In this episode, Russel and Andre discuss the critical factors in optimizing battery life for remote and field applications. They explore the importance of selecting the right battery chemistry, such as lead-acid versus lithium, based on the specific application needs.
The conversation covers how environmental conditions like temperature, discharge depth, and the configuration of batteries (series vs. parallel) can significantly impact battery longevity. Andre emphasizes the importance of regular testing and monitoring to ensure reliability and prevent premature failure. The episode provides practical insights for maintaining battery health and extending operational life in demanding environments.
Optimizing Battery Life Show Notes, Links, and Insider Terms
- Andre Scholtz is the Technical Director at Solarcraft. Connect with Andre on LinkedIn.
- Solarcraft, Inc. is a Houston-based full-service manufacturing company that engineers and builds industrial Solar Power Systems, Backup Power Systems, Control Panels, and Electrical Shelters for critical automation and communication.
- A thermal runaway is an incident where one exothermal process triggers other processes, finally resulting in an uncontrollable increase in temperature. This can result in the destruction of the battery or, in severe cases, also in fire.
- Parallel batteries have their capacities (measured in amp-hours) added together.
- Series batteries have their voltages added together.
- Load is the consumption of power from the instruments being used in the system.
- Online UPS is always powering the load through an inverter, providing continuous and clean power.
- Offline UPS powers the load directly from line power until it switches to the inverter during a power failure.
- Line Interactive UPS corrects minor power issues like brownouts and frequency changes while also switching to inverter power during failures.
- SCADA (Supervisory Control and Data Acquisition) is a system of software and technology that allows pipeliners to control processes locally or at remote locations.
- RTUs (Remote Telemetry Units) are electronic devices placed in the field. RTUs enable remote automation by communicating data back to the facility and taking specific action after receiving input from the facility.
- Load is the consumption of power from the instruments being used in the system.
- Base load is the amount of power made available by an energy producer to meet the demand of its consumption.
- DC Actuator: An actuator powered by direct current (DC) electricity, commonly used in applications where precise control is required, such as shutdown valves.
- Locked Rotor Current: The high current that flows when an electric motor is initially started, needed to overcome inertia and set the motor in motion.
- PLC (Programmable Logic Controller): A digital computer used in industrial automation to control machinery and processes, often involving analog and digital input/output modules.
- Pyranometer: An instrument used for measuring solar irradiance on a planar surface, providing data on the solar resource available in a specific location.
- VSAT (Very Small Aperture Terminal): A satellite communication system that serves as a two-way ground station with a small dish antenna, commonly used in remote areas to establish data connections.
- Induction Motor: An electric motor in which power is supplied to the rotor by means of electromagnetic induction from a magnetic field produced by the stator winding.
- Rectifier: A device that converts alternating current (AC) to direct current (DC), commonly used in various electronic systems.
- Multi-Phase Devices: Devices that operate with multiple phases of alternating current, common in industrial applications where precise control and power efficiency are required.
- UPS (Uninterruptible Power Supply): A device or system designed to provide a continuous and reliable power supply to connected electronic equipment during power outages or fluctuations in the electrical grid. UPS units typically incorporate a battery that is automatically engaged to supply power when the regular electrical supply is interrupted, preventing data loss and damage to sensitive devices. They are commonly used in various applications, including computer systems, data centers, and critical industrial processes, to ensure uninterrupted operation and protect against power-related issues.
Optimizing Battery Life Full Episode Transcript
Russel Treat: Welcome to the “Pipeliners Podcast,” episode 350, sponsored by Solarcraft, providing high quality engineered solutions for powering, sheltering, and operating critical field automation infrastructure. Find out more about Solarcraft at Solarcraft.net.
Announcer: The Pipeliners Podcast, where professionals, bubba geeks, and industry insiders share their knowledge and experience about technology, projects, and pipeline operations. Now, your host, Russel Treat.
Russel: Thanks for listening to the Pipeliners Podcast. I appreciate you taking the time, and to show the appreciation, we give away a customized YETI tumbler to one listener every episode. This week, our winner is Dan Flodin with Alyeska Pipeline. Congratulations, Dan, your YETI’s on its way. To learn how you can win this prize, stick around till the end of the episode.
This week, we welcome back Andre Scholtz from Solarcraft, and we’ll be discussing optimizing battery life in remote systems. Andre, welcome back to the Pipeliners podcast.
Andre Scholtz: How are you doing, sir?
Russel: I’m doing great. I’m doing well. As I always do why don’t you introduce yourself? Tell us who you are and who you’re with and what you do.
Andre: My name is Andre Scholtz. I’m the technical director of Solarcraft. We mainly build remote installations where we integrate people’s control systems with power systems for the oil and gas industry. Maybe 75, 80 percent of our industry is midstream pipeline. Sorry, revenue.
In my role as technical director I’m head of the QAQC department. I also hit up the sort of SME work we have to do with the salespeople as we bring in new work to determine, what is it that needs to be made. That’s in a nutshell what I do.
Russel: We’ve already done a couple of episodes and we’re doing a whole series. We’ve covered some information about building systems and building UPSs. What I wanted to talk to you about this session is optimizing battery life.
I think one of the things, for me having a notional understanding of this type of stuff is that I know the technology around batteries is changing very, very quickly, and when you’re building an application, it’s not as simple as pick a battery and plug it in. There’s more that needs to go into it that.
What are the key considerations people ought to be thinking about when they’re looking at batteries and they’re trying to figure out how to get the optimal life out of a set of batteries?
Andre: That’s yet another one of those loaded questions. It justifies a podcast I feel. What you have to add to the question of how do you optimize battery life is for its intended purpose.
A battery that you would put in a car whose main purpose is to crank the engine and keep some lights and bits going when you waiting for the wife to finish the shopping and you don’t want to idle the car is very different from what do you put out on a pole in the desert to maintain a radio.
You wouldn’t use the same type of battery at all, and the considerations for how to prolong the life of that battery is very different. The place to start is, what is the application, what’s the intended use of the battery, select the correct chemistry for it, and then you roll out what do you do to make this battery last longest for what it’s intended deployment is.
Russel: Andre, you mentioned battery chemistry. What are the battery chemistries, and what do I need to know about those as it relates to optimizing my battery life for a particular application?
Andre: The two biggest chemistries that people are talking about these days is lead acid batteries versus lithium batteries. Each of those have some differences among them. Lead acid batteries, for instance, could be flooded batteries or valve regulated batteries. Lithium batteries may be lithium ion or lithium iron phosphate batteries.
You would usually use a lead acid battery when your installation may be subject to really cold weather. Lithium batteries are not that happy charging under really cold conditions. Lithium batteries have the advantage that they are very light and they can take a very large charge current. You may want to use those in applications that are mobile or have requirements for very short charging times.
Russel: Right. In my experience, most of the stuff that you find around field automation and automation control systems tends to be lead acid versus lithium. What’s the reason for that? Why is lead acid preferable in general? I know there’s reasons, but in general, why is lead acid preferable?
Andre: Out of the 10 reasons, I reckon the top 2 is cost and availability. They are more expensive. If property deployed, a lead acid battery can live very, very long. The second bestest reason is that lithium ion batteries do not like to get really cold.
In remote applications, very often in the middle of winter the batteries get below freezing. These batteries suffer to be charged when it’s that cold. You would probably rather choose a lead acid battery for that application.
Things are changing, though, these days. Some options are emerging. We’ll get into that in a little bit.
Russel: That’s one of the things I wanted to ask you about, because I know there’s a lot going on with batteries. People are looking at different things. Are there any promising new chemistries that you guys are looking at and evaluating?
Andre: Most of what we do have to be ridiculously reliable. We would tend not to deploy the newest technology as soon as it emerges. We wait selfishly to see other people make the mistakes first or watch whether new technologies are actually reliable as people use them like we would use them.
I am starting now to, for the first time, consider lithium iron phosphate for our field deployments because the charging temperature in really cold weather seems to be going lower and lower. The cost is also coming down significantly. The battery management systems are becoming cheaper and cheaper.
It’s at a tipping point. Of course, we’ll offer both for the longest time, but lithium iron phosphate, or LiFePO4-I don’t know how to say that properly–is what we would probably end up using in the field.
Russel: That’s interesting. I always find it interesting, your comment about you’re ridiculously concerned about reliability. For me and my experience, that’s so on point, because you really want these remotely deployed systems…
I want to be able to install them, and leave them, and forget about them. I don’t want to have to go out there and do much with them, if anything, to maintain them and keep them operational. That’s a really important part of the life cycle cost of this stuff.
Andre: Yes, it’s…
Russel: It costs a lot to put a person in a pickup truck and go visit a site.
Andre: Yes, it costs a lot. It’s very tempting to pay less for a system early on, but it’s very expensive to deal with the problem you’ve caused. It’s the logic a crack addict uses for this year’s financial statement. You have to look at the cost of rolling a truck out for sure.
Russel: What are some of the other considerations? We’ve talked about chemistry, talked a little bit about temperature. How does temperature play into what you need to do to optimize your battery life?
Andre: Lead acid batteries, in general, and every variant of them do not like to operate in high heat. In a place like, say, Kuwait, where it’s always 130 degree days, the batteries tend to stay really hot and die very young. If you do it properly with a set of really hot, good batteries, you can expect maybe three or four years of life on a nice, big battery bank.
How can you stretch that? One thing you could do is you could shade your entire system. Make really good use of shade. Shade is free. Batteries do not follow the temperature of the air. They’re very heavy, so they follow the average temperature between day and night. If it’s 130 during the day but 80 at night, then the average temperature of that battery will be whatever is in the middle of those two.
Keeping the batteries cool by insulating them, keeping them shaded, is the number one first thing you could do to prolong their life easily by double as opposed to putting them in a box that’s in the sun.
There are certain chemistries of lead acid batteries that they call high heat batteries, but those tend to not cycle well. In the application of a UPS, where they are always fully charged, they live long fine. Your favorite brand of battery manufacturer will have a range of high heat lead acid batteries, but don’t use those for solar applications without talking to them first.
The solar applications absolutely need to discharge and charge and discharge and charge every day. High heat batteries, that’s not their thing.
Another consideration to make them live longer, for lead acid batteries, in particular, is you have to keep an eye on how deep do you discharge them. A general rule of thumb is if you put about double the battery capacity than you need, it’ll live about four times as long. If you put three times more battery than you need, it would live nine times as long. It’s exponential like that.
Always install more battery than you need, and that way, all of it will live longer. It is the cheapest, most highest dollar per hour job that you could possibly do is put more battery than you need and keep the depth of the discharge down.
Russel: It’s actually an exponential function battery capacity versus length of life.
Andre: Yes, and that’s true for about any battery. They do get fired the harder you work them.
Russel: You also mentioned where we were teeing up this episode, the idea of unit voltage being a consideration. What is that, and how does it play into this?
Andre: That’s a big deal. One would try to keep an installation of batteries to as few parallel strings as possible. Thermal runaway is very real. It is a complicated subject that we don’t have time for here, but please go look it up on the Web, what causes it, and what the effects are.
As a rule, one way to mitigate thermal runaway in large battery banks is to keep the unit voltage low and have more series strings than parallel strings. Try never to have more than four units in parallel. If you have to have a really large battery bank, choose units with a lower voltage and get those in series rather than using smaller ones and many of them in parallel.
The lowest voltage you can get in lead acid batteries is about two volts per cell, and you can buy a 1,200 amp hour two volt battery. Nice, big thing. If you have to have a very large battery bank that is 48 volt, you would use 24 of those batteries all in series as opposed to a mix match of parallel and series of smaller denominations.
Russel: Interesting. That raises a question for me, why is parallel more of a problem than series? I’m probably not going to be able to understand the answer, so I might have to ask it twice.
Andre: It’s complicated. It rears its ugly head when you float batteries that have different chemical properties and different internal resistances and they are in parallel. A battery, and I may be saying this the wrong way around, does get warmer when it’s internal resistance climbs over time as the battery degrades.
In a parallel string, if its internal resistance is higher, it would cause them to get hotter, which means its internal resistance is climbing some more, which means it gets hotter, and pretty soon, you got a spectacular fire. In series installations, you do not have that problem. You just have the battery chemically failing, not violently, so to speak.
Russel: The other thing it’d be helpful to talk about, and we’ve alluded to this, but when you think about battery life, one of the things that you’ve mentioned in some of the other conversations we have, you got to understand the application, what do you want the battery to do, got to understand the load.
Are the considerations different when you’re looking at how I select and size batteries for something that is a constant base load versus something where I need to push a surge of energy, but the rest of the time, the batteries stay dormant?
Andre: It is less of a consideration with lead acid batteries than with lithium batteries. A lead acid battery, imagine a 100 amp hour gel battery, about the size of what fits in a car under the hood there. They are probably good for delivering about 600 or 800 amps without damage. They are made to do that. You can mount a range by touching the two terminals together. Many people have seen that.
Whereas a lithium battery has a battery management system, or BMS, built into it whose job it is to balance the cells carefully within the battery–they are all in series–and also limit the charging and the discharging current.
A typical number for a 100 amp hour lithium battery is about 100 amps. Sometimes 50. You get differences like…whereas a lead acid battery, you can crank them all the way up to 500, 600, 700 amps for a little bit and they’ll do it.
When it comes to, say, a vehicle…Take the example for the battery in your car. That may be an 80 amp hour battery, but every time you start the car you have to stick about 200 amps on it to crank the starter, especially if you’ve got a big engine.
If one day you decide lithium is better than lead acid and you put a lithium 80 amp hour battery in there, its BMS would stop the discharge current at 100 amps, maybe. Pick a number. It wouldn’t be able to start the car at all.
For installations that may have short bursts of really heavy draw like, for instance, hitting the lock current on a valve actuator in the middle of nowhere, you would probably want to select a lead acid battery. Otherwise, you would have to put a tremendous amount of lithium batteries out there to be able to deliver that current.
There are other lithium batteries that are fine with heavy current such as ones you find in vehicles, but at the moment they’re not practical for remote installations.
Russel: Interesting. The last thing I want to talk to you about is testing. How does testing play into optimizing battery life?
Andre: I’ll digress just for a second there. When you install a battery bank, it’s very important that all the batteries, if there aren’t multiples of them, say four or eight batteries at a site, that they all come from the same batch. You’ve bought them all at the same time. They have about the same age. Not about. Strive for exactly the same age. Don’t replace some of them.
What happens is over time, as batteries degrade, they chemically change where they may not be able to deliver their rated current anymore. Also, their internal resistance as they sulfate and age a bit, may not be the same anymore.
A healthy thing to do if you love your battery bank is buy yourself a battery tester that can do a cranking test on a battery and also test the internal resistance of it. You don’t necessarily have to buy the most expensive one out there. The Yellow testing equipment will sell you something for about $4,000 or $5,000. You might not need that. You just need to benchmark.
It’s a very healthy habit to, when your battery bank is new, you measure the internal resistance of these batteries and you take a Sharpie and you write on the battery the date that you measured it and what was the internal resistance number. After maybe a year, you do it again and you check, do they all still track the same after two years, three years?
By year number five, you may notice that one of them, because it’ll always be one, will start going south. You will see it where when you pull a large current on him, his voltage drops way lower than his brethren. Also, that battery, you will notice, will have a higher internal resistance than the other guys he’s with. Meters like that are not expensive.
If you have multiple installations with batteries, just buy a tester that can do a cranking test and a internal resistance test. Test your batteries, give them numbers, write their number, and watch, do they track the same? When you see one of them going bad, if it’s early on, replace that guy. If it’s after seven or eight years, replace the entire bank.
One more thing is a solar installation, if properly executed and the batteries stay nice and cool, should be good for about six or seven years. A UPS, if you do it properly, should be well over 10 years. You don’t necessarily have to test really hard in the first couple of years. You may want to leave it for later.
Russel: What happens if I take a five year old, six year old battery bank and I’ve got one battery that’s going bad and I replace that one battery with a new one? What does that do? What is the adverse effect of that?
Andre: There’s a very interesting analogy for that. Imagine if you build yourself a little manifold from little pipes. Let’s say, one long pipe that you weld four little pipes into, and you close it off, so now you’ve got a manifold. You put a new balloon that came from the same packet on each of these little tubes coming out of that pipe.
This is a silly analogy, forgive me. You’ll blow in one side of the pipe and you’ll notice that all four balloons will inflate at the same rate. You’ll have to blow pretty hard. If you leave them inflated like that for a period of time and you deflate them, you’ll notice they don’t return to their exact shape when you took them out of the packet. They’re going to look a little bit more limp.
When you reinflate them, they’ll still all go at the same rate. You can now inflate and reinflate this balloon array of yours, but soon, one will pop, or something will happen. If you then take a new balloon out of a packet and stick it in the old one’s place, he is tighter.
You will find that when you blow on the one end of the tube, that guy will not inflate at all, but the remaining three, which are nice and limp by now, will over inflate. All four of them will now be out of your spec.
In terms of batteries, one new battery, especially in a series string, the new one will always have the lower voltage, and the old ones will always go to a higher voltage, and both of them are out of spec now.
The charger thinks they are all at the float voltage, so he doesn’t care. Meantime, both of those just die early. You’re better off replacing the entire array of batteries rather than just one.
Russel: Basically, what happens is if you put a new battery in with a bunch of old ones, you kill all of them quicker.
Andre: You kill all of them.
Russel: That’s the net outcome of that conversation, right?
Andre: That’s right.
Russel: You kill all of them quicker. You kill the old one’s quicker because you’re overcharging them, and you kill the new one quicker because you’re undercharging it.
Andre: Yes. I’ll come up with a better story for that one day, but till then, it’ll be the balloons.
Russel: It’s actually a really good illustration. It helps me visualize it. It’s really good. Look, we’ve come to the end of the time for this conversation. We’ll go ahead and wrap this up. I want to tell you, I want to try and summarize, if you will, considerations for battery life.
The first is, select the right chemistry for the application, and we talked a little bit about one of those, some of those considerations are. Typically for most of what we do and remote operations, you’re probably going to be looking at lead acid as the desired type of battery.
Secondly, look at how you’re discharging those batteries, how hard you’re working them. More batteries in the bank will cause all the batteries to last longer. Thirdly hook them in series if you can. Then lastly as you get to the end of life, with lead acid, probably at the four year point or so, start going out there and monitoring those batteries so you know when to replace them.
Andre: I think you nailed it.
Russel: Yes. Or I guess you could also put that into your automation system and automate the process of measuring that stuff.
Andre: You can. Yes.
Russel: Yeah. Interesting.
Andre: Thank you.
Russel: How did I do that? Did I do a pretty good summary there?
Andre: Yes. I think you nailed it.
Russel: All right. Look, we’ll pick this up with another conversation. What we’re going to talk about next is powering remote valves, picking up on an episode we did a while back and adding to it.
Andre: Nice. Thank you very much.
Russel: I hope you enjoyed this week’s episode of the Pipeliners Podcast and our conversation with Andre. Just a reminder, before you go, you should register to win our customized Pipeliners Podcast YETI tumbler. Simply visit PipelinePodcastNetwork.com/Win and enter yourself in the drawing.
If you would like to support this podcast, please leave a review on Apple Podcasts, Google Play, or wherever you happen to listen. You can find instructions at PipelinePodcastNetwork.com.
If you have ideas, questions, or topics you’d be interested in, please let me know on the contact us page at PipelinePodcastNetwork.com, or reach out to me on LinkedIn. Thanks for listening. I’ll talk to you next week.
Transcription by CastingWords