, slam dunk, especially if the manufacturers are shipping directly to you.
Landen: Absolutely.
Weldon: Doing some stuff with LACT meters. That’s great. Let’s not forget the folks I deal with that my podcast is pointed toward. The oil and gas management folks, a lot of those guys in the upstream and a few of them in the midstream process of gathering world, they’re concerned with that level measurement, which is where you got started. If you can fix fouling on probes, that’s great.
What about outside of those realms? Things that come to my mind is that every technology out there, every new technology we have in the measurement world, one of the selling points of that technology has been, “We’re going to reduce or eliminate maintenance. You’re not going to have to test it as often. You’re not going to have to prove it as often. You’re not going to have to clean it as often.”
Of course, in the early days of ultrasonic meters, “Oh, we’re going to sell you this meter. You’ll never need to test it. You’ll never need to calibrate it.” It took us about five years, seven years of getting a big installed space to all of a sudden decide, “Wait a minute, these meters are fouling on the inside.”
Not just are the transducers becoming so fouled that the gains get out of whack, but we’re actually building up inside of these meters. Whether it’s a mag meter or an ultrasonic meter, the diameter of that hole is what makes a difference. If we build up crud on that, that impacts it.
Landen: Correct.
Weldon: Even going back further than that, I really started out in the Permian Basin over a bunch of assets that did gathering and processing. The black powder in that world build up even in orifice meter chips, in everything. That black powder, that oxides in H2S, CO2 cause, whatever an analysis is of it, that buildup of black powder is definitely an issue.
Landen: 100 percent.
Weldon: In orifice measurement, very simply, we get salt deposits. Even on the orifice plate itself, we get our paraffin deposits. It sounds to me, Landen, like there’s some potential there.
Landen: Absolutely.
Weldon: Seems to me like treating a batch of orifice plates used in the gathering world would be a pretty easy, a pretty safe, and a pretty low cost thing to do, just to run some trials on that. I’d be really interested to see if we couldn’t get some of my brethren out there in the midstream world interested in that.
Landen: For sure.
Weldon: Of course, when we talk custody transfer measurement, and I can see where it’s easier to get into the saltwater measurement world than the gas measurement world, simply because we have lacked a good set of standards.
Landen: Correct.
Weldon: We’re just in the process of getting those first standards specifically for that saltwater measurement. I can see my arguments. If you walked into my office in 2000, I would have bowed up and go, “Oh, wait a minute, you’re going to affect my surface roughness. You’re going to affect my flow profile. Oh, oh, oh.”
The reality of it is, if you’re going to be applying your product, you’re applying your product where the customer already knows there’s a problem.
Landen: 100 percent.
Weldon: Do I want some minuscule molecular level change and I made my orifice a little bit slicker or I made my meter tube a little bit smoother? Are we going to worry about that as opposed to the 10 thousandths of black oxide or the salt blocking three quarters of the orifice hole?
Landen: Absolutely. I think the ultrasonics are going to see the exact same benefit that the mag meters have seen, that the Coriolis meters have seen. You’re going to still see that 3 to 5X moving that maintenance cycle. For us, obviously with the gas side, is we need to have someone willing to “Let’s give this a shot.”
We have done some lab testing with an ultrasonic meter. The tests look really, really good. We reduce the air in that meter. With the new technology, like I would consider us to be, comes “We’ve got to find customers that are willing to give us a shot.”
Like you talked about, there are probably many customers out there that are dealing with the hassles of having to clean these meters. Give me a call. [laughs] Let’s do some work together. We currently have treated a thermal mass meter. I know that that is well when the thermal…with all that.
[laughter]
Landen: We’re well-versed in that. Just like I said, we need to find a customer that’s having those problems and we can provide a solution for it.
Weldon: Thermal mass meters. That makes me cringe as a gas measurement guy. That’s the best technology in some cases. A lot of that stuff being used on flare right now.
Landen: Flare is where it’s going.
Weldon: That’s a lot of interesting stuff there, Landen. What you’re already doing now is great. Just from my experience of chasing problems out there in the upstream and the gathering and processing world, it just seems to be like there’s a massive opportunity out there.
Like I said, if we went back and if you talked to me in 2005, say, trying to sell me, my first thing would be the backlash and go, “Wait a minute.” Then not too long after that, we would have been given that product to try in a few places.
Landen: I still [indecipherable] that.
Weldon: Like I said, there’s places where the problems are so bad, we know the measure is not any good to begin with. Anything we do to reduce the problems have got to make measurement.
Landen: No one wants to admit they’ve got problems. No one wants to admit that they’re having issues and stuff like that. That’s something, too. Hey, we’re there when you need us. We’re there.
Weldon: Anything you want to leave us with? Anything you’d like to talk about that I didn’t mention?
Landen: I think we touched base on just about everything. Like I said, we’re really looking forward to solving a lot of these problems on the midstream side of things. It doesn’t just have to be flow measurement. It can be any type of measurement or any oilfield device.
I’m just thankful to sell a product that I do truly believe in. I do think we’re going places. We’re helping a lot of people out. I’m excited to see what the next couple of years hold, for sure.
Weldon: I know that you’ve got some great white papers on your website.
Landen: We do.
Weldon: Tell us where to find your website. Tell us where to find you.
Landen: Yes, sir. e9treatments.com. We have a brand-new website there. You can watch videos. You can read white paper documents. You could look at product data sheets, any information that you need. Our marketing director, Sharon, has done a fantastic job with the website.
Then if you want to reach out to me, reach out to me. You’ll see my LinkedIn posts weekly, trying to get some attention out there. Feel free to call or email me. If you’ve got questions regarding it, we’ll definitely talk you through it.
[background music]
Weldon: I certainly appreciate it, Landen. This has been interesting for me. I always like new things that I don’t really know much about, and this category definitely fits this.
Landen: [laughs]
Landen: I appreciate you having me on, Weldon.
Weldon: Thanks again, sir.
Landen: Bye.
Weldon: I hope you found this episode interesting and informative. We will have Landen’s contact information, along with a full transcript of this episode, in the show notes on our website, pipelinepodcastnetwork.com.
If you have comments about the episode, questions about it, suggestions for more topics, or maybe even you would like to be on the podcast as my guest, let me know. Send me a message on LinkedIn or shoot me an email at weldon.wright@fpvprime.com.