This episode of the Oil & Gas Measurement Podcast breaks down the complexities of Renewable Natural Gas (RNG) sampling and analysis, focusing on the challenges posed by trace contaminants and the importance of accurate testing. Experts Diane Saber and Rubin Bennett discuss the critical need for proper sampling procedures, equipment, and specifications to ensure pipeline integrity and end-user safety, highlighting the significant financial and operational risks associated with inadequate analysis.
RNG Sampling Challenges Show Notes, Links, and Insider Terms
- Diane Saber is the President of ReeThink. Connect with Diane on LinkedIn.
- ReeThink is a high talent research and consulting company devoted to renewable energy and environmental issues specific to the natural gas industry, specializing in trace constituent analysis in natural gas, biogas, RNG and other natural gas products.
- Bennett Rubin is the Director of Sales and Business Development at Ohio Lumex Co, Inc. Connect with Bennett on LinkedIn.
- Bio-Methane or Biomethane is a fuel produced by “upgrading”, or purifying the biogas, into a renewable product that is interchangeable with natural gas.
- BioGas is produced by anaerobic digestion of organic matter, such as dead plant and animal material, manure, sewage, and organic waste in an oxygen-free environment. The natural bacterial decomposition of organic matter releases large amounts of methane, carbon dioxide, and other gasses such as hydrogen sulfide. By capturing the escaping gasses, greenhouse gas emissions to the atmosphere are reduced. After purification and dehydration, biogas is interchangeable with natural gas.
- “ManufacturedGas” / “Town Gas” / “Coal Gas” are used somewhat interchangeably to refer to synthetic fuel gasses produced by the gasification of combustible materials, usually coal, but also wood and oil. Manufacture Gas was important for lighting, heating, and cooking purposes throughout most of the 19th century and the first half of the 20th century. The fuel gasses generated were mixtures of many chemical substances, including hydrogen, methane, carbon monoxide and ethylene, and could be burnt for heating and lighting purposes. Coal gas, for example, also contains significant quantities of unwanted sulfur and ammonia compounds, as well as heavy hydrocarbons, and so the manufactured fuel gasses needed to be purified before they could be used.
- North Dakota has the only remaining commercial-scale coal gasification facility in the United States that manufactures natural gas.
- Renewable Natural Gas (RNG) is natural gas that is produced by capturing and processing the gasses produced from a variety of renewable processes. The RNG must be processed and filtered to achieve pipeline-quality standards, so it becomes “interchangeable” with geo-sourced natural gas. The methane content must be concentrated to approximately 90%, inserts reduced to acceptable limits, and toxic and\or damaging contaminants removed.
- Syngas (Synthetic Gas): A fuel gas mixture consisting primarily of hydrogen, carbon monoxide, and sometimes carbon dioxide, produced from gasification of a carbon-containing fuel.
- Pipeline Integrity: The ability of a pipeline to maintain its structural and operational soundness, ensuring safe transportation of gas.
- Trace Constituents: Small quantities of compounds present in gas, which can be harmful to human health, the environment, end-use applications, or pipeline integrity.
- Siloxanes are a class of compounds having a short repeating unit of silicon and oxygen atoms (either in a chain or a ring) with organic side chains. They are not found in geologically sourced natural gas, but they are a common contaminate pervasive in RNG sourced from landfills.
- Siloxanes are non-toxic and are frequently used in food processing and preparation. They also appear in cleaning agents, cosmetics, personal care products, lubricants, car wax, and many other consumer and industrial products.
- When burned, they create silicon dioxide, which is basically sand as a hot gas. As it cools, it is deposited on the interior surfaces of engines, burners, and turbines, reducing efficiency, and eventually damaging the equipment. Even small amounts of siloxanes in the natural gas stream are damaging, since the effects are cumulative over time.
- ASTM (American Society for Testing and Materials): An international standards organization that develops and publishes voluntary consensus technical standards for a wide range of materials, products, systems, and services, including gaseous fuels.
- AGA (American Gas Association) represents companies delivering natural gas safely, reliably, and in an environmentally responsible way to help improve the quality of life for their customers every day. AGA’s mission is to provide clear value to its membership and serve as the indispensable, leading voice and facilitator on its behalf in promoting the safe, reliable, and efficient delivery of natural gas to homes and businesses across the nation.
- API (American Petroleum Institute) represents all segments of America’s oil and natural gas industry. Its nearly 600 members produce, process and distribute most of the nation’s energy. The industry supports millions of U.S. jobs and is backed by a growing grassroots movement of millions of Americans. API was formed in 1919 as a standards-setting organization. In its first 100 years, API has developed more than 800 standards to enhance operational and environmental safety, efficiency and sustainability.
- GPA (Gas Processors Association): An association that develops and publishes standards for the natural gas processing industry.
- VOCs (Volatile Organic Compounds): Organic chemicals that have a high vapor pressure at ordinary room temperature, some of which can be harmful to human health or the environment.
- Sorbent Traps: Devices used to collect gas samples by absorbing specific analytes onto a solid material.
- Impingers: Sampling devices that bubble gas through a liquid to capture analytes.
- Chain of Custody: A documented chronological history of a sample, detailing its collection, transfer, storage, and analysis, ensuring its integrity and traceability.
- Dry Gas Meters (DGMs): Instruments used to accurately measure the volume of dry gas.
- Passivated/Coated Cylinders: Gas sampling cylinders that have been treated with an inert coating to prevent reactive compounds from adhering to the cylinder walls.
- Tedlar Bags: Bags used for gas sampling, but are now less recommended due to sensitivity and stability issues.
- Summa Canisters: Vacuum-sealed stainless steel containers used for collecting gas samples, particularly for VOCs and sulfur.
- Sorbent Traps: Tubes containing material that absorbs target analytes from gas samples.
- Impingers: Sampling devices that collect gas samples by bubbling the gas through a liquid solution.
- Filters: Materials used to capture particulate matter in gas samples.
- Mylar Bags: Foil bags used for collecting samples for carbon-14 analysis.
- Hygrometers: Instruments used to measure the moisture content of gas.
- EPA Method 29: A method for determining metals in emissions.
- 45Z Tax Credit: A tax credit from the IRS for the production of qualified clean fuels.
- Pre-injection testing: Testing done prior to the injection of RNG into a pipeline.
- Post-injection testing: Testing done after the injection of RNG into a pipeline.
- Trigger levels: Concentration levels of certain contaminants that require additional testing.
- Scrubbing: The removal of unwanted components from a gas stream during sampling or processing.
RNG Sampling Challenges Full Episode Transcript
Weldon Wright: Welcome to episode 43 of the “Oil and Gas Measurement Podcast,” sponsored by EnerSys Corporation, provider of Muddy Boots field operations software, assisting oil and gas operators to implement accurate and repeatable measurement activities across their entire operation, while also simplifying data collection from the field.
Find out more about Muddy Boots at enersyscorp.com/software/muddyboots.
[background music]
Announcer: Welcome to the Oil and Gas Measurement Podcast, where measurement professionals, Bubba geeks, and gurus share their knowledge, experience and likely a tall tale or two on measurement topics for the oil and gas industry. Now your host, Weldon Wright.
Weldon: Hello, I’m your host, Weldon Wright, with FpvPrime Consulting. Today we are honored to have Diane Saber with Rethink Consulting back with us. Diane was here back in June of ’23 for an episode titled, “What is Renewable Natural Gas,” or RNG.
Today we also have Rubin Bennett, the Director of Sales and Business Development for Ohio Lumex Company. They’re both with us today. With these two, we’re going to talk RNG. RNG’s been getting a lot of attention today. It’s been ramping up, and some of the attention hadn’t been in a good way either.
We’ve had a few pipeline and distribution system “contamination issues.” Some of these have been very expensive to remediate. Some of them have been very expensive and hard to find.
This has really turned up the focus on analyzing RNG, developing specs, which is what I’m sure Diane is very heavily involved in, but also, how do we analyze those contaminants? If you’re going to analyze for them, you’re going to sample them.
In our industry, folks, let’s face it, sometimes we’re challenged just to grab a good spot sample in that gas pipeline when all we’re worried about is hydrocarbons. When we start worrying about these trace contaminants and sometimes pretty exotic contaminants, the sampling part gets to be really important.
Today we’re going to talk about those RNG sampling issues. Before we start, Diane, tell us a little bit about yourself and what Rethink does.
Diane Saber: Hello, Weldon. Hi, Bennett. Rethink Inc is a high-talent consulting company that deals specifically with RNG. The form of RNG that we’re most concerned about is biomethane. That’s a funny thing in the industry right now we’re calling biomethane RNG.
RNG is a catch-all phrase. As we go through time, we’re going to realize there’s many forms of renewable gases, which can be included in our pipeline network. Biomethane’s one form. There are other forms such as syngas, or synthetic gas. There can be biological methanation, and even renewable hydrogen.
Today’s focus is biomethane, which is a cleaned-up form of biogas. Rethink specializes in creating specifications, which are then used to make sure that the gas is cleaned up enough and suitable for our pipeline network, so it’s safe. It’s safe on three levels.
It’s safe to human health and the environment, which is very important, it’s safe for pipeline integrity, which pipelines really care about, and it’s safe for end users. All the customers feel that they’ve got a product that will burn cleanly and safely in their burners.
Rethink also does verification and monitoring programs. Once the gas has been created, you’ll want to make sure that it’s suitable, it meets the specification I just talked about, and it continues to meet that specification over time. Rethink does those tasks as well as helps generally when biomethane issues occur on transmission and distribution pipeline networks.
Weldon: Thanks, Diane. Bennett, do the same for us. Tell us a little bit about yourself, what do Ohio Lumex…Tell us what they do a little bit and how they fit into this RNG puzzle.
Bennett Rubin: Sure, no problem. Weldon and Diane, I’m the director of sales and business development at Ohio Lumex. We’re known as the gas analysis people. I have a somewhat unique background. I have a degree in chemical engineering from Tufts University, an MBA from Columbia. Been a successful pioneer in many industries including developing pollution control technologies at GE.
Now, at Ohio Lumex, I was brought in to expand their expertise in gas analysis beyond their historical focus on coal-fired power emissions and identify this industry, gaseous fuel analysis, initially mercury, then siloxanes, and then creating a one-stop shop destination for biogas and RNG analysis.
Right now, we do it all. We have an accredited analytical laboratory. We analyze gas samples per the methods. In addition to the easy stuff we specialize in mercury, siloxanes, metals, and biologicals. We have unique laboratories in those areas. We have a field services group that travel in North America and come onsite for sampling and instrument commissioning and training.
You don’t like emissions where there was a host of third-party…We called them stack testers. That did not exist for gaseous fuels. In the end, we actually created our own school to educate, train, and certify our own staff of technicians on the proper sampling methods and techniques for this industry.
We also design, manufacture, and rent or sell sampling equipment and supplies. Initially, we did this for us, for our field service people. Now we do that for the industry. We have a line of online continuous monitoring instrumentation. We do a lot of methods development and consulting.
Lastly, well, not lastly, I teach the RNG sampling analysis classes at the Appalachian Gas Measurement Short Course and at the Western Gas Measurement Short Course. I’m a long-term, active member of ASTM, the D03 Gaseous Fuels Committee.
I’m currently on the Executive Committee, Chair of the D03.01, which is Collection and Measurement of Gaseous Sample, and Vice Chair of the D03.06, which is Analysis of Constituents in Gaseous Fuels. I’m happy to be here.
Weldon: We are great to have you here also. Some of our listeners may not be as familiar with some of the other standards bodies out there. We typically talk about AGA, API, and GPA here.
The work that you’re doing with ASTM is probably because the pipelines haven’t picked up this issue as mainstream. It’s a bigger issue than just pipelines, but our pipelines and distribution systems are right in the middle of those discussions.
Diane, you mentioned earlier, as you were telling us a little bit about yourself and what you do, you mentioned that much of this current concern is around biomethane. I’d like for you to visit with us just a little bit more about that.
Biomethane is not biomethane either just because it’s biomethane. There are some sources that are a much bigger concern to us than other sources. Tell us a little bit about that and what goes on with the different types of sources.
Diane: Biomethane is a cleaned product, but the sources of the biogas which are used for making biomethane are extremely varied. They can be sorted from pretty clean sources, all the way to pretty dirty sources.
The clean sources might include manure from animal waste, could be agricultural waste or what’s called industrial-grade food waste. That’s food products which are not acceptable to be sold to the public, but they’ve not been interfaced with the public yet either. They’re considered quite clean.
That’s a really clean source of biogas because the level of what are called trace constituents, or small quantities of compounds that are harmful to, once again, human health, the environment, end-use applications, or the pipeline, they don’t exist in those sources, or extremely low levels are found in those sources.
However, on the other end of the spectrum is the sources of landfill gas or the sludge which is at the bottom of wastewater treatment facilities, which has then been digested. As a microbiologist, I’m concerned about that.
I look at the sorts of products that are found after a biogas, an organic compound, has been digested or completely broken down. Sometimes, in landfill gas, it has nothing to do with microbiology. It’s just volatiles that are found in the landfill gas.
You think of it this way. Anything that we’ve ever thrown out in our life, thrown down the sink, out in the garbage, or just as waste, potentially could come back up as biogas again. It has nothing to do with degradation of organic compounds. Those are the elements that I’m mostly concerned about.
If we break that down a little further, they might be compounds that have metals associated with them, such as mercury or arsenic or copper, or another compound that’s commonly found. Frankly, Americans love it. It’s the compound siloxane.
Siloxane is a compound or a chemical which is used a lot in North America, particularly United States, because we like that shiny quality in the products we use. It’s found in cleaning products and cosmetics. It can be found in paints. It can be found in a wide variety of sources.
Siloxane is really inert to human health and the environment and a pipeline, but when it’s combusted, it forms a silica, or a glassy appearance, on top of the orifice, the burner tip. It can really be harmful to the end user.
We have a wide variety of sources of biogas. We have to be careful when we’re looking at cleaning the gas up. We want to make sure that we clean it up to the specification I talked about earlier. Specifications are created so that we know that that gas is safe to be included in the pipeline system. To do that, we have to test.
Weldon: Great background for us, Diane. Thank you so much for that. I know you and I have had other conversations with it. Quite a bit of that episode you did with me back in ’23 was around performing that definition.
Anybody that wants to learn a little more about that, go to the website. You can go back and find that previous episode. Was it June? I said it earlier, and I’ve forgotten it already. I think it was about June of ’23. It’ll give you a lot more background about that.
Bennett, can you discuss with us some of these specific contaminants and what their challenges is? My listener base is extremely familiar with the standard C6+ analysis that we grab, spot samples, composite samples.
Maybe we have an online, again, in air quotes, chromatograph at a big custody transfer site. We’re analyzing for those hydrocarbons, CO2, nitrogen, maybe/maybe not water vapor, and not much else. Over the years, that’s really been what’s been the concern of our pipelines and our distribution systems.
Now, as we get into some of these…I love Diane’s nice word for it, trace constituents. I would call those contaminants most of the time, but OK, we’ll call it constituents. Tell us, what are the specific things that we should be looking for that can cause problems? What is that analytical process? What does the sampling process look like? What are we involved in all that?
Bennett: You mentioned what I call the major gases. That’s a fairly typical, straightforward collection in a high-pressure cylinder. People are pretty familiar with that. When you’re getting down to these trace constituents or contaminants, it’s very different.
The objective is to collect a sample that is representative of the pipeline gas, prevent contamination or scrubbing — those are both different but very important — and keep that sample stable until it gets to the laboratory for analysis.
Again, beyond that familiar major gas analysis, we’re talking about sometimes these compounds are down to single-digit ppb, parts per billion. This makes the job very complex. We generally group the sampling into a couple of categories, generally six or seven.
You mentioned the grab samples for hydrocarbons. That’s typically in a high-pressure cylinder. That’s generally the default method for that, for major gases, sulfur and halocarbons. The key there is the cylinders have to be what we call passivated or coated with an inert coating.
Things like sulfur compounds are very reactive with metal. You’ll definitely get scrubbing of your sulfur compounds if you don’t do that correctly. People sometimes don’t flush the cylinder enough times and then don’t get a representative sample.
Then there’s the old Tedlar bags. Those are not really recommended anymore in the industry. They have limited sensitivity and stability. There’s potential for valve contamination. There’s lubricants in the valve.
A lot of those have siloxanes, silicon-base compounds, in them that are going to contaminate the sample. Hydrogen, which is important these days, passes through a Tedlar bag by the time it typically gets to the laboratory for analysis.
Then you have what look like bowling balls or Summa canisters. Those are under a vacuum. That vacuum helps keep some compounds stable. That’s what you need for volatile organic compounds, what you might hear called VOCs.
Then also, if you’re sampling a raw biogas that has high moisture and higher oxygen, you need to keep that moisture in the gas phase. That vacuum does that. If you’re looking to analyze sulfur in a raw biogas, you need to do it under a high-vacuum Summa canister. Otherwise the sulfur will disappear.
Sorbent traps are what we recommend for most analytes, these contaminants. They’re extremely stable and sensitive. It’s a non-hazardous shipment. You’re just passing gas through a glass tube. That material absorbs the mass. You’re just shipping the mass.
If you think about it, if you pass gas through that for a half an hour at a half a liter per minute, you’re sampling the equivalent of 15 liters of gas. You can get down to really sensitive areas. Mercury, siloxanes, ammonia, PCBs, pesticides, metals, NDPA, radon, others, those are classic uses for sorbent traps.
Then you get into what we call impingers. For EPA Method 29, which is for metals, you’re bubbling the sample gas through liquid in impingers in an ice bath. Very complex, hazardous method, susceptible to contamination. You’re actually mixing nitric acid and hydrogen peroxide in the field.
Then you have a category called filters. That’s for when you’re trying to capture analytes that are bound to a particulate matter. If you’re looking for alpha and beta particles, which is radioactive materials from a landfill, you use a filter to capture those particles. If you’re looking to measure bacteria, those are bound to particles. If you’re looking, again, another method for metals, that’s a way of doing it.
Then we have another form of bags, which is now new in the industry for carbon 14, is a foil bag. Typically, the brand is Mylar. That’s how you collect a sample to have that analyzed for, to see if it’s actually new carbon or old carbon.
Then the last is a group of onsite measurements. You really can’t send samples to the lab. Typically, that’s when you’re required to take gas temperatures, you’re required to do check for odors, dust, and liquids.
Then moisture is the biggest version of that where you really can’t bring that to the lab to analyze. You do it in the field either with length of stain tubes, which are great for grabbing to get rough samples, but not for accuracy. Generally, we recommend either metal oxide hygrometers or chilled mirror hygrometers to get accurate measurements.
There are some common issues that really cause problems. One is, important, is the chain of custody. Every sample has to have a chain of custody. Sometimes they’re missing or not complete, and that can give you inaccurate results because you don’t have all the information necessary.
We also run into issues with volume measurements. We generally recommend dry gas meters. Sometimes your DGMs. A lot of people use flow meters. The person in the field generally is not sitting there watching the flow meter and adjusting it for the variations of flow, so you’re not getting really accurate representations of the flow.
Plus, those are calibrated for air, not for the sample gas methane, which is very different. Dry gas meters are the way to go. We have a calculator online that you can use to make the correction for the different gases, barometric pressure also, things are important.
I mentioned earlier in high pressure cylinders, we run into issues with people not flushing them correctly, so they get full sample gas. Suma canisters, there’s all these issues of you need to have a bypass going past the Suma canister so the vacuum can pull a sample into the canister.
We recommend having a flow meter on the end of the bypass so you can make sure sample is flowing. We see a lot of times people are pulling in exhaust, which is air and sending it in for analysis. We see issues with contamination and scrubbing. People using the wrong tubing material.
There are a lot of good labs out there, but they don’t understand the industry and they send instructions that say people should use silicon tubing and could contaminate for siloxanes. People are using polyurethane materials that can scrub, also siloxane materials. Really, new Teflon, PT, PTFE or passivated stainless steel is the way to go.
People reuse a sample line sometimes that also can contaminate. In another area, which people really don’t understand as regulators, if you need to lower the pressure on a line to take the sample. A lot of people use regulators and they typically cannot be cleaned effectively, and so they will either scrub or contaminate the material. We recommend needle valves that can be cleaned.
Then the reason for passivated materials is, and for example, mercury is very reactive with metal. If you don’t have a inner coated or passivated line, you’ll not see any mercury in your analysis. Similar for sulfur compounds. They will adhere to the line and you’ll need to run the sample for extremely long period of time to get an equilibrium to make sure you get the right analysis.
Then there are issues with bacteria where you need to keep the sample cold so it doesn’t breed and create more bacteria before the analysis. We run into a lot of issues on site where people want to run the gas sample of the upgrading skid, like right before we get there to do the analysis.
There’s moisture in the line and then they that breeds bacteria and they fail the analysis. By far our biggest problem is education. There’s still a perception all you need to do is send the graph sample to lab in a bag or a cylinder and that does it all. Really, we’re in a constant education process. Making sure our clients understand things, so it gets done correctly.
Weldon: I think education being the major problem, but being an understatement, even calling it the major problem there. The little spiel you just went through for the last couple of minutes with you. I wrote down notes of things I’ve never heard of.
I’m sitting here thinking, well, I’ve spent a few years teaching gas fundamentals classes. I know I once sat through our sampling — this is just for standard hydrocarbon sampling — and rolled their eyes at the amount we preach about sampling procedures, about the right equipment.
I listened to people complaining, companies complaining about the cost of some of the outrageous things we ask for, like maintaining a constant temperature in the sampling apparatus as soon as when you collect it. Those things are rough. Very honestly, our industry does not have a great rep for always doing that consistently and well.
What we talk about in a fundamentals class for standard sampling, that doesn’t even scrape the surface for most of the stuff you just talked about. If you think you’re having trouble with standard samples, folks, I don’t know how you’re going to get to sampling RNGs without some special training, a lot of special training and a lot of special equipment.
Diane, wrap us back around a little bit. We talked about what RNG is, especially biomethane. Bennett just shared some great information about some of the constituents, which I’m still calling contaminants, in the gas. He’s given us a great surface introduction to some of the sampling systems and procedures.
I would like you to wrap back around for a minute. I know a lot of your work is focused around helping customers understand existing regulations, helping pipeline companies and distribution companies write specifications for RNG. Tell us a little bit about the state of regulations and standards and what we have or lack in our contracts, if you will.
Diane: In the contract, when you’re engaging with a new producer, an RNG producer in this case, the first thing they will ask is, how clean does the gas need to be? [laughs] If it needs to be very clean, more clean than perhaps what they expect, that means they’re going to be spending more money. To be honest, everything hinges on the money.
We want to create a specification which is known to be safe for, again, human health and the environment, end-users, and the pipeline, but not so onerous that, frankly, financially, it doesn’t make much sense. It’s an interesting fulcrum.
It’s a lot of work for someone like me or on my team to go through each constituent which we find in the gas, and try to tease it back out as being known to be causing harm or not known to cause harm. Yes, there’s still questions out there.
The fact is, when we go to test it to see what the gas contains, that’s an expensive process too. Sometimes it’s a process which everyone forgets about. They like to talk about the money involved with building the RNG unit, perhaps connecting the RNG unit to their system.
Then, at the very tail end, someone brings up the fact that we need to test the gas to make sure it’s of the quality that your contract requires. Bennett talked about the major gases or the major components. That’s mostly covered in your natural gas tariff. For the most part, gas companies follow what their tariff describes. That would be in heating value, sulfur content, inert concentration and so on.
It’s those contaminants and trace constituents that are not bound in natural gas. Biomethane, or RNG, is not natural gas. It’s a form of gas. It’s a gaseous fuel which may be included in the pipeline network. We could also use the word “interchangeable.” You can interchange it without too much notice to the customer or the pipeline.
We want to make sure that that gas meets the specification which says it’s safe and, we think, creates those specification. Also included are verification and monitoring programs. The verification program, Bennett described very accurately all of the issues that are associated with both sampling and then getting that sample, correctly, to the laboratory, such as Ohio Lumex, for analysis.
It’s two steps. You’ve got to think of it as two different things which are equally important in yielding great results. Why is that important? Because a project could have a thumbs up or a thumbs down based upon the results.
Many times, we’re thinking, “Hey, there’s nothing here,” when, in fact, that’s not true. There’s stuff in the gas. You’ve just not sampled for it correctly. Those two elements are really important.
As a company, as a gas company or an RNG producer, you want to make sure that your money that you’re spending to send a crew or have your own team take the time out to do the sampling, that time is spent very wisely and all the equipment which is used for sampling is used properly.
I think of it this way. Say you suspect that you have high cholesterol. It runs in your family. You are concerned about it. You want to make sure that you’re safe, that your cholesterol is down. You go to the doctor. He’s not going to look at your throat to find whether you’ve got cholesterol by looking at the back of your throat or in your ear.
He may suggest a blood test. When you go to give blood — we’ve all had blood tests — you realize, you look down and there’s a lot of vials down there. They’re not just taking one big sample. They’re taking different samples.
That’s because, to find what they’re looking for, they go for a specific method using a specific process. Additionally, though, especially with cholesterol, they’ll say, “Have you fasted?” You have to say, “Yes, I’ve not eaten for so many hours.” That’s important too.
It’s not just the test. It’s the setup to the test. It’s all of the little pieces that then allow the doctor to send the sample to the lab. He gets results. You know that the answer is correct. If any of those in the chain are incorrect, your result is incorrect.
That’s what we struggle with in the industry. Labs like Ohio Lumex are really good once they got those samples in. Unfortunately, it’s that field part, it’s the sampling part that seems to get hung up. My verification and monitoring programs — I know Bennett understands this as well — they include the sampling method.
It’s not that we’re lacking for the sampling method. We’re lacking the expertise enabled to take the sample accurately and properly according to the method. That’s really important. That’s the edge of the discussion today. How do we take accurate samples so that we know where our results are good?
Weldon: That was a great analogy about blood tests. I never thought it that way, but it was a great way to help simplify a very, very complex thing.
Bennett, a question that I don’t think we discussed asking earlier, but it just occurred to me. When a tech goes onsite, if you have a landfill that is going to be sampled and you’re doing what I’m going to call the full gamut of tests on that landfill gas, how long is that tech going to be onsite focused only on that sampling? It’s not a five-minute procedure. Is it?
Bennett: No. It’s typically a full day of analysis. Remember, Diane mentioned the setup part of it, which is very important, making sure we have the right sampling point. Believe it or not, that’s sometimes more difficult than you think, to make sure we’re getting the proper sample at the proper point making.
Making sure you have the right fittings, the right tubing for taking the samples, and then setting up all the equipment. Again, because, as Diane mentioned, there are different methods and collection procedures for different constituents that you’re trying to measure.
One may involve putting it into a high-pressure cylinder. Another may involve the whole Summa canisters I mentioned earlier. Another could involve the impingers, filters. We’ve designed some sampling equipment to be multifaceted so you can use it for most of these at the same time, but still there’s a setup process.
Then certain utilities and pipelines may require more than one sample be run for each of those specific constituents. We may have to do multiple sampling. Again, we’ve designed some equipment so we can do more than one sample at a time.
Other clients also like to have a backup sample sometimes, in case something goes wrong. We take another sample and don’t analyze it unless it’s needed. It generally takes a full day.
It’s complicated these days, not by just the tariffs that Diane mentioned, but by also EPA, now, requirements for the renewable fuel standard and also if the client wants to get the tax credits for the IRS for — what’s it called — the 45Z.
It can run into two days, depending on the breadth and depth of sampling that’s required. Again, it’s a process. Sometimes we stay late into the night to finish things.
Weldon: A full day or more. That’s got to warp the minds of most of my listeners. First of all, you mentioned 45D. I know Diane talked quite a bit about that in the episode she did, back in ’23. There’s not much R&D being done without those tax credits. That comes built into the equation, I assume.
How often are we doing this level of sampling? I’m assuming it’s not just once before we turn the site into the pipeline. Is it?
Bennett: No. There’s groups of requirements. Generally, they group it into what’s called pre-injection testing and then post-injection. Depending, again, on the specific requirements, pre-injection could include two samples over a month, not less than two weeks apart, or it could be over two months, not less than 40 days apart, more than 40 days apart.
After you get approval for injection, typically, there’s monthly testing requirements. It can go from a couple of months to six months to a full year. Generally, that goes into quarterly testing. After quarterly testing, it goes into annual testing.
There’s typically requirements, if you fail some constituents, you may have to go back to number one and start over, again, the process. Other requirements are more sophisticated. They have different levels of testing requirements depending on the concentrations of those trace constituents — they call them trigger levels — that require additional testing, or you can get waivers to not do testing.
For example, we recommend people put in 0.2 micron filters, to capture the particles for bacteria so they will pass their bacteria testing and potentially get waivers for not having to do that in the future.
Weldon: Of course all that’s based upon the fact that whatever that equipment that was in place and operating properly for that testing has to be kept that way. We know that, just by the nature of this beast as Diane mentioned, some of our biomethane is pretty clean, but if it’s landfill, if it’s wastewater treatment plant digester, just by definition, that’s some nasty stuff to begin with.
Even with the sources that are from corn processing folks, our feedlot digesters that Diane mentioned as being fairly clean, even with those guys, the amount of CO2, the amount of moisture, the amount of other stuff is very high. The cost of these companies to clean that gas, to get it to an acceptable spec for the pipeline, it’s very high.
As Diane mentioned when she first started her little spiel about they want to know what the absolute highest acceptable level of any contaminant is because it’s dollars out of their pocket. Every bit that they scrub, every bit that they clean, every bit that they polish, that gas is more and more money.
Of course, they want to spend the least money they can to get there. These companies, many times are running on that ragged edge, and that’s when they think they’re doing good. We would like to think that all of them out there always want to do good, but we know that’s probably not the fact.
I’ll leave this open to both of you all. Can you tell us a little bit about how our pipelines and how our distribution systems get in trouble, and in some cases face some exorbitant multimillion dollar cleanup fees? How do we get there?
Bennett: One of the biggest issues we’ve seen is contamination from siloxanes. There’s been several significant events in the last 18 months in the country, and that leads to a big mess and a multimillion dollar cleanups.
Sometimes it’s just related to the pipeline not having the specific requirements for testing. Other times it’s just related to the producer not understanding the process that they’re working with and having equipment failures or media that’s been saturated. That’s the big issue that we see continually going on on the industry.
Weldon: I think it’s important for our listeners to understand one key thing about this, and Diane touched on this, and you touched on it also, Bennett. That depending on our sampling procedures, our equipment, we could scrub, we could reduce contaminants before they ever get to the lab, right?
If we’re not analyzing a representative sample, what’s in that gas, when you start talking about parts per billion, single digit parts per billion limits on some of these compounds in our gas. If you miss that and you flow gas from one of these facilities for days, months, maybe even years, and there’s trace mercury in that, or trace radioactive isotopes in it, or siloxanes.
If you’re not seeing that in analysis, you are not going to magically see it one day at the inlet into your system unless you get better procedures, a better lab, a better tech, or something like that. What happens normally is it’s a customer on the other end that says, “Hey, we’ve got a problem. You’ve destroyed our turbine compressor. You’ve destroyed our burners.”
“Oh, we detected something in the gas that’s causing a problem. We failed an emissions test. What’s in our gas?” By that time, your distribution system and your pipeline has already concentrated, saturated, and accumulated that material. The cleanups could be massive, right?
Diane: It’s a really important point, Weldon, is that if you don’t test properly, you’re not going to see what you’re looking for. The lab will send to you an accurate evaluation of your sample.
If your sample’s acquired poorly, if the technique was not done correctly, if the collection method is incorrect, if you’ve had contamination from other things that might mask that compound, you’re not going to see it. That doesn’t mean, in the future, you’re not liable for it if there’s issues down the pipeline.
The other thing that I think sometimes our industry has gotten into is feeling like if the gas is not of the quality all the time, that’s not such a big deal. We’ll just dilute it out. The fact of the matter is, that’s not necessarily the case. In fact, the more that these RNG units come onto our system, that means there is more and more RNG on our system.
If more take that attitude, we’re going to have overall quite a bit of impact, especially at the distribution level. In distribution pipelines that concept of dilution of any product entering our line is rather incorrect.
We need to be sure that the first person that receives that RNG out of the pipeline has got a very safe product. To do that, we’ve got to take accurate samples and of course, send it accurately and in the best form to a laboratory that can handle that sample. And not all labs.
Ohio Lumex, we’re very fortunate, they’re able to analyze for the wide variety of constituents that are found in RNG, but many other labs, they maybe have the capabilities to do one or two analysis. Otherwise, we need to be very careful that we’re sending it to the right place too.
Bennett: Many of the pipelines require to use approved laboratories, and they want to make sure those labs have the equipment that can get down to the sensitivity to see those trace constituents. Because if they don’t have the proper equipment, they’re not going to see that at that level.
Generally, what they don’t ask is, are the people who are doing the sampling going to be doing them accurately? They’re taking really a risk that is unnecessary. That goes back to the education process.
Instead of just requiring approved laboratories, it all should be looking into the training and the certification of the people doing the sampling. Again, that’s just something we recommend going forward. We talk to the entities about this all the time.
Weldon: I think a key difference between the sampling and analysis we’re talking about here with constituent items in our RNG, I think it’s very important for people to understand the differences of what we’re talking about here as composed to our gas quality sampling on the typical pipeline.
What we’re doing there is 90 percent of the reason we’re sampling is to determine the heating value of that gas. Now, we want to make sure there’s not too much CO2, not too much nitrogen. We don’t have a dew point or [inaudible 44:52] that is outside of pipeline specs.
Our main thing with our normally C6+ sampling, or even extended analysis sampling as we call it, that’s to determine a dollar value on the heating units and to make sure we’re within some gross specifications. If someone delivers some gas into our pipeline that’s too high CTE, BT, or heaven forbid, a little too high in O2, in the short term, that’s not a bad thing.
But we know, especially on the gathering system world where I spend a lot of time, if we let someone deliver oxygen in our pipeline, we’re degrading our pipeline very rapidly. We’re speeding up corrosion, causing corrosion within that pipeline. The same thing with H2S moisture, with acid gas, CO2. We’re damaging our pipeline.
What we’re talking about here is something on steroids that you’re not going to see until it is built up to a level where there’s already problems. It’s not just a matter now of “We shut that customer in. They won’t be delivering that high CO2 or that high moisture anymore. Once the gas gets out of the pipeline, our problem is gone.”
That’s not the case here. If we build up metals, if we build up mercury, if we build up radioisotopes or, heaven forbid, siloxanes in that pipeline, if we get them into our customers and we’ve damaged customer equipment, we could be talking about millions and millions of dollars there for a relatively low dollar value of gases that are just in the system.
Bennett: Generally, you’re trying to group those trace constituents into what’s called pipeline integrity or equipment issues and then safety. Under pipeline integrity, you’re looking at siloxanes and bacteria. Under safety, you’re looking at metals like lead and arsenic. You’re looking at mercury.
You mentioned the radioactivity, which most people, like in landfills, don’t understand there’s a naturally occurring radon gas coming up through the ground. You have to measure that differently. Then there’s the alpha and beta particles that could be in the trash that’s in the landfill. Those are particles. It’s very complex, like we talked about.
Weldon: I get the feeling we could keep on with this conversation for the next day or two possibly, but people will think the podcast has gotten a little too long if we do that. Maybe we need to get you both back at sometime in the future.
Any thoughts as we wrap this up? Along with that question, I understand the two of y’all are going to be doing some very specialized training on this type of sampling also. As you give us a little wrap-up, be sure you get in a plug for that training.
Diane: My final comments are that it’s just a very important aspect, as the gas industry is dealing more and more with these renewable products, that we test and make sure that it’s safe for our consumers and our equipment and the pipeline itself.
To do so, taking that sample accurately and in the best possible way is key to finding the best possible results from the lab. To do that, your team should be trained, whether they’re within the gas company itself. Maybe they’re people that are out in the field that will be assisting you in these projects.
Whether it is the RNG producers themselves, that they have a deep understanding of their gas product. That just doesn’t mean making it. It means testing it and verifying it, that it’s accurate against the specification.
Or, in fact, those environmental teams or those third-party groups that come out and do this gas sampling for you as an independent agent in the process. What we’d love to see in the industry is everybody’s doing the same thing.
Why is that important? It’s really important, first of all, for accurate results. Secondly, it will drive the price down. If we’re all doing the same thing, using the same equipment, using the same processes, then we can look at each other’s results and draw some good conclusions.
Because you said, Weldon, we don’t have all the money for R&D anymore. It’s up to us to understand deeply what we’re dealing with. To do that, it’s just got to be a system that works throughout.
Weldon: Bennett, anything to add to that?
Bennett: With that in mind, Diane and I have worked together to, based on, really, demand, put together a training session for classes to do just that, educate the people that Diane’s talking about. We’re starting to offer that. We have two sessions in June and another one in August.
Based on, obviously, availability, people can either come in person, to us here at Ohio Lumex, for the class or attend it virtually. We’ll be sending out information, in the near future, on that. Also, it’s available on the Ohio Lumex website, ohiolumex.com.
Weldon: I want to thank y’all for a great episode and for your time. I think our listeners are going to find this interesting. It’s probably going to wake up a few people also. Thanks again for doing the episode, folks.
[background music]
[crosstalk]
Diane: Thank you. Bye.
Bennett: Thank you. Great to be here.
Weldon: I hope you’ve enjoyed this episode as much as I enjoyed recording it. If you did, please spread the word by telling your boss, coworkers, and your industry peers about our podcast. We will have Diane’s and Bennett’s contact information, along with a full transcript of this episode, in the show notes on our website, pipelinepodcastnetwork.com.
Also, if you have comments, questions about our episodes, suggestions for new topics, or if you’d like to offer yourself up to the podcast microphone as a guest, send me a message on LinkedIn or shoot me an email at weldon.wright@fpvprime.com.